Login

Subtype

WPF 16 basic

Certificate Holder
STIEBEL ELTRON GmbH & Co KG
Dr. Stiebel Straße 33
37603 Holzminden
Germany
Registration number
011-1W0189
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
WPF 16 basic
Driving energy
Electricity
Heat Pump Type
Brine/Water
Refrigerant
R410A
Mass of Refrigerant

2,600 kg

Certification Date
04.09.2019
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 2

Models

WPF 16 basic, all climates
Configure model
Model name
WPF 16 basic, all climates
Application
Heating (low temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Heat output

16.64 kW

El input

4.00 kW

COP

4.35

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

failed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Sound power level indoor

65 dB(A)

EN 14825

ηs

178 %

Prated

17.00 kW

SCOP

4.98

Tbiv

2 °C

TOL

-5 °C

Pdh Tj = +2°C

16.60 kW

COP Tj = +2°C

4.16

Cdh Tj = +2 °C

0.900

Pdh Tj = +7°C

16.80 kW

COP Tj = +7°C

4.47

Cdh Tj = +7 °C

0.900

Pdh Tj = 12°C

16.90 kW

COP Tj = 12°C

5.00

Cdh Tj = +12 °C

0.900

Pdh Tj = Tbiv

16.60 kW

COP Tj = Tbiv

4.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.16

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

WTOL

60 °C

Poff

0 W

PTO

78 W

PSB

3 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.40 kW

Annual energy consumption Qhe

4778 kWh

Colder Climate

EN 12102-1

Sound power level indoor

65 dB(A)

EN 14825

ηs

183 %

Prated

21.00 kW

SCOP

5.08

Tbiv

-15 °C

TOL

-20 °C

Pdh Tj = -7°C

16.80 kW

COP Tj = -7°C

4.71

Cdh Tj = -7 °C

0.900

Pdh Tj = +2°C

16.90 kW

COP Tj = +2°C

4.97

Cdh Tj = +2 °C

0.900

Pdh Tj = +7°C

17.00 kW

COP Tj = +7°C

5.20

Cdh Tj = +7 °C

0.900

Pdh Tj = 12°C

17.00 kW

COP Tj = 12°C

5.23

Cdh Tj = +12 °C

0.900

Pdh Tj = Tbiv

16.80 kW

COP Tj = Tbiv

4.60

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.16

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

WTOL

60 °C

Poff

0 W

PTO

78 W

PSB

3 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

21.00 kW

Annual energy consumption Qhe

10600 kWh

Pdh Tj = -15°C (if TOL<-20°C)

16.80

COP Tj = -15°C (if TOL<-20°C)

4.60

Cdh Tj = -15 °C

0.90

Average Climate

EN 12102-1

Sound power level indoor

65 dB(A)

EN 14825

ηs

117 %

Prated

17.00 kW

SCOP

4.80

Tbiv

-10 °C

TOL

-10 °C

Pdh Tj = -7°C

16.70 kW

COP Tj = -7°C

4.22

Cdh Tj = -7 °C

0.90

Pdh Tj = +2°C

16.80 kW

COP Tj = +2°C

4.54

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

16.90 kW

COP Tj = +7°C

4.87

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

17.00 kW

COP Tj = 12°C

5.26

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

16.60 kW

COP Tj = Tbiv

4.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.16

WTOL

60 °C

Poff

0 W

PTO

78 W

PSB

3 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

7440 kWh

WPF 16 basic, average climates
Configure model
Model name
WPF 16 basic, average climates
Application
Heating (medium temp)
Units
Indoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.64 kW

15.62 kW

El input

4.00 kW

6.34 kW

COP

4.35

2.46

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

failed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

117 %

117 %

Prated

17.00 kW

16.00 kW

SCOP

4.80

3.18

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

16.70 kW

15.70 kW

COP Tj = -7°C

4.22

2.59

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

16.80 kW

16.10 kW

COP Tj = +2°C

4.54

3.06

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

16.90 kW

16.30 kW

COP Tj = +7°C

4.87

3.43

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

17.00 kW

16.50 kW

COP Tj = 12°C

5.26

3.88

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

16.60 kW

15.60 kW

COP Tj = Tbiv

4.16

2.48

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.60 kW

15.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.16

2.48

WTOL

60 °C

60 °C

Poff

0 W

0 W

PTO

78 W

78 W

PSB

3 W

3 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

7440 kWh

10353 kWh