Login

Subtype

DC Inverter Heat Pump R290-30

Certificate Holder
Power World Machinery Equipment Co. Ltd
No.24, The Fourth Industrial Zone, HouTing Street
Shenzhen
China
Registration number
041-K032-07
Certification Body
BRE Global Limited
Subtype title
DC Inverter Heat Pump R290-30
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,800 kg

Certification Date
30.06.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 12
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

PW030-DKZLRS-E/S
Configure model
Model name
PW030-DKZLRS-E/S
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.99 kW

4.98 kW

El input

0.98 kW

1.54 kW

COP

5.08

3.24

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

136 %

Prated

5.82 kW

5.59 kW

SCOP

4.64

3.48

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.15 kW

4.95 kW

COP Tj = -7°C

3.33

2.38

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.21 kW

3.03 kW

COP Tj = +2°C

4.55

3.34

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.29 kW

2.93 kW

COP Tj = +7°C

6.11

4.69

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.77 kW

3.66 kW

COP Tj = 12°C

7.88

6.69

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.15 kW

4.95 kW

COP Tj = Tbiv

3.33

2.38

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.84 kW

5.58 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.84

2.07

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

6 W

6 W

PTO

20 W

20 W

PSB

6 W

6 W

PCK

42 W

42 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.01 kW

Annual energy consumption Qhe

2590 kWh

3325 kWh