2,900 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.62 kW
8.63 kW
El input
1.99 kW
3.51 kW
COP
4.34
2.46
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
50 dB(A)
50 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
166 %
119 %
Prated
8.68 kW
8.81 kW
SCOP
4.21
3.06
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
7.68 kW
7.79 kW
COP Tj = -7°C
2.53
1.91
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.55 kW
4.71 kW
COP Tj = +2°C
4.19
3.04
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.90 kW
2.88 kW
COP Tj = +7°C
5.73
3.87
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.28 kW
2.90 kW
COP Tj = 12°C
7.20
5.79
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.68 kW
7.79 kW
COP Tj = Tbiv
2.53
1.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.72 kW
7.25 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.43
1.48
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
7 W
7 W
PTO
35 W
35 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.00 kW
1.60 kW
Annual energy consumption Qhe
4254 kWh
5950 kWh