Login

Subtype

Monobloc ACHP-H series 04/06

Certificate Holder
Ningbo AUX Electric Co., Ltd
1166 Mingguang North Road
315191 Ningbo Zhejiang
China
Registration number
011-1W0585
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Monobloc ACHP-H series 04/06
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,050 kg

Certification Date
17.02.2023
Testing basis
European KEYMARK Scheme for Heat Pumps Rev. 11 (as of 2022-09)
Generate PDF Export model CSV
  • Number of models 4

Models

ACHP-H04/4R3HA-M
Configure model
Model name
ACHP-H04/4R3HA-M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.30 kW

4.36 kW

El input

0.83 kW

1.47 kW

COP

5.18

2.97

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

252 %

161 %

Prated

5.50 kW

5.00 kW

SCOP

5.98

3.97

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.37 kW

4.87 kW

COP Tj = +2°C

3.94

2.51

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.54 kW

3.21 kW

COP Tj = +7°C

5.82

3.62

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.57 kW

1.43 kW

COP Tj = 12°C

7.91

5.15

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.54 kW

3.21 kW

COP Tj = Tbiv

5.82

3.62

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.37 kW

4.87 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.94

2.51

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.13 kW

0.13 kW

Annual energy consumption Qhe

1151 kWh

1627 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

132 %

Prated

5.50 kW

5.50 kW

SCOP

4.96

3.34

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.87 kW

4.87 kW

COP Tj = -7°C

2.96

1.84

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.90 kW

2.96 kW

COP Tj = +2°C

4.84

3.48

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.90 kW

1.90 kW

COP Tj = +7°C

6.46

4.28

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

0.85 kW

0.85 kW

COP Tj = 12°C

9.62

6.58

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

4.87 kW

4.87 kW

COP Tj = Tbiv

2.96

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.34 kW

3.42 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.16 kW

2.08 kW

Annual energy consumption Qhe

2295 kWh

3345 kWh

ACHP-H06/4R3HA-M
Configure model
Model name
ACHP-H06/4R3HA-M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.25 kW

6.40 kW

El input

1.30 kW

2.13 kW

COP

4.81

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

162 %

Prated

6.10 kW

5.10 kW

SCOP

6.41

3.99

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.85 kW

4.85 kW

COP Tj = +2°C

3.91

2.48

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.92 kW

3.28 kW

COP Tj = +7°C

5.89

3.61

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.74 kW

1.46 kW

COP Tj = 12°C

8.20

5.29

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.92 kW

3.28 kW

COP Tj = Tbiv

5.89

3.61

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.85 kW

4.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.91

2.48

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.25 kW

0.25 kW

Annual energy consumption Qhe

1258 kWh

1652 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

136 %

Prated

6.80 kW

6.30 kW

SCOP

4.99

3.41

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.02 kW

5.57 kW

COP Tj = -7°C

2.85

2.20

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.66 kW

3.39 kW

COP Tj = +2°C

4.98

3.42

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.35 kW

2.18 kW

COP Tj = +7°C

6.38

4.36

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.05 kW

0.97 kW

COP Tj = 12°C

9.67

6.89

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.02 kW

5.57 kW

COP Tj = Tbiv

2.95

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.42 kW

4.03 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.38 kW

2.27 kW

Annual energy consumption Qhe

2818 kWh

3733 kWh

ACHP-H04/4R3HA-M(NE)
Configure model
Model name
ACHP-H04/4R3HA-M(NE)
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.30 kW

4.36 kW

El input

0.83 kW

1.47 kW

COP

5.18

2.97

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

252 %

161 %

Prated

5.50 kW

5.00 kW

SCOP

5.98

3.97

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.37 kW

4.87 kW

COP Tj = +2°C

3.94

2.51

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.54 kW

3.21 kW

COP Tj = +7°C

5.82

3.62

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.57 kW

1.43 kW

COP Tj = 12°C

7.91

5.15

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.54 kW

3.21 kW

COP Tj = Tbiv

5.82

3.62

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.37 kW

4.87 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.94

2.51

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.13 kW

0.13 kW

Annual energy consumption Qhe

1151 kWh

1627 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

132 %

Prated

5.50 kW

5.50 kW

SCOP

4.96

3.34

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.87 kW

4.87 kW

COP Tj = -7°C

2.96

1.84

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.90 kW

2.96 kW

COP Tj = +2°C

4.84

3.48

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.90 kW

1.90 kW

COP Tj = +7°C

6.46

4.28

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

0.85 kW

0.85 kW

COP Tj = 12°C

9.62

6.58

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

4.87 kW

4.87 kW

COP Tj = Tbiv

2.96

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.34 kW

3.42 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.16 kW

2.08 kW

Annual energy consumption Qhe

2295 kWh

3345 kWh

ACHP-H06/4R3HA-M(NE)
Configure model
Model name
ACHP-H06/4R3HA-M(NE)
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.25 kW

6.40 kW

El input

1.30 kW

2.13 kW

COP

4.81

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

162 %

Prated

6.10 kW

5.10 kW

SCOP

6.41

3.99

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.85 kW

4.85 kW

COP Tj = +2°C

3.91

2.48

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.92 kW

3.28 kW

COP Tj = +7°C

5.89

3.61

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.74 kW

1.46 kW

COP Tj = 12°C

8.20

5.29

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.92 kW

3.28 kW

COP Tj = Tbiv

5.89

3.61

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.85 kW

4.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.91

2.48

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.25 kW

0.25 kW

Annual energy consumption Qhe

1258 kWh

1652 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

136 %

Prated

6.80 kW

6.30 kW

SCOP

4.99

3.41

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.02 kW

5.57 kW

COP Tj = -7°C

2.85

2.20

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.66 kW

3.39 kW

COP Tj = +2°C

4.98

3.42

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.35 kW

2.18 kW

COP Tj = +7°C

6.38

4.36

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.05 kW

0.97 kW

COP Tj = 12°C

9.67

6.89

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.02 kW

5.57 kW

COP Tj = Tbiv

2.95

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.42 kW

4.03 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.38 kW

2.27 kW

Annual energy consumption Qhe

2818 kWh

3733 kWh