Login

Subtype

WPL 25 ACS

Certificate Holder
STIEBEL ELTRON GmbH & Co KG
Dr. Stiebel Straße 33
37603 Holzminden
Germany
Registration number
011-1W0492
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
WPL 25 ACS
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

5,500 kg

Certification Date
11.08.2016
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 3

Models

WPL 25 ACS
Configure model
Model name
WPL 25 ACS
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

7.52 kW

El input

1.66 kW

2.33 kW

COP

4.82

3.23

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

139 %

Prated

15.00 kW

15.00 kW

SCOP

4.53

3.55

Tbiv

-5 °C

-5 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

13.00 kW

13.26 kW

COP Tj = -7°C

3.02

2.43

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.00 kW

7.70 kW

COP Tj = +2°C

4.40

3.37

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

8.10 kW

7.90 kW

COP Tj = +7°C

5.64

4.45

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

9.10 kW

9.00 kW

COP Tj = 12°C

8.11

6.66

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.80 kW

12.40 kW

COP Tj = Tbiv

3.18

2.53

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.60 kW

13.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.87

2.28

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

65 °C

65 °C

Poff

16 W

16 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

43 W

43 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.40 kW

1.60 kW

Annual energy consumption Qhe

6839 kWh

8723 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

236 %

174 %

Prated

8.00 kW

7.00 kW

SCOP

5.97

4.44

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.90 kW

7.40 kW

COP Tj = +2°C

3.89

2.59

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

8.10 kW

7.70 kW

COP Tj = +7°C

5.10

3.60

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

9.10 kW

9.00 kW

COP Tj = 12°C

7.72

6.11

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

7.90 kW

7.40 kW

COP Tj = Tbiv

3.89

2.59

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

17.60 kW

19.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.72

2.29

WTOL

65 °C

65 °C

Poff

16 W

16 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

43 W

43 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1789 kWh

2107 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

154 %

137 %

Prated

21.00 kW

22.00 kW

SCOP

3.93

3.25

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

12.80 kW

13.50 kW

COP Tj = -7°C

3.21

2.65

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

8.10 kW

7.90 kW

COP Tj = +2°C

4.75

3.75

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

8.20 kW

8.00 kW

COP Tj = +7°C

5.95

4.86

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

9.10 kW

9.00 kW

COP Tj = 12°C

8.11

6.95

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

12.80 kW

13.50 kW

COP Tj = Tbiv

3.21

2.65

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

17.40 kW

19.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.38

WTOL

65 °C

65 °C

Poff

16 W

16 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

43 W

43 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

21.17 kW

22.26 kW

Annual energy consumption Qhe

13182 kWh

16684 kWh

Pdh Tj = -15°C (if TOL<-20°C)

17.40

19.30

COP Tj = -15°C (if TOL<-20°C)

2.80

2.38

Cdh Tj = -15 °C

0.90

0.90

WPL 25 ACS + HSBC 300 cool " Profile M"
Configure model
Model name
WPL 25 ACS + HSBC 300 cool " Profile M"
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

7.52 kW

El input

1.66 kW

2.33 kW

COP

4.82

3.23

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

139 %

Prated

15.00 kW

15.00 kW

SCOP

4.53

3.55

Tbiv

-5 °C

-5 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

13.00 kW

13.26 kW

COP Tj = -7°C

3.02

2.43

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.00 kW

7.70 kW

COP Tj = +2°C

4.40

3.37

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

8.10 kW

7.90 kW

COP Tj = +7°C

5.64

4.45

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

9.10 kW

9.00 kW

COP Tj = 12°C

8.11

6.66

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.80 kW

12.40 kW

COP Tj = Tbiv

3.18

2.53

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.60 kW

13.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.87

2.28

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

65 °C

65 °C

Poff

16 W

16 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

43 W

43 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.40 kW

1.60 kW

Annual energy consumption Qhe

6839 kWh

8723 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

M

Efficiency ηDHW

79 %

COP

1.72

Heating up time

1:53 h:min

Standby power input

79.0 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

350 l

WPL 25 ACS + HSBC 300 cool " Profile XL"
Configure model
Model name
WPL 25 ACS + HSBC 300 cool " Profile XL"
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

7.52 kW

El input

1.66 kW

2.33 kW

COP

4.82

3.23

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

139 %

Prated

15.00 kW

15.00 kW

SCOP

4.53

3.55

Tbiv

-5 °C

-5 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

13.00 kW

13.26 kW

COP Tj = -7°C

3.02

2.43

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.00 kW

7.70 kW

COP Tj = +2°C

4.40

3.37

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

8.10 kW

7.90 kW

COP Tj = +7°C

5.64

4.45

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

9.10 kW

9.00 kW

COP Tj = 12°C

8.11

6.66

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.80 kW

12.40 kW

COP Tj = Tbiv

3.18

2.53

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.60 kW

13.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.87

2.28

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

65 °C

65 °C

Poff

16 W

16 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

43 W

43 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.40 kW

1.60 kW

Annual energy consumption Qhe

6839 kWh

8723 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

111 %

COP

2.60

Heating up time

1:49 h:min

Standby power input

79.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

362 l