2,100 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.12 kW
14.27 kW
El input
3.03 kW
5.19 kW
COP
4.65
2.75
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
62 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
130 %
Prated
12.79 kW
12.23 kW
SCOP
4.47
3.32
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.32 kW
10.82 kW
COP Tj = -7°C
2.45
1.97
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
6.90 kW
7.36 kW
COP Tj = +2°C
4.25
3.26
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
6.64 kW
5.54 kW
COP Tj = +7°C
6.52
4.34
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
5.74 kW
6.09 kW
COP Tj = 12°C
8.88
6.09
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
11.32 kW
10.82 kW
COP Tj = Tbiv
2.45
1.97
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.27 kW
11.13 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.40
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
12 W
12 W
PTO
30 W
30 W
PSB
12 W
12 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.52 kW
1.10 kW
Annual energy consumption Qhe
5912 kWh
7599 kWh