Login

Subtype

HPA-O 6/8 CS Plus

Certificate Holder
STIEBEL ELTRON GmbH & Co KG
Dr. Stiebel Straße 33
37603 Holzminden
Germany
Registration number
011-1W0284
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
HPA-O 6/8 CS Plus
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

2,000 kg

Certification Date
03.12.2018
Testing basis
HP KEYMARK certification scheme rules rev. no. 5
Generate PDF Export model CSV
  • Number of models 11

Models

HPA-O 6 CS Plus + HSBB 200, HSBB 200 S
Configure model
Model name
HPA-O 6 CS Plus + HSBB 200, HSBB 200 S
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.86 kW

4.31 kW

El input

1.02 kW

1.58 kW

COP

4.76

2.73

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

27 dB(A)

27 dB(A)

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

125 %

Prated

6.80 kW

7.55 kW

SCOP

4.50

3.21

Tbiv

-7 °C

-5 °C

TOL

-10 °C

-7 °C

Pdh Tj = -7°C

6.02 kW

5.10 kW

COP Tj = -7°C

2.90

1.97

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

3.89 kW

4.10 kW

COP Tj = +2°C

4.35

3.25

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.50 kW

2.60 kW

COP Tj = +7°C

6.60

4.56

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.39 kW

3.30 kW

COP Tj = 12°C

6.78

5.98

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

6.02 kW

6.10 kW

COP Tj = Tbiv

2.90

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.30 kW

5.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.89

1.97

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

30 W

30 W

PSB

17 W

17 W

PCK

5 W

5 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.50 kW

7.55 kW

Annual energy consumption Qhe

3120 kWh

4865 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

113 %

COP

2.70

Heating up time

01:50 h:min

Standby power input

35.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

245 l

HPA-O 6 CS Plus, low temperature, all climates
Configure model
Model name
HPA-O 6 CS Plus, low temperature, all climates
Application
Heating (low temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Heat output

4.86 kW

El input

1.02 kW

COP

4.76

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Sound power level outdoor

57 dB(A)

EN 14825

ηs

213 %

Prated

6.30 kW

SCOP

5.41

Tbiv

2 °C

TOL

2 °C

Pdh Tj = +2°C

6.30 kW

COP Tj = +2°C

3.60

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

4.10 kW

COP Tj = +7°C

5.25

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

3.37 kW

COP Tj = 12°C

6.61

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

6.30 kW

COP Tj = Tbiv

3.60

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.60

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

WTOL

60 °C

Poff

17 W

PTO

30 W

PSB

17 W

PCK

5 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

1556 kWh

Colder Climate

EN 12102-1

Sound power level outdoor

57 dB(A)

EN 14825

ηs

151 %

Prated

5.80 kW

SCOP

3.85

Tbiv

-15 °C

TOL

-20 °C

Pdh Tj = -7°C

3.51 kW

COP Tj = -7°C

3.30

Cdh Tj = -7 °C

0.90

Pdh Tj = +2°C

2.28 kW

COP Tj = +2°C

4.55

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

2.79 kW

COP Tj = +7°C

5.81

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

3.39 kW

COP Tj = 12°C

6.71

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

5.80 kW

COP Tj = Tbiv

2.79

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

WTOL

60 °C

Poff

17 W

PTO

30 W

PSB

17 W

PCK

5 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

5.80 kW

Annual energy consumption Qhe

3713 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.80

COP Tj = -15°C (if TOL<-20°C)

2.70

Cdh Tj = -15 °C

0.90

Average Climate

EN 12102-1

Sound power level outdoor

57 dB(A)

EN 14825

ηs

177 %

Prated

6.80 kW

SCOP

4.50

Tbiv

-7 °C

TOL

-10 °C

Pdh Tj = -7°C

6.02 kW

COP Tj = -7°C

2.90

Cdh Tj = -7 °C

0.90

Pdh Tj = +2°C

3.89 kW

COP Tj = +2°C

4.35

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

3.50 kW

COP Tj = +7°C

6.60

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

3.39 kW

COP Tj = 12°C

6.78

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

6.02 kW

COP Tj = Tbiv

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

WTOL

60 °C

Poff

17 W

PTO

30 W

PSB

17 W

PCK

5 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.50 kW

Annual energy consumption Qhe

3120 kWh

HPA-O 8 CS Plus + HSBB 200, HSBB 200S
Configure model
Model name
HPA-O 8 CS Plus + HSBB 200, HSBB 200S
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.86 kW

4.31 kW

El input

1.02 kW

1.58 kW

COP

4.76

2.73

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

27 dB(A)

27 dB(A)

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

125 %

Prated

9.19 kW

7.55 kW

SCOP

4.50

3.21

Tbiv

-7 °C

-5 °C

TOL

-10 °C

-7 °C

Pdh Tj = -7°C

8.13 kW

5.10 kW

COP Tj = -7°C

2.72

1.97

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

5.22 kW

4.10 kW

COP Tj = +2°C

4.35

3.25

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.50 kW

2.60 kW

COP Tj = +7°C

6.60

4.56

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.39 kW

3.30 kW

COP Tj = 12°C

6.78

5.98

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

8.13 kW

6.10 kW

COP Tj = Tbiv

2.72

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.92 kW

5.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.97

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

30 W

30 W

PSB

17 W

17 W

PCK

5 W

5 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.27 kW

7.55 kW

Annual energy consumption Qhe

4218 kWh

4865 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

113 %

COP

2.70

Heating up time

01:50 h:min

Standby power input

35.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

245 l

HPA-O 8 CS Plus, low temperature, all climates
Configure model
Model name
HPA-O 8 CS Plus, low temperature, all climates
Application
Heating (low temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Heat output

4.86 kW

El input

1.02 kW

COP

4.76

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Sound power level outdoor

57 dB(A)

EN 14825

ηs

215 %

Prated

7.60 kW

SCOP

5.44

Tbiv

2 °C

TOL

2 °C

Pdh Tj = +2°C

7.60 kW

COP Tj = +2°C

3.44

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

4.89 kW

COP Tj = +7°C

5.15

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

3.37 kW

COP Tj = 12°C

6.61

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

7.60 kW

COP Tj = Tbiv

3.44

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.44

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

WTOL

60 °C

Poff

17 W

PTO

30 W

PSB

17 W

PCK

5 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

1867 kWh

Colder Climate

EN 12102-1

Sound power level outdoor

57 dB(A)

EN 14825

ηs

147 %

Prated

8.70 kW

SCOP

3.75

Tbiv

-15 °C

TOL

-20 °C

Pdh Tj = -7°C

5.27 kW

COP Tj = -7°C

3.17

Cdh Tj = -7 °C

0.90

Pdh Tj = +2°C

3.21 kW

COP Tj = +2°C

4.46

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

2.79 kW

COP Tj = +7°C

5.81

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

3.39 kW

COP Tj = 12°C

6.71

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

7.10 kW

COP Tj = Tbiv

2.54

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.19

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

WTOL

60 °C

Poff

17 W

PTO

30 W

PSB

17 W

PCK

5 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

8.70 kW

Annual energy consumption Qhe

5722 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.10

COP Tj = -15°C (if TOL<-20°C)

2.54

Cdh Tj = -15 °C

0.90

Average Climate

EN 12102-1

Sound power level outdoor

57 dB(A)

EN 14825

ηs

177 %

Prated

9.19 kW

SCOP

4.50

Tbiv

-7 °C

TOL

-10 °C

Pdh Tj = -7°C

8.13 kW

COP Tj = -7°C

2.72

Cdh Tj = -7 °C

0.90

Pdh Tj = +2°C

5.22 kW

COP Tj = +2°C

4.35

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

3.50 kW

COP Tj = +7°C

6.60

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

3.39 kW

COP Tj = 12°C

6.78

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

8.13 kW

COP Tj = Tbiv

2.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.92 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

WTOL

60 °C

Poff

17 W

PTO

30 W

PSB

17 W

PCK

5 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

1.27 kW

Annual energy consumption Qhe

4218 kWh

HPA-O 6 CS Plus + HSBC 200, HSBC 200S
Configure model
Model name
HPA-O 6 CS Plus + HSBC 200, HSBC 200S
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.86 kW

4.31 kW

El input

1.02 kW

1.58 kW

COP

4.76

2.73

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

27 dB(A)

27 dB(A)

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

125 %

Prated

6.80 kW

7.55 kW

SCOP

4.50

3.21

Tbiv

-7 °C

-5 °C

TOL

-10 °C

-7 °C

Pdh Tj = -7°C

6.02 kW

5.10 kW

COP Tj = -7°C

2.90

1.97

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

3.89 kW

4.10 kW

COP Tj = +2°C

4.35

3.25

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.50 kW

2.60 kW

COP Tj = +7°C

6.60

4.56

Cdh Tj = +7 °C

0.94

0.90

Pdh Tj = 12°C

3.39 kW

3.30 kW

COP Tj = 12°C

6.78

5.98

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

6.02 kW

6.10 kW

COP Tj = Tbiv

2.90

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.30 kW

5.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.97

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

30 W

30 W

PSB

17 W

17 W

PCK

5 W

5 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.50 kW

7.55 kW

Annual energy consumption Qhe

3120 kWh

4865 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

113 %

COP

2.70

Heating up time

01:50 h:min

Standby power input

35.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

245 l

HPA-O 8 CS Plus + HSBC 200, HSBC 200S
Configure model
Model name
HPA-O 8 CS Plus + HSBC 200, HSBC 200S
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.86 kW

4.31 kW

El input

1.02 kW

1.58 kW

COP

4.76

2.73

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

27 dB(A)

27 dB(A)

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

125 %

Prated

9.19 kW

7.55 kW

SCOP

4.50

3.21

Tbiv

-7 °C

-5 °C

TOL

-10 °C

-7 °C

Pdh Tj = -7°C

8.13 kW

5.10 kW

COP Tj = -7°C

2.72

1.97

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

5.22 kW

4.10 kW

COP Tj = +2°C

4.35

3.25

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.50 kW

2.60 kW

COP Tj = +7°C

6.60

4.56

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.39 kW

3.30 kW

COP Tj = 12°C

6.78

5.98

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

8.13 kW

6.10 kW

COP Tj = Tbiv

2.72

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.92 kW

5.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.97

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

30 W

30 W

PSB

17 W

17 W

PCK

5 W

5 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.27 kW

7.55 kW

Annual energy consumption Qhe

4218 kWh

4865 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

113 %

COP

2.70

Heating up time

01:50 h:min

Standby power input

35.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

245 l

HPA-O 6 CS Plus + HSBB/HSBC 180 (S) Plus (GB) "Profile M"
Configure model
Model name
HPA-O 6 CS Plus + HSBB/HSBC 180 (S) Plus (GB) "Profile M"
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.86 kW

4.31 kW

El input

1.02 kW

1.58 kW

COP

4.76

2.73

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

27 dB(A)

27 dB(A)

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

125 %

Prated

6.80 kW

7.55 kW

SCOP

4.50

3.21

Tbiv

-7 °C

-5 °C

TOL

-10 °C

-7 °C

Pdh Tj = -7°C

6.02 kW

5.10 kW

COP Tj = -7°C

2.90

1.97

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

3.89 kW

4.10 kW

COP Tj = +2°C

4.35

3.25

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.50 kW

2.60 kW

COP Tj = +7°C

6.60

4.56

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.39 kW

3.30 kW

COP Tj = 12°C

6.78

5.98

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

6.02 kW

6.10 kW

COP Tj = Tbiv

2.90

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.30 kW

5.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.89

1.97

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

30 W

30 W

PSB

17 W

17 W

PCK

5 W

5 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.50 kW

7.55 kW

Annual energy consumption Qhe

3120 kWh

4865 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

M

Efficiency ηDHW

93 %

COP

2.13

Heating up time

01:16 h:min

Standby power input

39.6 W

Reference hot water temperature

53.9 °C

Mixed water at 40°C

262 l

HPA-O 6 CS Plus + HSBB/HSBC 180 (S) Plus (GB) "Profile L"
Configure model
Model name
HPA-O 6 CS Plus + HSBB/HSBC 180 (S) Plus (GB) "Profile L"
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.86 kW

4.31 kW

El input

1.02 kW

1.58 kW

COP

4.76

2.73

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

27 dB(A)

27 dB(A)

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

125 %

Prated

6.80 kW

7.55 kW

SCOP

4.50

3.21

Tbiv

-7 °C

-5 °C

TOL

-10 °C

-7 °C

Pdh Tj = -7°C

6.02 kW

5.10 kW

COP Tj = -7°C

2.90

1.97

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

3.89 kW

4.10 kW

COP Tj = +2°C

4.35

3.25

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.50 kW

2.60 kW

COP Tj = +7°C

6.60

4.56

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.39 kW

3.30 kW

COP Tj = 12°C

6.78

5.98

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

6.02 kW

6.10 kW

COP Tj = Tbiv

2.90

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.30 kW

5.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.89

1.97

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

30 W

30 W

PSB

17 W

17 W

PCK

5 W

5 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.50 kW

7.55 kW

Annual energy consumption Qhe

3120 kWh

4865 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

102 %

COP

2.43

Heating up time

2:15 h:min

Standby power input

37.7 W

Reference hot water temperature

54.0 °C

Mixed water at 40°C

253 l

HPA-O 8 CS Plus + HSBB/HSBC 180 (S) Plus (GB) "Profile M"
Configure model
Model name
HPA-O 8 CS Plus + HSBB/HSBC 180 (S) Plus (GB) "Profile M"
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.86 kW

4.31 kW

El input

1.02 kW

1.58 kW

COP

4.76

2.73

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

27 dB(A)

27 dB(A)

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

125 %

Prated

9.19 kW

7.55 kW

SCOP

4.50

3.21

Tbiv

-7 °C

-5 °C

TOL

-10 °C

-7 °C

Pdh Tj = -7°C

8.13 kW

5.10 kW

COP Tj = -7°C

2.72

1.97

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

5.22 kW

4.10 kW

COP Tj = +2°C

4.35

3.25

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.50 kW

2.60 kW

COP Tj = +7°C

6.60

4.56

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.39 kW

3.30 kW

COP Tj = 12°C

6.78

5.98

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

8.13 kW

6.10 kW

COP Tj = Tbiv

2.72

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.92 kW

5.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.97

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

30 W

30 W

PSB

17 W

17 W

PCK

5 W

5 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.27 kW

7.55 kW

Annual energy consumption Qhe

4218 kWh

4865 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

M

Efficiency ηDHW

93 %

COP

2.12

Heating up time

1:16 h:min

Standby power input

39.6 W

Reference hot water temperature

53.9 °C

Mixed water at 40°C

262 l

HPA-O 8 CS Plus + HSBB/HSBC 180 (S) Plus (GB) "Profile L"
Configure model
Model name
HPA-O 8 CS Plus + HSBB/HSBC 180 (S) Plus (GB) "Profile L"
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.86 kW

4.31 kW

El input

1.02 kW

1.58 kW

COP

4.76

2.73

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

27 dB(A)

27 dB(A)

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

125 %

Prated

9.19 kW

7.55 kW

SCOP

4.50

3.21

Tbiv

-7 °C

-5 °C

TOL

-10 °C

-7 °C

Pdh Tj = -7°C

8.13 kW

5.10 kW

COP Tj = -7°C

2.72

1.97

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

5.22 kW

4.10 kW

COP Tj = +2°C

4.35

3.25

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.50 kW

2.60 kW

COP Tj = +7°C

6.60

4.56

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.39 kW

3.30 kW

COP Tj = 12°C

6.78

5.98

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

8.13 kW

6.10 kW

COP Tj = Tbiv

2.72

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.92 kW

5.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.97

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

30 W

30 W

PSB

17 W

17 W

PCK

5 W

5 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.27 kW

7.55 kW

Annual energy consumption Qhe

4218 kWh

4865 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

102 %

COP

2.43

Heating up time

2:15 h:min

Standby power input

37.7 W

Reference hot water temperature

54.0 °C

Mixed water at 40°C

253 l

HPA-O 8 CS Plus Int
Configure model
Model name
HPA-O 8 CS Plus Int
Application
Heating (low temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
n/a

Heating

EN 14511-2

Heat output

4.86 kW

El input

1.02 kW

COP

4.76

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Sound power level outdoor

57 dB(A)

EN 14825

ηs

215 %

Prated

7.60 kW

SCOP

5.44

Tbiv

2 °C

TOL

2 °C

Pdh Tj = +2°C

7.60 kW

COP Tj = +2°C

3.44

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

4.89 kW

COP Tj = +7°C

5.15

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

3.37 kW

COP Tj = 12°C

6.61

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

7.60 kW

COP Tj = Tbiv

3.44

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.44

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

WTOL

60 °C

Poff

17 W

PTO

30 W

PSB

17 W

PCK

5 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

1867 kWh

Colder Climate

EN 12102-1

Sound power level outdoor

57 dB(A)

EN 14825

ηs

147 %

Prated

8.70 kW

SCOP

3.75

Tbiv

-15 °C

TOL

-20 °C

Pdh Tj = -7°C

5.27 kW

COP Tj = -7°C

3.17

Cdh Tj = -7 °C

0.90

Pdh Tj = +2°C

3.21 kW

COP Tj = +2°C

4.46

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

2.79 kW

COP Tj = +7°C

5.81

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

3.39 kW

COP Tj = 12°C

6.71

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

7.10 kW

COP Tj = Tbiv

2.54

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.19

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

WTOL

60 °C

Poff

17 W

PTO

30 W

PSB

17 W

PCK

5 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

8.70 kW

Annual energy consumption Qhe

5722 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.10

COP Tj = -15°C (if TOL<-20°C)

2.54

Cdh Tj = -15 °C

0.90

Average Climate

EN 12102-1

Sound power level outdoor

57 dB(A)

EN 14825

ηs

177 %

Prated

9.19 kW

SCOP

4.50

Tbiv

-7 °C

TOL

-10 °C

Pdh Tj = -7°C

8.13 kW

COP Tj = -7°C

2.72

Cdh Tj = -7 °C

0.90

Pdh Tj = +2°C

5.22 kW

COP Tj = +2°C

4.35

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

3.50 kW

COP Tj = +7°C

6.60

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

3.39 kW

COP Tj = 12°C

6.78

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

8.13 kW

COP Tj = Tbiv

2.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.92 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

WTOL

60 °C

Poff

17 W

PTO

30 W

PSB

17 W

PCK

5 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

1.27 kW

Annual energy consumption Qhe

4218 kWh