Login

Subtype

Air Source Heat Pump R290-12

Certificate Holder
SolarEast Heat Pump Ltd.
No.73 Defu Road
528325 Guangdong Province,
China
Registration number
041-K042-08
Certification Body
BRE Global Limited
Subtype title
Air Source Heat Pump R290-12
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,050 kg

Certification Date
17.05.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 11
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

BLN-012TC1
Configure model
Model name
BLN-012TC1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.38 kW

12.40 kW

El input

2.66 kW

4.18 kW

COP

4.66

2.97

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

67 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

148 %

Prated

9.90 kW

10.22 kW

SCOP

4.77

3.77

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.76 kW

9.04 kW

COP Tj = -7°C

3.15

2.28

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.50 kW

5.51 kW

COP Tj = +2°C

4.57

3.64

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.75 kW

3.57 kW

COP Tj = +7°C

6.20

5.11

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.27 kW

4.09 kW

COP Tj = 12°C

9.06

7.09

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.76 kW

9.04 kW

COP Tj = Tbiv

3.15

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.94 kW

9.99 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.74

2.05

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

64 °C

64 °C

Poff

13 W

13 W

PTO

38 W

38 W

PSB

13 W

13 W

PCK

83 W

83 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.23 kW

Annual energy consumption Qhe

4286 kWh

5608 kWh

BLN-012TC3
Configure model
Model name
BLN-012TC3
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.09 kW

12.49 kW

El input

2.67 kW

4.26 kW

COP

4.53

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

67 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

145 %

Prated

9.88 kW

9.93 kW

SCOP

4.74

3.70

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.74 kW

8.79 kW

COP Tj = -7°C

3.18

2.35

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.54 kW

5.38 kW

COP Tj = +2°C

4.60

3.61

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.50 kW

3.45 kW

COP Tj = +7°C

6.10

4.83

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.10 kW

3.94 kW

COP Tj = 12°C

8.18

6.57

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.74 kW

8.79 kW

COP Tj = Tbiv

3.18

2.35

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.83 kW

9.92 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.70

2.03

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

13 W

13 W

PTO

38 W

38 W

PSB

13 W

13 W

PCK

83 W

83 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.05 kW

0.01 kW

Annual energy consumption Qhe

4300 kWh

5547 kWh