0,900 kg
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
9.81 kW
9.25 kW
El input
2.06 kW
3.04 kW
COP
4.76
3.05
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
198 %
147 %
Prated
11.52 kW
10.99 kW
SCOP
5.15
3.87
Tbiv
4 °C
4 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
9.74 kW
9.22 kW
COP Tj = +2°C
4.65
3.02
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
9.99 kW
9.55 kW
COP Tj = +7°C
5.05
3.57
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
10.14 kW
9.79 kW
COP Tj = 12°C
5.47
4.37
Cdh Tj = +12 °C
0.995
0.996
Pdh Tj = Tbiv
9.87 kW
9.42 kW
COP Tj = Tbiv
4.88
3.31
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.74 kW
9.22 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.65
3.02
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
65 °C
65 °C
Poff
4 W
4 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.78 kW
1.77 kW
Annual energy consumption Qhe
2990 kWh
3799 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
202 %
150 %
Prated
11.43 kW
11.29 kW
SCOP
5.24
3.94
Tbiv
-17 °C
-16 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
10.06 kW
9.59 kW
COP Tj = -7°C
5.17
3.72
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
10.13 kW
9.73 kW
COP Tj = +2°C
5.40
4.15
Cdh Tj = +2 °C
0.996
0.996
Pdh Tj = +7°C
10.15 kW
9.84 kW
COP Tj = +7°C
5.56
4.54
Cdh Tj = +7 °C
0.995
0.996
Pdh Tj = 12°C
10.15 kW
9.93 kW
COP Tj = 12°C
5.59
4.87
Cdh Tj = +12 °C
0.995
0.996
Pdh Tj = Tbiv
9.93 kW
9.50 kW
COP Tj = Tbiv
4.96
3.44
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.74 kW
9.22 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.65
3.02
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
65 °C
65 °C
Poff
4 W
4 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.69 kW
2.07 kW
Annual energy consumption Qhe
5379 kWh
7064 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
145 %
Prated
10.60 kW
11.77 kW
SCOP
5.09
3.84
Tbiv
-8 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.81 kW
9.39 kW
COP Tj = -7°C
4.78
3.26
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
10.00 kW
9.63 kW
COP Tj = +2°C
5.08
3.86
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
10.13 kW
9.76 kW
COP Tj = +7°C
5.37
4.24
Cdh Tj = +7 °C
0.996
0.996
Pdh Tj = 12°C
10.15 kW
9.88 kW
COP Tj = 12°C
5.62
4.69
Cdh Tj = +12 °C
0.995
0.996
Pdh Tj = Tbiv
9.79 kW
9.51 kW
COP Tj = Tbiv
4.73
3.44
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.74 kW
9.22 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.65
3.02
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
65 °C
65 °C
Poff
4 W
4 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.86 kW
2.55 kW
Annual energy consumption Qhe
4305 kWh
6337 kWh
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
12.55 kW
12.01 kW
El input
2.13 kW
3.18 kW
COP
5.90
3.78
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
249 %
188 %
Prated
13.75 kW
14.24 kW
SCOP
6.42
4.89
Tbiv
3 °C
4 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.76 kW
12.01 kW
COP Tj = +2°C
6.01
3.78
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
12.73 kW
12.35 kW
COP Tj = +7°C
6.33
4.50
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
12.59 kW
12.59 kW
COP Tj = 12°C
6.70
5.58
Cdh Tj = +12 °C
0.996
0.996
Pdh Tj = Tbiv
12.76 kW
12.21 kW
COP Tj = Tbiv
6.11
4.14
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.76 kW
12.01 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.01
3.78
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
65 °C
65 °C
Poff
4 W
4 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.99 kW
2.23 kW
Annual energy consumption Qhe
2862 kWh
3890 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
252 %
192 %
Prated
14.25 kW
14.10 kW
SCOP
6.50
4.99
Tbiv
-18 °C
-17 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
12.71 kW
12.40 kW
COP Tj = -7°C
6.45
4.68
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
12.62 kW
12.53 kW
COP Tj = +2°C
6.65
5.27
Cdh Tj = +2 °C
0.996
0.996
Pdh Tj = +7°C
12.54 kW
12.64 kW
COP Tj = +7°C
6.79
5.80
Cdh Tj = +7 °C
0.995
0.996
Pdh Tj = 12°C
12.52 kW
12.74 kW
COP Tj = 12°C
6.82
6.24
Cdh Tj = +12 °C
0.995
0.996
Pdh Tj = Tbiv
12.75 kW
12.25 kW
COP Tj = Tbiv
6.23
4.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.76 kW
12.01 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.01
3.78
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
65 °C
65 °C
Poff
4 W
4 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.49 kW
2.09 kW
Annual energy consumption Qhe
4301 kWh
6970 kWh
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
247 %
186 %
Prated
13.27 kW
14.46 kW
SCOP
6.38
4.85
Tbiv
-9 °C
-6 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.76 kW
12.18 kW
COP Tj = -7°C
6.14
4.08
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
12.73 kW
12.45 kW
COP Tj = +2°C
6.37
4.86
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
12.64 kW
12.55 kW
COP Tj = +7°C
6.62
5.39
Cdh Tj = +7 °C
0.996
0.996
Pdh Tj = 12°C
12.51 kW
12.69 kW
COP Tj = 12°C
6.85
5.99
Cdh Tj = +12 °C
0.995
0.996
Pdh Tj = Tbiv
12.76 kW
12.24 kW
COP Tj = Tbiv
6.05
4.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.76 kW
12.01 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.01
3.78
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
65 °C
65 °C
Poff
4 W
4 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.51 kW
2.45 kW
Annual energy consumption Qhe
4301 kWh
6164 kWh
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
9.81 kW
9.25 kW
El input
2.06 kW
3.04 kW
COP
4.76
3.05
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
44 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
198 %
147 %
Prated
11.52 kW
10.99 kW
SCOP
5.15
3.87
Tbiv
4 °C
4 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
9.74 kW
9.22 kW
COP Tj = +2°C
4.65
3.02
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
9.99 kW
9.55 kW
COP Tj = +7°C
5.05
3.57
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
10.14 kW
9.79 kW
COP Tj = 12°C
5.47
4.37
Cdh Tj = +12 °C
0.995
0.996
Pdh Tj = Tbiv
9.87 kW
9.42 kW
COP Tj = Tbiv
4.88
3.31
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.74 kW
9.22 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.65
3.02
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
65 °C
65 °C
Poff
4 W
4 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.78 kW
1.77 kW
Annual energy consumption Qhe
2990 kWh
3799 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
44 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
202 %
150 %
Prated
11.43 kW
11.29 kW
SCOP
5.24
3.94
Tbiv
-17 °C
-16 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
10.06 kW
9.59 kW
COP Tj = -7°C
5.17
3.72
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
10.13 kW
9.73 kW
COP Tj = +2°C
5.40
4.15
Cdh Tj = +2 °C
0.996
0.996
Pdh Tj = +7°C
10.15 kW
9.84 kW
COP Tj = +7°C
5.56
4.54
Cdh Tj = +7 °C
0.995
0.996
Pdh Tj = 12°C
10.15 kW
9.93 kW
COP Tj = 12°C
5.59
4.87
Cdh Tj = +12 °C
0.995
0.996
Pdh Tj = Tbiv
9.93 kW
9.50 kW
COP Tj = Tbiv
4.96
3.44
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.74 kW
9.22 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.65
3.02
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
65 °C
65 °C
Poff
4 W
4 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.69 kW
2.07 kW
Annual energy consumption Qhe
5379 kWh
7064 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
44 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
145 %
Prated
10.60 kW
11.77 kW
SCOP
5.09
3.84
Tbiv
-8 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.81 kW
9.39 kW
COP Tj = -7°C
4.78
3.26
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
10.00 kW
9.63 kW
COP Tj = +2°C
5.08
3.86
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
10.13 kW
9.76 kW
COP Tj = +7°C
5.37
4.24
Cdh Tj = +7 °C
0.996
0.996
Pdh Tj = 12°C
10.15 kW
9.88 kW
COP Tj = 12°C
5.62
4.69
Cdh Tj = +12 °C
0.995
0.996
Pdh Tj = Tbiv
9.79 kW
9.51 kW
COP Tj = Tbiv
4.73
3.44
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.74 kW
9.22 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.65
3.02
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
65 °C
65 °C
Poff
4 W
4 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.86 kW
2.55 kW
Annual energy consumption Qhe
4305 kWh
6337 kWh
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
12.55 kW
12.01 kW
El input
2.13 kW
3.18 kW
COP
5.90
3.78
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
249 %
188 %
Prated
13.75 kW
14.24 kW
SCOP
6.42
4.89
Tbiv
3 °C
4 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.76 kW
12.01 kW
COP Tj = +2°C
6.01
3.78
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
12.73 kW
12.35 kW
COP Tj = +7°C
6.33
4.50
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
12.59 kW
12.59 kW
COP Tj = 12°C
6.70
5.58
Cdh Tj = +12 °C
0.996
0.996
Pdh Tj = Tbiv
12.76 kW
12.21 kW
COP Tj = Tbiv
6.11
4.14
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.76 kW
12.01 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.01
3.78
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
65 °C
65 °C
Poff
4 W
4 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.99 kW
2.23 kW
Annual energy consumption Qhe
2862 kWh
3890 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
252 %
192 %
Prated
14.25 kW
14.10 kW
SCOP
6.50
4.99
Tbiv
-18 °C
-17 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
12.71 kW
12.40 kW
COP Tj = -7°C
6.45
4.68
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
12.62 kW
12.53 kW
COP Tj = +2°C
6.65
5.27
Cdh Tj = +2 °C
0.996
0.996
Pdh Tj = +7°C
12.54 kW
12.64 kW
COP Tj = +7°C
6.79
5.80
Cdh Tj = +7 °C
0.995
0.996
Pdh Tj = 12°C
12.52 kW
12.74 kW
COP Tj = 12°C
6.82
6.24
Cdh Tj = +12 °C
0.995
0.996
Pdh Tj = Tbiv
12.75 kW
12.25 kW
COP Tj = Tbiv
6.23
4.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.76 kW
12.01 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.01
3.78
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
65 °C
65 °C
Poff
4 W
4 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.49 kW
2.09 kW
Annual energy consumption Qhe
4301 kWh
6970 kWh
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
247 %
186 %
Prated
13.27 kW
14.46 kW
SCOP
6.38
4.85
Tbiv
-9 °C
-6 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.76 kW
12.18 kW
COP Tj = -7°C
6.14
4.08
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
12.73 kW
12.45 kW
COP Tj = +2°C
6.37
4.86
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
12.64 kW
12.55 kW
COP Tj = +7°C
6.62
5.39
Cdh Tj = +7 °C
0.996
0.996
Pdh Tj = 12°C
12.51 kW
12.69 kW
COP Tj = 12°C
6.85
5.99
Cdh Tj = +12 °C
0.995
0.996
Pdh Tj = Tbiv
12.76 kW
12.24 kW
COP Tj = Tbiv
6.05
4.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.76 kW
12.01 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.01
3.78
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
65 °C
65 °C
Poff
4 W
4 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.51 kW
2.45 kW
Annual energy consumption Qhe
4301 kWh
6164 kWh