DC Inverter Heat Pump 100

Certificate Holder
GZ Dotels Electric Appliances Co., Ltd.
No.B23, Huachuang Animation Industrial Park
Guangzhou
China
Registration number
041-K030-07
Certification Body
BRE Global Limited
Subtype title
DC Inverter Heat Pump 100
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,500 kg

Certification Date
10.01.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 11
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

KS-100W/EN8BP
Configure model
Model name
KS-100W/EN8BP
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.41 kW

9.68 kW

El input

2.18 kW

3.42 kW

COP

4.77

2.83

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

132 %

Prated

8.82 kW

7.39 kW

SCOP

4.60

3.37

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.80 kW

6.54 kW

COP Tj = -7°C

2.93

2.08

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

5.19 kW

4.41 kW

COP Tj = +2°C

4.59

3.36

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

3.38 kW

3.84 kW

COP Tj = +7°C

5.66

4.14

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

3.40 kW

3.57 kW

COP Tj = 12°C

7.38

6.15

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

7.80 kW

6.54 kW

COP Tj = Tbiv

2.93

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.65 kW

6.94 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.68

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

19 W

19 W

PSB

7 W

7 W

PCK

14 W

14 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.17 kW

0.46 kW

Annual energy consumption Qhe

3963 kWh

4533 kWh