Login

Subtype

WPE-I 10 H(W) 400 Plus

Certificate Holder
STIEBEL ELTRON GmbH & Co KG
Dr. Stiebel Straße 33
37603 Holzminden
Germany
Registration number
012-C700165 / issue 2
Certification Body
RISE CERT
Subtype title
WPE-I 10 H(W) 400 Plus
Driving energy
Electricity
Heat Pump Type
Brine/Water and Water/Water
Refrigerant
R452B
Mass of Refrigerant

0,900 kg

Certification Date
09.02.2023
Testing basis
EN 14511:2018, EN 14825:2018, EN 12102:2017.
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

WPE-I 10 HW 400 Plus
Configure model
Model name
WPE-I 10 HW 400 Plus
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

9.81 kW

9.25 kW

El input

2.06 kW

3.04 kW

COP

4.76

3.05

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

198 %

147 %

Prated

11.52 kW

10.99 kW

SCOP

5.15

3.87

Tbiv

4 °C

4 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.74 kW

9.22 kW

COP Tj = +2°C

4.65

3.02

Cdh Tj = +2 °C

0.996

0.997

Pdh Tj = +7°C

9.99 kW

9.55 kW

COP Tj = +7°C

5.05

3.57

Cdh Tj = +7 °C

0.996

0.997

Pdh Tj = 12°C

10.14 kW

9.79 kW

COP Tj = 12°C

5.47

4.37

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

9.87 kW

9.42 kW

COP Tj = Tbiv

4.88

3.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.74 kW

9.22 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.65

3.02

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.78 kW

1.77 kW

Annual energy consumption Qhe

2990 kWh

3799 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

202 %

150 %

Prated

11.43 kW

11.29 kW

SCOP

5.24

3.94

Tbiv

-17 °C

-16 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

10.06 kW

9.59 kW

COP Tj = -7°C

5.17

3.72

Cdh Tj = -7 °C

0.996

0.997

Pdh Tj = +2°C

10.13 kW

9.73 kW

COP Tj = +2°C

5.40

4.15

Cdh Tj = +2 °C

0.996

0.996

Pdh Tj = +7°C

10.15 kW

9.84 kW

COP Tj = +7°C

5.56

4.54

Cdh Tj = +7 °C

0.995

0.996

Pdh Tj = 12°C

10.15 kW

9.93 kW

COP Tj = 12°C

5.59

4.87

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

9.93 kW

9.50 kW

COP Tj = Tbiv

4.96

3.44

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.74 kW

9.22 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.65

3.02

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.69 kW

2.07 kW

Annual energy consumption Qhe

5379 kWh

7064 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

145 %

Prated

10.60 kW

11.77 kW

SCOP

5.09

3.84

Tbiv

-8 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.81 kW

9.39 kW

COP Tj = -7°C

4.78

3.26

Cdh Tj = -7 °C

0.996

0.997

Pdh Tj = +2°C

10.00 kW

9.63 kW

COP Tj = +2°C

5.08

3.86

Cdh Tj = +2 °C

0.996

0.997

Pdh Tj = +7°C

10.13 kW

9.76 kW

COP Tj = +7°C

5.37

4.24

Cdh Tj = +7 °C

0.996

0.996

Pdh Tj = 12°C

10.15 kW

9.88 kW

COP Tj = 12°C

5.62

4.69

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

9.79 kW

9.51 kW

COP Tj = Tbiv

4.73

3.44

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.74 kW

9.22 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.65

3.02

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.86 kW

2.55 kW

Annual energy consumption Qhe

4305 kWh

6337 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

12.55 kW

12.01 kW

El input

2.13 kW

3.18 kW

COP

5.90

3.78

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

249 %

188 %

Prated

13.75 kW

14.24 kW

SCOP

6.42

4.89

Tbiv

3 °C

4 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.76 kW

12.01 kW

COP Tj = +2°C

6.01

3.78

Cdh Tj = +2 °C

0.996

0.997

Pdh Tj = +7°C

12.73 kW

12.35 kW

COP Tj = +7°C

6.33

4.50

Cdh Tj = +7 °C

0.996

0.997

Pdh Tj = 12°C

12.59 kW

12.59 kW

COP Tj = 12°C

6.70

5.58

Cdh Tj = +12 °C

0.996

0.996

Pdh Tj = Tbiv

12.76 kW

12.21 kW

COP Tj = Tbiv

6.11

4.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.76 kW

12.01 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.01

3.78

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.99 kW

2.23 kW

Annual energy consumption Qhe

2862 kWh

3890 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

252 %

192 %

Prated

14.25 kW

14.10 kW

SCOP

6.50

4.99

Tbiv

-18 °C

-17 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

12.71 kW

12.40 kW

COP Tj = -7°C

6.45

4.68

Cdh Tj = -7 °C

0.996

0.997

Pdh Tj = +2°C

12.62 kW

12.53 kW

COP Tj = +2°C

6.65

5.27

Cdh Tj = +2 °C

0.996

0.996

Pdh Tj = +7°C

12.54 kW

12.64 kW

COP Tj = +7°C

6.79

5.80

Cdh Tj = +7 °C

0.995

0.996

Pdh Tj = 12°C

12.52 kW

12.74 kW

COP Tj = 12°C

6.82

6.24

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

12.75 kW

12.25 kW

COP Tj = Tbiv

6.23

4.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.76 kW

12.01 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.01

3.78

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.49 kW

2.09 kW

Annual energy consumption Qhe

4301 kWh

6970 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

247 %

186 %

Prated

13.27 kW

14.46 kW

SCOP

6.38

4.85

Tbiv

-9 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.76 kW

12.18 kW

COP Tj = -7°C

6.14

4.08

Cdh Tj = -7 °C

0.996

0.997

Pdh Tj = +2°C

12.73 kW

12.45 kW

COP Tj = +2°C

6.37

4.86

Cdh Tj = +2 °C

0.996

0.997

Pdh Tj = +7°C

12.64 kW

12.55 kW

COP Tj = +7°C

6.62

5.39

Cdh Tj = +7 °C

0.996

0.996

Pdh Tj = 12°C

12.51 kW

12.69 kW

COP Tj = 12°C

6.85

5.99

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

12.76 kW

12.24 kW

COP Tj = Tbiv

6.05

4.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.76 kW

12.01 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.01

3.78

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.51 kW

2.45 kW

Annual energy consumption Qhe

4301 kWh

6164 kWh

WPE-I 10 H 400 Plus
Configure model
Model name
WPE-I 10 H 400 Plus
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

9.81 kW

9.25 kW

El input

2.06 kW

3.04 kW

COP

4.76

3.05

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

44 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

198 %

147 %

Prated

11.52 kW

10.99 kW

SCOP

5.15

3.87

Tbiv

4 °C

4 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.74 kW

9.22 kW

COP Tj = +2°C

4.65

3.02

Cdh Tj = +2 °C

0.996

0.997

Pdh Tj = +7°C

9.99 kW

9.55 kW

COP Tj = +7°C

5.05

3.57

Cdh Tj = +7 °C

0.996

0.997

Pdh Tj = 12°C

10.14 kW

9.79 kW

COP Tj = 12°C

5.47

4.37

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

9.87 kW

9.42 kW

COP Tj = Tbiv

4.88

3.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.74 kW

9.22 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.65

3.02

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.78 kW

1.77 kW

Annual energy consumption Qhe

2990 kWh

3799 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

44 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

202 %

150 %

Prated

11.43 kW

11.29 kW

SCOP

5.24

3.94

Tbiv

-17 °C

-16 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

10.06 kW

9.59 kW

COP Tj = -7°C

5.17

3.72

Cdh Tj = -7 °C

0.996

0.997

Pdh Tj = +2°C

10.13 kW

9.73 kW

COP Tj = +2°C

5.40

4.15

Cdh Tj = +2 °C

0.996

0.996

Pdh Tj = +7°C

10.15 kW

9.84 kW

COP Tj = +7°C

5.56

4.54

Cdh Tj = +7 °C

0.995

0.996

Pdh Tj = 12°C

10.15 kW

9.93 kW

COP Tj = 12°C

5.59

4.87

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

9.93 kW

9.50 kW

COP Tj = Tbiv

4.96

3.44

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.74 kW

9.22 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.65

3.02

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.69 kW

2.07 kW

Annual energy consumption Qhe

5379 kWh

7064 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

44 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

145 %

Prated

10.60 kW

11.77 kW

SCOP

5.09

3.84

Tbiv

-8 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.81 kW

9.39 kW

COP Tj = -7°C

4.78

3.26

Cdh Tj = -7 °C

0.996

0.997

Pdh Tj = +2°C

10.00 kW

9.63 kW

COP Tj = +2°C

5.08

3.86

Cdh Tj = +2 °C

0.996

0.997

Pdh Tj = +7°C

10.13 kW

9.76 kW

COP Tj = +7°C

5.37

4.24

Cdh Tj = +7 °C

0.996

0.996

Pdh Tj = 12°C

10.15 kW

9.88 kW

COP Tj = 12°C

5.62

4.69

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

9.79 kW

9.51 kW

COP Tj = Tbiv

4.73

3.44

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.74 kW

9.22 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.65

3.02

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.86 kW

2.55 kW

Annual energy consumption Qhe

4305 kWh

6337 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

12.55 kW

12.01 kW

El input

2.13 kW

3.18 kW

COP

5.90

3.78

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

249 %

188 %

Prated

13.75 kW

14.24 kW

SCOP

6.42

4.89

Tbiv

3 °C

4 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.76 kW

12.01 kW

COP Tj = +2°C

6.01

3.78

Cdh Tj = +2 °C

0.996

0.997

Pdh Tj = +7°C

12.73 kW

12.35 kW

COP Tj = +7°C

6.33

4.50

Cdh Tj = +7 °C

0.996

0.997

Pdh Tj = 12°C

12.59 kW

12.59 kW

COP Tj = 12°C

6.70

5.58

Cdh Tj = +12 °C

0.996

0.996

Pdh Tj = Tbiv

12.76 kW

12.21 kW

COP Tj = Tbiv

6.11

4.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.76 kW

12.01 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.01

3.78

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.99 kW

2.23 kW

Annual energy consumption Qhe

2862 kWh

3890 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

252 %

192 %

Prated

14.25 kW

14.10 kW

SCOP

6.50

4.99

Tbiv

-18 °C

-17 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

12.71 kW

12.40 kW

COP Tj = -7°C

6.45

4.68

Cdh Tj = -7 °C

0.996

0.997

Pdh Tj = +2°C

12.62 kW

12.53 kW

COP Tj = +2°C

6.65

5.27

Cdh Tj = +2 °C

0.996

0.996

Pdh Tj = +7°C

12.54 kW

12.64 kW

COP Tj = +7°C

6.79

5.80

Cdh Tj = +7 °C

0.995

0.996

Pdh Tj = 12°C

12.52 kW

12.74 kW

COP Tj = 12°C

6.82

6.24

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

12.75 kW

12.25 kW

COP Tj = Tbiv

6.23

4.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.76 kW

12.01 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.01

3.78

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.49 kW

2.09 kW

Annual energy consumption Qhe

4301 kWh

6970 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

247 %

186 %

Prated

13.27 kW

14.46 kW

SCOP

6.38

4.85

Tbiv

-9 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.76 kW

12.18 kW

COP Tj = -7°C

6.14

4.08

Cdh Tj = -7 °C

0.996

0.997

Pdh Tj = +2°C

12.73 kW

12.45 kW

COP Tj = +2°C

6.37

4.86

Cdh Tj = +2 °C

0.996

0.997

Pdh Tj = +7°C

12.64 kW

12.55 kW

COP Tj = +7°C

6.62

5.39

Cdh Tj = +7 °C

0.996

0.996

Pdh Tj = 12°C

12.51 kW

12.69 kW

COP Tj = 12°C

6.85

5.99

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

12.76 kW

12.24 kW

COP Tj = Tbiv

6.05

4.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.76 kW

12.01 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.01

3.78

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.51 kW

2.45 kW

Annual energy consumption Qhe

4301 kWh

6164 kWh