Login

Subtype

Monobloc ACHP-H series 12/H14/H16

Certificate Holder
Ningbo AUX Electric Co., Ltd
1166 Mingguang North Road
315191 Ningbo Zhejiang
China
Registration number
011-1W0587
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Monobloc ACHP-H series 12/H14/H16
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,700 kg

Certification Date
17.02.2023
Testing basis
European KEYMARK Scheme for Heat Pumps Rev. 11 (as of 2022-09)
Generate PDF Export model CSV
  • Number of models 9

Models

ACHP-H12/4R3HA-M
Configure model
Model name
ACHP-H12/4R3HA-M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.20 kW

12.00 kW

El input

2.46 kW

3.86 kW

COP

4.96

3.11

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

254 %

174 %

Prated

11.10 kW

12.50 kW

SCOP

6.20

4.36

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.90 kW

12.30 kW

COP Tj = +2°C

3.59

2.31

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.14 kW

8.04 kW

COP Tj = +7°C

5.82

3.82

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.17 kW

3.57 kW

COP Tj = 12°C

7.94

5.70

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.14 kW

8.04 kW

COP Tj = Tbiv

5.82

3.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.90 kW

12.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.59

2.31

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.20 kW

0.20 kW

Annual energy consumption Qhe

2308 kWh

3775 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

139 %

Prated

12.20 kW

12.00 kW

SCOP

4.82

3.48

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.79 kW

10.62 kW

COP Tj = -7°C

3.02

2.11

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.57 kW

6.46 kW

COP Tj = +2°C

4.83

3.43

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.22 kW

4.15 kW

COP Tj = +7°C

6.27

4.59

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.88 kW

1.85 kW

COP Tj = 12°C

9.38

6.90

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.79 kW

10.62 kW

COP Tj = Tbiv

3.02

2.11

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.10 kW

9.16 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

2.68

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.10 kW

2.84 kW

Annual energy consumption Qhe

5114 kWh

6982 kWh

ACHP-H14/4R3HA-M
Configure model
Model name
ACHP-H14/4R3HA-M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.50 kW

14.00 kW

El input

3.08 kW

4.67 kW

COP

4.71

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

259 %

178 %

Prated

12.10 kW

13.70 kW

SCOP

6.39

4.45

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.00 kW

13.60 kW

COP Tj = +2°C

3.44

2.18

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.78 kW

8.83 kW

COP Tj = +7°C

5.84

3.91

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.75 kW

4.08 kW

COP Tj = 12°C

8.25

5.90

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.78 kW

8.83 kW

COP Tj = Tbiv

5.84

3.91

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.00 kW

13.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.44

2.18

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.10 kW

0.10 kW

Annual energy consumption Qhe

2463 kWh

4037 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

137 %

Prated

14.50 kW

14.00 kW

SCOP

4.72

3.45

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.83 kW

12.38 kW

COP Tj = -7°C

3.00

2.06

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.81 kW

7.54 kW

COP Tj = +2°C

4.74

3.50

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.02 kW

4.85 kW

COP Tj = +7°C

5.82

4.33

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.23 kW

2.15 kW

COP Tj = 12°C

9.20

6.97

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.83 kW

12.38 kW

COP Tj = Tbiv

3.00

2.06

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.46 kW

10.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.04 kW

3.50 kW

Annual energy consumption Qhe

6257 kWh

8251 kWh

ACHP-H16/4R3HA-M
Configure model
Model name
ACHP-H16/4R3HA-M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.10 kW

14.00 kW

El input

3.57 kW

4.81 kW

COP

4.51

2.91

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

246 %

176 %

Prated

13.10 kW

13.80 kW

SCOP

6.07

4.35

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.97 kW

13.67 kW

COP Tj = +2°C

3.35

2.25

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

8.41 kW

8.87 kW

COP Tj = +7°C

5.31

3.84

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.87 kW

3.94 kW

COP Tj = 12°C

8.11

5.88

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.41 kW

8.87 kW

COP Tj = Tbiv

5.31

3.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.97 kW

13.67 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.35

2.25

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.13 kW

0.13 kW

Annual energy consumption Qhe

2812 kWh

4118 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

192 %

137 %

Prated

16.10 kW

14.00 kW

SCOP

4.83

3.45

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.24 kW

12.38 kW

COP Tj = -7°C

2.98

2.06

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.67 kW

7.54 kW

COP Tj = +2°C

4.70

3.50

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.57 kW

4.85 kW

COP Tj = +7°C

6.62

4.33

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.48 kW

2.15 kW

COP Tj = 12°C

8.91

6.97

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

14.24 kW

12.38 kW

COP Tj = Tbiv

2.98

2.06

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.31 kW

10.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.67

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.79 kW

3.50 kW

Annual energy consumption Qhe

6810 kWh

8251 kWh

ACHP-H12/4R3HA-M(NE)
Configure model
Model name
ACHP-H12/4R3HA-M(NE)
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.20 kW

12.00 kW

El input

2.46 kW

3.86 kW

COP

4.96

3.11

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

254 %

174 %

Prated

11.10 kW

12.50 kW

SCOP

6.20

4.36

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.90 kW

12.30 kW

COP Tj = +2°C

3.59

2.31

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.14 kW

8.04 kW

COP Tj = +7°C

5.82

3.82

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.17 kW

3.57 kW

COP Tj = 12°C

7.94

5.70

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.14 kW

8.04 kW

COP Tj = Tbiv

5.82

3.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.90 kW

12.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.59

2.31

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.20 kW

0.20 kW

Annual energy consumption Qhe

2308 kWh

3775 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

139 %

Prated

12.20 kW

12.00 kW

SCOP

4.82

3.48

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.79 kW

10.62 kW

COP Tj = -7°C

3.02

2.11

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.57 kW

6.46 kW

COP Tj = +2°C

4.83

3.43

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.22 kW

4.15 kW

COP Tj = +7°C

6.27

4.59

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.88 kW

1.85 kW

COP Tj = 12°C

9.38

6.90

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.79 kW

10.62 kW

COP Tj = Tbiv

3.02

2.11

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.10 kW

9.16 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

2.68

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.10 kW

2.84 kW

Annual energy consumption Qhe

5114 kWh

6982 kWh

ACHP-H14/4R3HA-M(NE)
Configure model
Model name
ACHP-H14/4R3HA-M(NE)
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.50 kW

14.00 kW

El input

3.08 kW

4.67 kW

COP

4.71

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

259 %

178 %

Prated

12.10 kW

13.70 kW

SCOP

6.39

4.45

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.00 kW

13.60 kW

COP Tj = +2°C

3.44

2.18

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.78 kW

8.83 kW

COP Tj = +7°C

5.84

3.91

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.75 kW

4.08 kW

COP Tj = 12°C

8.25

5.90

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.78 kW

8.83 kW

COP Tj = Tbiv

5.84

3.91

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.00 kW

13.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.44

2.18

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.10 kW

0.10 kW

Annual energy consumption Qhe

2463 kWh

4037 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

137 %

Prated

14.50 kW

14.00 kW

SCOP

4.72

3.45

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.83 kW

12.38 kW

COP Tj = -7°C

3.00

2.06

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.81 kW

7.54 kW

COP Tj = +2°C

4.74

3.50

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.02 kW

4.85 kW

COP Tj = +7°C

5.82

4.33

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.23 kW

2.15 kW

COP Tj = 12°C

9.20

6.97

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.83 kW

12.38 kW

COP Tj = Tbiv

3.00

2.06

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.46 kW

10.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.04 kW

3.50 kW

Annual energy consumption Qhe

6257 kWh

8251 kWh

ACHP-H16/4R3HA-M(NE)
Configure model
Model name
ACHP-H16/4R3HA-M(NE)
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.10 kW

14.00 kW

El input

3.57 kW

4.81 kW

COP

4.51

2.91

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

246 %

176 %

Prated

13.10 kW

13.80 kW

SCOP

6.07

4.35

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.97 kW

13.67 kW

COP Tj = +2°C

3.35

2.25

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

8.41 kW

8.87 kW

COP Tj = +7°C

5.31

3.84

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.87 kW

3.94 kW

COP Tj = 12°C

8.11

5.88

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.41 kW

8.87 kW

COP Tj = Tbiv

5.31

3.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.97 kW

13.67 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.35

2.25

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.13 kW

0.13 kW

Annual energy consumption Qhe

2812 kWh

4118 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

192 %

137 %

Prated

16.10 kW

14.00 kW

SCOP

4.83

3.45

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.24 kW

12.38 kW

COP Tj = -7°C

2.98

2.06

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.67 kW

7.54 kW

COP Tj = +2°C

4.70

3.50

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.57 kW

4.85 kW

COP Tj = +7°C

6.62

4.33

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.48 kW

2.15 kW

COP Tj = 12°C

8.91

6.97

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

14.24 kW

12.38 kW

COP Tj = Tbiv

2.98

2.06

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.31 kW

10.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.67

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.79 kW

3.50 kW

Annual energy consumption Qhe

6810 kWh

8251 kWh

ACHP-H12/5R3HA-M
Configure model
Model name
ACHP-H12/5R3HA-M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.20 kW

12.00 kW

El input

2.46 kW

3.86 kW

COP

4.96

3.11

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

254 %

174 %

Prated

11.10 kW

12.50 kW

SCOP

6.20

4.36

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.90 kW

12.30 kW

COP Tj = +2°C

3.59

2.31

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.14 kW

8.04 kW

COP Tj = +7°C

5.82

3.82

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.17 kW

3.57 kW

COP Tj = 12°C

7.94

5.70

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.14 kW

8.04 kW

COP Tj = Tbiv

5.82

3.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.90 kW

12.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.59

2.31

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.20 kW

0.20 kW

Annual energy consumption Qhe

2308 kWh

3775 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

139 %

Prated

12.20 kW

12.00 kW

SCOP

4.82

3.48

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.79 kW

10.62 kW

COP Tj = -7°C

3.02

2.11

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.57 kW

6.46 kW

COP Tj = +2°C

4.83

3.43

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.22 kW

4.15 kW

COP Tj = +7°C

6.27

4.59

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.88 kW

1.85 kW

COP Tj = 12°C

9.38

6.90

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.79 kW

10.62 kW

COP Tj = Tbiv

3.02

2.11

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.10 kW

9.16 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

2.68

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.10 kW

2.84 kW

Annual energy consumption Qhe

5114 kWh

6982 kWh

ACHP-H14/5R3HA-M
Configure model
Model name
ACHP-H14/5R3HA-M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.50 kW

14.00 kW

El input

3.08 kW

4.67 kW

COP

4.71

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

259 %

178 %

Prated

12.10 kW

13.70 kW

SCOP

6.39

4.45

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.00 kW

13.60 kW

COP Tj = +2°C

3.44

2.18

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.78 kW

8.83 kW

COP Tj = +7°C

5.84

3.91

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.75 kW

4.08 kW

COP Tj = 12°C

8.25

5.90

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.78 kW

8.83 kW

COP Tj = Tbiv

5.84

3.91

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.00 kW

13.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.44

2.18

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.10 kW

0.10 kW

Annual energy consumption Qhe

2463 kWh

4037 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

137 %

Prated

14.50 kW

14.00 kW

SCOP

4.72

3.45

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.83 kW

12.38 kW

COP Tj = -7°C

3.00

2.06

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.81 kW

7.54 kW

COP Tj = +2°C

4.74

3.50

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.02 kW

4.85 kW

COP Tj = +7°C

5.82

4.33

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.23 kW

2.15 kW

COP Tj = 12°C

9.20

6.97

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.83 kW

12.38 kW

COP Tj = Tbiv

3.00

2.06

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.46 kW

10.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.04 kW

3.50 kW

Annual energy consumption Qhe

6257 kWh

8251 kWh

ACHP-H16/5R3HA-M
Configure model
Model name
ACHP-H16/5R3HA-M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.10 kW

14.00 kW

El input

3.57 kW

4.81 kW

COP

4.51

2.91

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

246 %

176 %

Prated

13.10 kW

13.80 kW

SCOP

6.07

4.35

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.97 kW

13.67 kW

COP Tj = +2°C

3.35

2.25

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

8.41 kW

8.87 kW

COP Tj = +7°C

5.31

3.84

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.87 kW

3.94 kW

COP Tj = 12°C

8.11

5.88

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.41 kW

8.87 kW

COP Tj = Tbiv

5.31

3.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.97 kW

13.67 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.35

2.25

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.13 kW

0.13 kW

Annual energy consumption Qhe

2812 kWh

4118 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

192 %

137 %

Prated

16.10 kW

14.00 kW

SCOP

4.83

3.45

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.24 kW

12.38 kW

COP Tj = -7°C

3.04

2.06

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.67 kW

7.54 kW

COP Tj = +2°C

4.70

3.50

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.57 kW

4.85 kW

COP Tj = +7°C

6.62

4.33

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.48 kW

2.15 kW

COP Tj = 12°C

8.91

6.97

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

14.24 kW

12.38 kW

COP Tj = Tbiv

3.04

2.06

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.31 kW

10.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.67

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.79 kW

3.50 kW

Annual energy consumption Qhe

6786 kWh

8253 kWh