Login

Subtype

WPE-I 05 H(W) 400 Plus

Certificate Holder
STIEBEL ELTRON GmbH & Co KG
Dr. Stiebel Straße 33
37603 Holzminden
Germany
Registration number
012-C700163 / issue 2
Certification Body
RISE CERT
Subtype title
WPE-I 05 H(W) 400 Plus
Driving energy
Electricity
Heat Pump Type
Brine/Water and Water/Water
Refrigerant
R452B
Mass of Refrigerant

0,575 kg

Certification Date
09.02.2023
Testing basis
EN 14511:2018, EN 14825:2018, EN 12102:2017.
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

WPE-I 05 HW 400 Plus
Configure model
Model name
WPE-I 05 HW 400 Plus
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

5.56 kW

5.00 kW

El input

1.26 kW

1.80 kW

COP

4.40

2.78

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

135 %

Prated

6.53 kW

6.00 kW

SCOP

4.78

3.58

Tbiv

4 °C

4 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.54 kW

5.00 kW

COP Tj = +2°C

4.39

2.77

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

5.63 kW

5.15 kW

COP Tj = +7°C

4.72

3.34

Cdh Tj = +7 °C

0.990

1.000

Pdh Tj = 12°C

5.71 kW

5.34 kW

COP Tj = 12°C

5.09

4.04

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

5.60 kW

5.14 kW

COP Tj = Tbiv

4.59

3.11

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.54 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.99 kW

1.00 kW

Annual energy consumption Qhe

1825 kWh

2237 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

138 %

Prated

6.26 kW

6.07 kW

SCOP

4.87

3.65

Tbiv

-18 °C

-16 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.65 kW

5.19 kW

COP Tj = -7°C

4.80

3.47

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

5.70 kW

5.29 kW

COP Tj = +2°C

5.02

3.86

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

5.73 kW

5.37 kW

COP Tj = +7°C

5.18

4.17

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

5.74 kW

5.43 kW

COP Tj = 12°C

5.22

4.40

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

5.60 kW

5.11 kW

COP Tj = Tbiv

4.60

3.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.54 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.72 kW

1.07 kW

Annual energy consumption Qhe

3170 kWh

4104 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

135 %

Prated

6.03 kW

6.33 kW

SCOP

4.74

3.56

Tbiv

-8 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.58 kW

5.14 kW

COP Tj = -7°C

4.51

3.07

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

5.64 kW

5.23 kW

COP Tj = +2°C

4.74

3.60

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

5.69 kW

5.31 kW

COP Tj = +7°C

4.99

3.94

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

5.75 kW

5.39 kW

COP Tj = 12°C

5.25

4.27

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

5.57 kW

5.12 kW

COP Tj = Tbiv

4.47

3.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.54 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.49 kW

1.33 kW

Annual energy consumption Qhe

2630 kWh

3672 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.21 kW

6.66 kW

El input

1.27 kW

1.86 kW

COP

5.70

3.57

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

238 %

177 %

Prated

7.81 kW

7.94 kW

SCOP

6.16

4.62

Tbiv

3 °C

4 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.21 kW

6.66 kW

COP Tj = +2°C

5.70

3.57

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

7.31 kW

6.93 kW

COP Tj = +7°C

6.07

4.25

Cdh Tj = +7 °C

0.990

1.000

Pdh Tj = 12°C

7.37 kW

7.19 kW

COP Tj = 12°C

6.53

5.31

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

7.25 kW

6.81 kW

COP Tj = Tbiv

5.82

3.91

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.21 kW

6.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.70

3.57

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.60 kW

1.28 kW

Annual energy consumption Qhe

1694 kWh

2299 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

243 %

181 %

Prated

8.14 kW

8.16 kW

SCOP

6.27

4.72

Tbiv

-18 °C

-16 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.34 kW

6.98 kW

COP Tj = -7°C

6.22

4.45

Cdh Tj = -7 °C

0.990

0.996

Pdh Tj = +2°C

7.36 kW

7.13 kW

COP Tj = +2°C

6.46

5.02

Cdh Tj = +2 °C

0.990

0.995

Pdh Tj = +7°C

7.37 kW

7.24 kW

COP Tj = +7°C

6.64

5.52

Cdh Tj = +7 °C

0.990

0.995

Pdh Tj = 12°C

7.37 kW

7.31 kW

COP Tj = 12°C

6.68

5.94

Cdh Tj = +12 °C

0.990

0.994

Pdh Tj = Tbiv

7.29 kW

6.87 kW

COP Tj = Tbiv

5.96

4.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.21 kW

6.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.70

3.57

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.996

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.93 kW

1.50 kW

Annual energy consumption Qhe

3199 kWh

4265 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

237 %

175 %

Prated

7.85 kW

8.07 kW

SCOP

6.12

4.58

Tbiv

-8 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.26 kW

6.78 kW

COP Tj = -7°C

5.85

3.85

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

7.32 kW

7.02 kW

COP Tj = +2°C

6.14

4.60

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

7.36 kW

7.15 kW

COP Tj = +7°C

6.43

5.12

Cdh Tj = +7 °C

0.990

1.000

Pdh Tj = 12°C

7.37 kW

7.27 kW

COP Tj = 12°C

6.71

5.70

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

7.24 kW

6.83 kW

COP Tj = Tbiv

5.80

3.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.21 kW

6.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.70

3.57

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.64 kW

1.41 kW

Annual energy consumption Qhe

2651 kWh

3641 kWh

WPE-I 05 H 400 Plus
Configure model
Model name
WPE-I 05 H 400 Plus
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

5.56 kW

5.00 kW

El input

1.26 kW

1.80 kW

COP

4.40

2.78

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

44 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

135 %

Prated

6.53 kW

6.00 kW

SCOP

4.78

3.58

Tbiv

4 °C

4 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.54 kW

5.00 kW

COP Tj = +2°C

4.39

2.77

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

5.63 kW

5.15 kW

COP Tj = +7°C

4.72

3.34

Cdh Tj = +7 °C

0.990

1.000

Pdh Tj = 12°C

5.71 kW

5.34 kW

COP Tj = 12°C

5.09

4.04

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

5.60 kW

5.14 kW

COP Tj = Tbiv

4.59

3.11

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.54 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.99 kW

1.00 kW

Annual energy consumption Qhe

1825 kWh

2237 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

44 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

138 %

Prated

6.26 kW

6.07 kW

SCOP

4.87

3.65

Tbiv

-18 °C

-16 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.65 kW

5.19 kW

COP Tj = -7°C

4.80

3.47

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

5.70 kW

5.29 kW

COP Tj = +2°C

5.02

3.86

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

5.73 kW

5.37 kW

COP Tj = +7°C

5.18

4.17

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

5.74 kW

5.43 kW

COP Tj = 12°C

5.22

4.40

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

5.60 kW

5.11 kW

COP Tj = Tbiv

4.60

3.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.54 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.72 kW

1.07 kW

Annual energy consumption Qhe

3170 kWh

4104 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

44 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

135 %

Prated

6.03 kW

6.33 kW

SCOP

4.74

3.56

Tbiv

-8 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.58 kW

5.14 kW

COP Tj = -7°C

4.51

3.07

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

5.64 kW

5.23 kW

COP Tj = +2°C

4.74

3.60

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

5.69 kW

5.31 kW

COP Tj = +7°C

4.99

3.94

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

5.75 kW

5.39 kW

COP Tj = 12°C

5.25

4.27

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

5.57 kW

5.12 kW

COP Tj = Tbiv

4.47

3.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.54 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.49 kW

1.33 kW

Annual energy consumption Qhe

2630 kWh

3672 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.21 kW

6.66 kW

El input

1.27 kW

1.86 kW

COP

5.70

3.57

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

238 %

177 %

Prated

7.81 kW

7.94 kW

SCOP

6.16

4.62

Tbiv

3 °C

4 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.21 kW

6.66 kW

COP Tj = +2°C

5.70

3.57

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

7.31 kW

6.93 kW

COP Tj = +7°C

6.07

4.25

Cdh Tj = +7 °C

0.990

1.000

Pdh Tj = 12°C

7.37 kW

7.19 kW

COP Tj = 12°C

6.53

5.31

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

7.25 kW

6.81 kW

COP Tj = Tbiv

5.82

3.91

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.21 kW

6.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.70

3.57

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.60 kW

1.28 kW

Annual energy consumption Qhe

1694 kWh

2299 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

243 %

181 %

Prated

8.14 kW

8.16 kW

SCOP

6.27

4.72

Tbiv

-18 °C

-16 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.34 kW

6.98 kW

COP Tj = -7°C

6.22

4.45

Cdh Tj = -7 °C

0.990

0.996

Pdh Tj = +2°C

7.36 kW

7.13 kW

COP Tj = +2°C

6.46

5.02

Cdh Tj = +2 °C

0.990

0.995

Pdh Tj = +7°C

7.37 kW

7.24 kW

COP Tj = +7°C

6.64

5.52

Cdh Tj = +7 °C

0.990

0.995

Pdh Tj = 12°C

7.37 kW

7.31 kW

COP Tj = 12°C

6.68

5.94

Cdh Tj = +12 °C

0.990

0.994

Pdh Tj = Tbiv

7.29 kW

6.87 kW

COP Tj = Tbiv

5.96

4.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.21 kW

6.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.70

3.57

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.996

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.93 kW

1.50 kW

Annual energy consumption Qhe

3199 kWh

4265 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

237 %

175 %

Prated

7.85 kW

8.07 kW

SCOP

6.12

4.58

Tbiv

-8 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.26 kW

6.78 kW

COP Tj = -7°C

5.85

3.85

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

7.32 kW

7.02 kW

COP Tj = +2°C

6.14

4.60

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

7.36 kW

7.15 kW

COP Tj = +7°C

6.43

5.12

Cdh Tj = +7 °C

0.990

1.000

Pdh Tj = 12°C

7.37 kW

7.27 kW

COP Tj = 12°C

6.71

5.70

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

7.24 kW

6.83 kW

COP Tj = Tbiv

5.80

3.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.21 kW

6.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.70

3.57

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.64 kW

1.41 kW

Annual energy consumption Qhe

2651 kWh

3641 kWh