2,100 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.34 kW
14.13 kW
El input
3.05 kW
4.69 kW
COP
4.71
3.01
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
63 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
125 %
Prated
13.54 kW
13.34 kW
SCOP
4.50
3.21
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.98 kW
11.80 kW
COP Tj = -7°C
2.56
2.05
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
7.30 kW
7.53 kW
COP Tj = +2°C
4.54
3.08
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.19 kW
4.73 kW
COP Tj = +7°C
5.77
4.10
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
5.30 kW
5.53 kW
COP Tj = 12°C
7.86
5.93
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
11.98 kW
11.80 kW
COP Tj = Tbiv
2.56
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.06 kW
11.85 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.38
1.71
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
20 W
20 W
PSB
7 W
7 W
PCK
28 W
28 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.48 kW
1.49 kW
Annual energy consumption Qhe
6220 kWh
8584 kWh