Login

Subtype

Intelligent Inverter Heat Pump R32- P10A, P10T

Certificate Holder
Guangdong PHNIX Eco-Energy Solutions Ltd.
No. 3 Tianyuan Road Dagang Town
511470 Guangdong
China
Registration number
041-K020-08
Certification Body
BRE Global Limited
Subtype title
Intelligent Inverter Heat Pump R32- P10A, P10T
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,700 kg

Certification Date
05.09.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 12
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

P10A
Configure model
Model name
P10A
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.88 kW

9.12 kW

El input

2.43 kW

3.02 kW

COP

4.06

3.02

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

125 %

Prated

7.75 kW

8.02 kW

SCOP

4.19

3.20

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.86 kW

7.09 kW

COP Tj = -7°C

2.98

2.18

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.20 kW

4.41 kW

COP Tj = +2°C

3.87

3.05

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

2.72 kW

4.54 kW

COP Tj = +7°C

5.33

4.16

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

3.01 kW

4.83 kW

COP Tj = 12°C

7.38

5.38

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

6.86 kW

7.09 kW

COP Tj = Tbiv

2.98

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.78 kW

6.27 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.53

1.67

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

50 °C

50 °C

Poff

13 W

60 W

PTO

13 W

60 W

PSB

13 W

60 W

PCK

53 W

69 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

1.75 kW

Annual energy consumption Qhe

3824 kWh

5172 kWh

P10T
Configure model
Model name
P10T
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.70 kW

9.12 kW

El input

2.18 kW

3.02 kW

COP

4.46

3.03

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

125 %

Prated

7.79 kW

7.91 kW

SCOP

4.04

3.20

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.89 kW

7.00 kW

COP Tj = -7°C

2.98

2.22

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.24 kW

4.28 kW

COP Tj = +2°C

3.72

2.94

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.29 kW

4.08 kW

COP Tj = +7°C

5.36

4.18

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

4.36 kW

4.73 kW

COP Tj = 12°C

5.82

5.84

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

6.89 kW

7.00 kW

COP Tj = Tbiv

2.98

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.73 kW

7.92 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

50 °C

50 °C

Poff

19 W

19 W

PTO

19 W

19 W

PSB

19 W

19 W

PCK

59 W

59 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.06 kW

0.00 kW

Annual energy consumption Qhe

3979 kWh

5106 kWh