1,400 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.73 kW
9.69 kW
El input
2.29 kW
3.38 kW
COP
4.69
2.87
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.66 kW
2.22 kW
Cooling capacity
8.10
9.72
EER
3.04
4.38
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
8.10 kW
9.72 kW
SEER
3.72
5.46
Pdc Tj = 35°C
8.10 kW
9.72 kW
EER Tj = 35°C
3.04
4.38
Pdc Tj = 30°C
5.85 kW
6.87 kW
EER Tj = 30°C
4.13
6.10
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
3.74 kW
4.64 kW
EER Tj = 25°C
4.46
7.73
Cdc Tj = 25 °C
0.250
0.250
Pdc Tj = 20°C
3.41 kW
4.25 kW
EER Tj = 20°C
5.81
7.44
Cdc Tj = 20 °C
0.983
0.983
Poff
6 W
6 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Annual energy consumption Qce
2077 kWh
1698 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
30 dB(A)
30 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
259 %
166 %
Prated
8.33 kW
7.22 kW
SCOP
6.55
4.23
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
8.33 kW
7.22 kW
COP Tj = +2°C
3.69
2.25
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.62 kW
4.96 kW
COP Tj = +7°C
5.91
3.64
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.89 kW
4.22 kW
COP Tj = 12°C
8.00
5.44
Cdh Tj = +12 °C
0.984
0.987
Pdh Tj = Tbiv
8.33 kW
7.22 kW
COP Tj = Tbiv
3.69
2.25
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.33 kW
7.22 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.69
2.25
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
6 W
6 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1699 kWh
2280 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
30 dB(A)
30 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
119 %
Prated
6.95 kW
3.59 kW
SCOP
4.95
3.06
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.39 kW
4.45 kW
COP Tj = -7°C
3.27
1.98
Cdh Tj = -7 °C
0.900
0.996
Pdh Tj = +2°C
3.92 kW
4.11 kW
COP Tj = +2°C
4.82
2.98
Cdh Tj = +2 °C
0.900
0.993
Pdh Tj = +7°C
3.78 kW
4.51 kW
COP Tj = +7°C
6.30
4.06
Cdh Tj = +7 °C
0.984
0.991
Pdh Tj = 12°C
4.89 kW
4.26 kW
COP Tj = 12°C
8.00
5.71
Cdh Tj = +12 °C
0.984
0.987
Pdh Tj = Tbiv
6.95 kW
3.59 kW
COP Tj = Tbiv
2.70
1.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.95 kW
3.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.70
1.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
6 W
6 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2896 kWh
2427 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.73 kW
9.69 kW
El input
2.29 kW
3.38 kW
COP
4.69
2.87
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.66 kW
2.22 kW
Cooling capacity
8.10
9.72
EER
3.04
4.38
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
8.10 kW
9.72 kW
SEER
3.72
5.46
Pdc Tj = 35°C
8.10 kW
9.72 kW
EER Tj = 35°C
3.04
4.38
Pdc Tj = 30°C
5.85 kW
6.87 kW
EER Tj = 30°C
4.13
6.10
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
3.74 kW
4.64 kW
EER Tj = 25°C
4.46
7.73
Cdc Tj = 25 °C
0.250
0.250
Pdc Tj = 20°C
3.41 kW
4.25 kW
EER Tj = 20°C
5.81
7.44
Cdc Tj = 20 °C
0.983
0.983
Poff
6 W
6 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Annual energy consumption Qce
2077 kWh
1698 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
30 dB(A)
30 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
259 %
166 %
Prated
8.33 kW
7.22 kW
SCOP
6.55
4.23
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
8.33 kW
7.22 kW
COP Tj = +2°C
3.69
2.25
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.62 kW
4.96 kW
COP Tj = +7°C
5.91
3.64
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.89 kW
4.22 kW
COP Tj = 12°C
8.00
5.44
Cdh Tj = +12 °C
0.984
0.987
Pdh Tj = Tbiv
8.33 kW
7.22 kW
COP Tj = Tbiv
3.69
2.25
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.33 kW
7.22 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.69
2.25
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
6 W
6 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1699 kWh
2280 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
30 dB(A)
30 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
158 %
112 %
Prated
7.82 kW
7.19 kW
SCOP
4.03
2.86
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-15 °C
Pdh Tj = -7°C
4.82 kW
4.53 kW
COP Tj = -7°C
3.62
2.52
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.85 kW
2.88 kW
COP Tj = +2°C
4.54
3.48
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.79 kW
3.53 kW
COP Tj = +7°C
6.52
4.62
Cdh Tj = +7 °C
0.983
0.987
Pdh Tj = 12°C
4.89 kW
4.56 kW
COP Tj = 12°C
8.06
6.57
Cdh Tj = +12 °C
0.984
0.986
Pdh Tj = Tbiv
6.38 kW
5.87 kW
COP Tj = Tbiv
2.55
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.36 kW
5.87 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.05
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
6 W
6 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.46 kW
7.19 kW
Annual energy consumption Qhe
4784 kWh
6187 kWh
Pdh Tj = -15°C (if TOL<-20°C)
6.38
5.87
COP Tj = -15°C (if TOL<-20°C)
2.55
1.92
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
30 dB(A)
30 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
196 %
133 %
Prated
8.62 kW
8.17 kW
SCOP
4.98
3.41
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.63 kW
7.22 kW
COP Tj = -7°C
2.97
2.13
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.53 kW
4.53 kW
COP Tj = +2°C
5.01
3.41
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.81 kW
3.50 kW
COP Tj = +7°C
6.49
4.39
Cdh Tj = +7 °C
0.983
0.988
Pdh Tj = 12°C
4.90 kW
4.35 kW
COP Tj = 12°C
8.15
6.07
Cdh Tj = +12 °C
0.984
0.986
Pdh Tj = Tbiv
7.63 kW
7.22 kW
COP Tj = Tbiv
2.97
2.13
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.95 kW
3.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.70
1.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
6 W
6 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.68 kW
4.57 kW
Annual energy consumption Qhe
3576 kWh
4949 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.73 kW
9.69 kW
El input
2.29 kW
3.38 kW
COP
4.69
2.87
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.66 kW
2.22 kW
Cooling capacity
8.10
9.72
EER
3.04
4.38
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
8.10 kW
9.72 kW
SEER
3.72
5.46
Pdc Tj = 35°C
8.10 kW
9.72 kW
EER Tj = 35°C
3.04
4.38
Pdc Tj = 30°C
5.85 kW
6.87 kW
EER Tj = 30°C
4.13
6.10
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
3.74 kW
4.64 kW
EER Tj = 25°C
4.46
7.73
Cdc Tj = 25 °C
0.250
0.250
Pdc Tj = 20°C
3.41 kW
4.25 kW
EER Tj = 20°C
5.81
7.44
Cdc Tj = 20 °C
0.983
0.983
Poff
6 W
6 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Annual energy consumption Qce
2077 kWh
1698 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
30 dB(A)
30 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
259 %
166 %
Prated
8.33 kW
7.22 kW
SCOP
6.55
4.23
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
8.33 kW
7.22 kW
COP Tj = +2°C
3.69
2.25
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.62 kW
4.96 kW
COP Tj = +7°C
5.91
3.64
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.89 kW
4.22 kW
COP Tj = 12°C
8.00
5.44
Cdh Tj = +12 °C
0.984
0.987
Pdh Tj = Tbiv
8.33 kW
7.22 kW
COP Tj = Tbiv
3.69
2.25
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.33 kW
7.22 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.69
2.25
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
6 W
6 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1699 kWh
2280 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
30 dB(A)
30 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
158 %
112 %
Prated
7.82 kW
7.19 kW
SCOP
4.03
2.86
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-15 °C
Pdh Tj = -7°C
4.82 kW
4.53 kW
COP Tj = -7°C
3.62
2.52
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.85 kW
2.88 kW
COP Tj = +2°C
4.54
3.48
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.79 kW
3.53 kW
COP Tj = +7°C
6.52
4.62
Cdh Tj = +7 °C
0.983
0.987
Pdh Tj = 12°C
4.89 kW
4.56 kW
COP Tj = 12°C
8.06
6.57
Cdh Tj = +12 °C
0.984
0.986
Pdh Tj = Tbiv
6.38 kW
5.87 kW
COP Tj = Tbiv
2.55
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.36 kW
5.87 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.05
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
6 W
6 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.46 kW
7.19 kW
Annual energy consumption Qhe
4784 kWh
6187 kWh
Pdh Tj = -15°C (if TOL<-20°C)
6.38
5.87
COP Tj = -15°C (if TOL<-20°C)
2.55
1.92
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
30 dB(A)
30 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
196 %
133 %
Prated
8.62 kW
8.17 kW
SCOP
4.98
3.41
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.63 kW
7.22 kW
COP Tj = -7°C
2.97
2.13
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.53 kW
4.53 kW
COP Tj = +2°C
5.01
3.41
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.81 kW
3.50 kW
COP Tj = +7°C
6.49
4.39
Cdh Tj = +7 °C
0.983
0.988
Pdh Tj = 12°C
4.90 kW
4.35 kW
COP Tj = 12°C
8.15
6.07
Cdh Tj = +12 °C
0.984
0.986
Pdh Tj = Tbiv
7.63 kW
7.22 kW
COP Tj = Tbiv
2.97
2.13
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.95 kW
3.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.70
1.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
6 W
6 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.68 kW
4.57 kW
Annual energy consumption Qhe
3576 kWh
4949 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
140 %
COP
3.35
Heating up time
1:59 h:min
Standby power input
43.6 W
Reference hot water temperature
51.7 °C
Mixed water at 40°C
237 l
Colder Climate
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
110 %
COP
2.66
Heating up time
2:06 h:min
Standby power input
42.8 W
Reference hot water temperature
51.9 °C
Mixed water at 40°C
233 l