1,840 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.20 kW
12.00 kW
El input
2.46 kW
3.86 kW
COP
4.96
3.11
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
245 %
171 %
Prated
11.10 kW
12.50 kW
SCOP
6.20
4.36
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.90 kW
12.30 kW
COP Tj = +2°C
3.59
2.31
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.14 kW
8.04 kW
COP Tj = +7°C
5.87
3.86
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.17 kW
3.57 kW
COP Tj = 12°C
7.94
5.70
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.14 kW
8.04 kW
COP Tj = Tbiv
5.87
3.86
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.90 kW
12.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.59
2.31
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
30 W
30 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.20 kW
0.20 kW
Annual energy consumption Qhe
2391 kWh
3831 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
136 %
Prated
12.20 kW
12.00 kW
SCOP
4.82
3.48
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.79 kW
10.62 kW
COP Tj = -7°C
3.02
2.11
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.57 kW
6.46 kW
COP Tj = +2°C
4.83
3.43
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.22 kW
4.15 kW
COP Tj = +7°C
6.27
4.59
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.88 kW
1.85 kW
COP Tj = 12°C
9.38
6.90
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.79 kW
10.62 kW
COP Tj = Tbiv
3.02
2.11
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.10 kW
9.16 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.61
2.68
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
30 W
30 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.10 kW
2.84 kW
Annual energy consumption Qhe
5230 kWh
7131 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.50 kW
14.00 kW
El input
3.08 kW
4.67 kW
COP
4.71
3.00
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
253 %
175 %
Prated
12.10 kW
13.70 kW
SCOP
6.39
4.45
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.00 kW
13.60 kW
COP Tj = +2°C
3.44
2.18
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.78 kW
8.83 kW
COP Tj = +7°C
5.84
3.91
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.75 kW
4.08 kW
COP Tj = 12°C
8.25
5.90
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.78 kW
8.83 kW
COP Tj = Tbiv
5.84
3.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
13.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.44
2.18
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
30 W
30 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.10 kW
0.10 kW
Annual energy consumption Qhe
2529 kWh
4119 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
135 %
Prated
14.50 kW
14.00 kW
SCOP
4.72
3.45
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.83 kW
12.38 kW
COP Tj = -7°C
3.00
2.06
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.81 kW
7.54 kW
COP Tj = +2°C
4.74
3.50
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.02 kW
4.85 kW
COP Tj = +7°C
5.92
4.33
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.23 kW
2.15 kW
COP Tj = 12°C
9.20
6.97
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.83 kW
12.38 kW
COP Tj = Tbiv
3.00
2.06
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.46 kW
10.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.73
1.80
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
30 W
30 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.04 kW
3.50 kW
Annual energy consumption Qhe
6352 kWh
8380 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.10 kW
16.10 kW
El input
3.57 kW
5.53 kW
COP
4.51
2.91
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
240 %
174 %
Prated
13.10 kW
13.80 kW
SCOP
6.07
4.35
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.97 kW
13.67 kW
COP Tj = +2°C
3.35
2.25
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.41 kW
8.87 kW
COP Tj = +7°C
5.36
3.84
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.87 kW
3.94 kW
COP Tj = 12°C
8.11
5.88
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.41 kW
8.87 kW
COP Tj = Tbiv
5.36
3.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.97 kW
13.67 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.35
2.25
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
30 W
30 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.13 kW
0.13 kW
Annual energy consumption Qhe
2884 kWh
4184 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
135 %
Prated
16.10 kW
14.00 kW
SCOP
4.83
3.45
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
14.24 kW
12.38 kW
COP Tj = -7°C
3.04
2.06
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
8.67 kW
7.54 kW
COP Tj = +2°C
4.70
3.50
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.57 kW
4.85 kW
COP Tj = +7°C
6.62
4.33
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.48 kW
2.15 kW
COP Tj = 12°C
8.91
6.97
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
14.24 kW
12.38 kW
COP Tj = Tbiv
3.04
2.06
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.31 kW
10.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.67
1.80
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
30 W
30 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.79 kW
3.50 kW
Annual energy consumption Qhe
6892 kWh
8380 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.20 kW
12.00 kW
El input
2.44 kW
3.86 kW
COP
4.96
3.11
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
245 %
171 %
Prated
11.10 kW
12.50 kW
SCOP
6.20
4.36
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.90 kW
12.30 kW
COP Tj = +2°C
3.59
2.31
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.14 kW
8.04 kW
COP Tj = +7°C
5.87
3.86
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.17 kW
3.57 kW
COP Tj = 12°C
7.94
5.70
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.14 kW
8.04 kW
COP Tj = Tbiv
5.87
3.86
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.90 kW
12.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.59
2.31
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
30 W
30 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.20 kW
0.20 kW
Annual energy consumption Qhe
2391 kWh
3831 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
136 %
Prated
12.20 kW
12.00 kW
SCOP
4.82
3.48
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.79 kW
10.62 kW
COP Tj = -7°C
3.02
2.11
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.57 kW
6.46 kW
COP Tj = +2°C
4.83
3.43
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.22 kW
4.15 kW
COP Tj = +7°C
6.27
4.59
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.88 kW
1.85 kW
COP Tj = 12°C
9.38
6.90
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.79 kW
10.62 kW
COP Tj = Tbiv
3.02
2.11
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.10 kW
9.16 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.61
2.68
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
30 W
30 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.10 kW
2.84 kW
Annual energy consumption Qhe
5230 kWh
7131 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.50 kW
14.00 kW
El input
3.08 kW
4.67 kW
COP
4.71
3.00
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
253 %
175 %
Prated
12.10 kW
13.70 kW
SCOP
6.39
4.45
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.00 kW
13.60 kW
COP Tj = +2°C
3.44
2.18
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.78 kW
8.83 kW
COP Tj = +7°C
5.84
3.91
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.75 kW
4.08 kW
COP Tj = 12°C
8.25
5.90
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.78 kW
8.83 kW
COP Tj = Tbiv
5.84
3.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
13.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.44
2.18
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
30 W
30 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.10 kW
0.10 kW
Annual energy consumption Qhe
2529 kWh
4119 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
135 %
Prated
14.50 kW
14.00 kW
SCOP
4.72
3.45
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.83 kW
12.38 kW
COP Tj = -7°C
3.00
2.06
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.81 kW
7.54 kW
COP Tj = +2°C
4.74
3.50
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.02 kW
4.85 kW
COP Tj = +7°C
5.92
4.33
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.23 kW
2.15 kW
COP Tj = 12°C
9.20
6.97
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.83 kW
12.38 kW
COP Tj = Tbiv
3.00
2.06
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.46 kW
10.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.73
1.80
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
30 W
30 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.04 kW
3.50 kW
Annual energy consumption Qhe
6352 kWh
8380 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.10 kW
16.10 kW
El input
3.57 kW
5.53 kW
COP
4.51
2.91
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
240 %
174 %
Prated
13.10 kW
13.80 kW
SCOP
6.07
4.35
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.97 kW
13.67 kW
COP Tj = +2°C
3.35
2.25
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.41 kW
8.87 kW
COP Tj = +7°C
5.36
3.84
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.87 kW
3.94 kW
COP Tj = 12°C
8.11
5.88
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.41 kW
8.87 kW
COP Tj = Tbiv
5.36
3.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.97 kW
13.67 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.35
2.25
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
30 W
30 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.13 kW
0.13 kW
Annual energy consumption Qhe
2884 kWh
4184 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
135 %
Prated
16.10 kW
14.00 kW
SCOP
4.83
3.45
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
14.24 kW
12.38 kW
COP Tj = -7°C
3.04
2.06
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
8.67 kW
7.54 kW
COP Tj = +2°C
4.70
3.50
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.57 kW
4.85 kW
COP Tj = +7°C
6.62
4.33
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.48 kW
2.15 kW
COP Tj = 12°C
8.91
6.97
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
14.24 kW
12.38 kW
COP Tj = Tbiv
3.04
2.06
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.31 kW
10.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.67
1.80
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
30 W
30 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.79 kW
3.50 kW
Annual energy consumption Qhe
6892 kWh
8380 kWh