Login

Subtype

Hydro 12, Hydro 16

Certificate Holder
Alpha Therm Ltd.
Nepicar House, London Road
TN15 7RS Kent
United Kingdom
Registration number
011-1W0591
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Hydro 12, Hydro 16
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,200 kg

Certification Date
14.04.2023
Testing basis
HP KEYMARK certification scheme rules V11
Generate PDF Export model CSV
  • Number of models 2

Models

Hydro 12
Configure model
Model name
Hydro 12
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

11.30 kW

El input

2.65 kW

3.73 kW

COP

4.53

3.03

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

138 %

Prated

13.00 kW

12.00 kW

SCOP

4.69

3.51

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

10.60 kW

COP Tj = -7°C

2.71

2.16

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

7.00 kW

6.50 kW

COP Tj = +2°C

4.48

3.45

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

5.60 kW

4.20 kW

COP Tj = +7°C

6.86

4.57

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

4.80 kW

4.40 kW

COP Tj = 12°C

8.95

6.12

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

11.50 kW

10.60 kW

COP Tj = Tbiv

2.71

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.00 kW

12.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.37

1.96

WTOL

65 °C

65 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5725 kWh

7051 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

110 %

COP

2.72

Heating up time

1:30 h:min

Standby power input

62.0 W

Reference hot water temperature

52.1 °C

Mixed water at 40°C

206 l

Hydro 16
Configure model
Model name
Hydro 16
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

15.00 kW

El input

3.62 kW

5.18 kW

COP

4.42

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

138 %

Prated

16.00 kW

16.00 kW

SCOP

4.48

3.53

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.15 kW

14.15 kW

COP Tj = -7°C

2.65

2.06

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

8.62 kW

8.62 kW

COP Tj = +2°C

4.11

3.31

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

5.54 kW

5.54 kW

COP Tj = +7°C

6.86

5.23

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

5.20 kW

4.49 kW

COP Tj = 12°C

8.81

6.35

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

14.15 kW

14.15 kW

COP Tj = Tbiv

2.65

2.06

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.80 kW

14.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.37

1.82

WTOL

65 °C

65 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.20 kW

2.00 kW

Annual energy consumption Qhe

7385 kWh

9379 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

110 %

COP

2.72

Heating up time

1:30 h:min

Standby power input

62.0 W

Reference hot water temperature

52.1 °C

Mixed water at 40°C

206 l