1,030 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.04 kW
4.19 kW
El input
0.82 kW
1.50 kW
COP
4.92
2.79
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
56 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
128 %
Prated
3.87 kW
4.91 kW
SCOP
4.58
3.28
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.42 kW
4.34 kW
COP Tj = -7°C
3.01
2.15
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.37 kW
2.68 kW
COP Tj = +2°C
4.55
3.30
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
2.16 kW
1.86 kW
COP Tj = +7°C
5.46
3.79
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
2.17 kW
2.25 kW
COP Tj = 12°C
7.70
5.70
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
3.42 kW
4.34 kW
COP Tj = Tbiv
3.01
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.02 kW
4.28 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.75
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
18 W
18 W
PSB
7 W
7 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.67 kW
Annual energy consumption Qhe
1745 kWh
3090 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.10 kW
6.15 kW
El input
1.25 kW
2.19 kW
COP
4.88
2.81
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
127 %
Prated
5.81 kW
5.68 kW
SCOP
4.48
3.26
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.14 kW
5.03 kW
COP Tj = -7°C
3.05
2.11
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.49 kW
3.15 kW
COP Tj = +2°C
4.27
3.26
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
2.34 kW
2.15 kW
COP Tj = +7°C
5.60
3.87
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
2.17 kW
2.24 kW
COP Tj = 12°C
7.98
5.56
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
5.14 kW
5.03 kW
COP Tj = Tbiv
3.05
2.11
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.53 kW
4.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.68
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
66 °C
66 °C
Poff
7 W
7 W
PTO
18 W
18 W
PSB
7 W
7 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.28 kW
1.28 kW
Annual energy consumption Qhe
2677 kWh
3605 kWh