Login

Subtype

WPL 17 I(K)CS classic

Certificate Holder
STIEBEL ELTRON GmbH & Co KG
Dr. Stiebel Straße 33
37603 Holzminden
Germany
Registration number
011-1W0224
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
WPL 17 I(K)CS classic
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

2,600 kg

Certification Date
04.09.2019
Testing basis
HP KEYMARK certification scheme rules rev. no. 5
Generate PDF Export model CSV
  • Number of models 6

Models

WPL 17 IKCS classic
Configure model
Model name
WPL 17 IKCS classic
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.22 kW

3.75 kW

El input

0.92 kW

1.49 kW

COP

4.60

2.51

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

44 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

207 %

142 %

Prated

4.95 kW

4.30 kW

SCOP

5.24

3.63

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

4.95 kW

4.34 kW

COP Tj = +2°C

3.70

2.21

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

4.21 kW

3.96 kW

COP Tj = +7°C

4.90

3.21

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.31 kW

2.98 kW

COP Tj = 12°C

7.35

5.30

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

4.95 kW

4.34 kW

COP Tj = Tbiv

3.70

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.95 kW

4.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.70

2.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

56 W

56 W

PTO

21 W

21 W

PSB

56 W

56 W

PCK

26 W

26 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1262 kWh

1584 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

126 %

105 %

Prated

13.20 kW

12.70 kW

SCOP

3.23

2.69

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

7.96 kW

7.69 kW

COP Tj = -7°C

2.73

2.26

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.29 kW

4.89 kW

COP Tj = +2°C

4.24

3.49

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.19 kW

4.21 kW

COP Tj = +7°C

5.45

4.82

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.39 kW

3.23 kW

COP Tj = 12°C

8.03

6.75

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.96 kW

7.69 kW

COP Tj = Tbiv

2.73

2.26

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.13 kW

5.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.27

1.00

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

56 W

56 W

PTO

21 W

21 W

PSB

56 W

56 W

PCK

26 W

26 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

13.20 kW

12.70 kW

Annual energy consumption Qhe

10074 kWh

11651 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.21

6.18

COP Tj = -15°C (if TOL<-20°C)

2.43

1.48

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

44 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

126 %

Prated

9.20 kW

7.10 kW

SCOP

4.11

3.21

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.93 kW

6.28 kW

COP Tj = -7°C

2.61

2.13

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

5.16 kW

4.73 kW

COP Tj = +2°C

4.03

3.04

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

4.20 kW

4.20 kW

COP Tj = +7°C

5.25

4.44

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.39 kW

3.14 kW

COP Tj = 12°C

8.03

6.21

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

7.93 kW

6.28 kW

COP Tj = Tbiv

2.61

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.29 kW

2.77 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.55

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

56 W

56 W

PTO

21 W

21 W

PSB

56 W

56 W

PCK

26 W

26 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.91 kW

4.43 kW

Annual energy consumption Qhe

4621 kWh

4564 kWh

WPL 17 ICS classic
Configure model
Model name
WPL 17 ICS classic
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.27 kW

3.81 kW

El input

0.90 kW

1.48 kW

COP

4.74

2.58

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

212 %

145 %

Prated

5.02 kW

4.40 kW

SCOP

5.38

3.69

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.02 kW

4.42 kW

COP Tj = +2°C

3.83

2.27

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

4.27 kW

4.02 kW

COP Tj = +7°C

5.06

3.30

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.35 kW

3.01 kW

COP Tj = 12°C

7.50

5.35

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

5.02 kW

4.42 kW

COP Tj = Tbiv

3.83

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.02 kW

4.42 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.83

2.27

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

56 W

56 W

PTO

21 W

21 W

PSB

56 W

56 W

PCK

26 W

26 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1247 kWh

1592 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

130 %

112 %

Prated

13.40 kW

13.00 kW

SCOP

3.33

2.86

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

8.13 kW

7.84 kW

COP Tj = -7°C

2.81

2.31

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.39 kW

4.96 kW

COP Tj = +2°C

4.42

3.61

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.26 kW

4.27 kW

COP Tj = +7°C

5.65

4.98

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.43 kW

3.26 kW

COP Tj = 12°C

8.21

6.88

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.13 kW

7.84 kW

COP Tj = Tbiv

2.81

2.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.24 kW

5.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.33

2.33

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

56 W

56 W

PTO

21 W

21 W

PSB

56 W

56 W

PCK

26 W

26 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

13.40 kW

13.00 kW

Annual energy consumption Qhe

9919 kWh

11197 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.29

6.24

COP Tj = -15°C (if TOL<-20°C)

2.47

2.32

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

129 %

Prated

9.00 kW

7.20 kW

SCOP

4.24

3.30

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.98 kW

6.39 kW

COP Tj = -7°C

2.65

2.17

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

5.25 kW

4.81 kW

COP Tj = +2°C

4.19

3.14

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

4.26 kW

4.25 kW

COP Tj = +7°C

5.44

4.56

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.43 kW

3.18 kW

COP Tj = 12°C

8.21

6.33

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

7.98 kW

6.39 kW

COP Tj = Tbiv

2.65

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.35 kW

2.77 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

56 W

56 W

PTO

21 W

21 W

PSB

56 W

56 W

PCK

26 W

26 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.65 kW

4.43 kW

Annual energy consumption Qhe

4387 kWh

4506 kWh

WPL 17 ICS classic + SBB 300-1 Plus "Profile XL"
Configure model
Model name
WPL 17 ICS classic + SBB 300-1 Plus "Profile XL"
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.27 kW

3.81 kW

El input

0.90 kW

1.48 kW

COP

4.74

2.58

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

129 %

Prated

9.00 kW

7.20 kW

SCOP

4.24

3.30

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.98 kW

6.39 kW

COP Tj = -7°C

2.65

2.17

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

5.25 kW

4.81 kW

COP Tj = +2°C

4.19

3.14

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

4.26 kW

4.25 kW

COP Tj = +7°C

5.44

4.56

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.43 kW

3.18 kW

COP Tj = 12°C

8.21

6.33

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

7.98 kW

6.39 kW

COP Tj = Tbiv

2.65

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.35 kW

2.77 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

56 W

56 W

PTO

21 W

21 W

PSB

56 W

56 W

PCK

26 W

26 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.65 kW

4.43 kW

Annual energy consumption Qhe

4387 kWh

4506 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

107 %

COP

2.55

Heating up time

3:51 h:min

Standby power input

63.2 W

Reference hot water temperature

55.9 °C

Mixed water at 40°C

485 l

WPL 17 IKCS classic + SBB 300-1 Plus "Profile XL"
Configure model
Model name
WPL 17 IKCS classic + SBB 300-1 Plus "Profile XL"
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.22 kW

3.75 kW

El input

0.92 kW

1.49 kW

COP

4.60

2.51

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

44 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

126 %

Prated

9.20 kW

7.10 kW

SCOP

4.11

3.21

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.93 kW

6.28 kW

COP Tj = -7°C

2.61

2.13

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

5.16 kW

4.73 kW

COP Tj = +2°C

4.03

3.04

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

4.20 kW

4.20 kW

COP Tj = +7°C

5.25

4.44

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.39 kW

3.14 kW

COP Tj = 12°C

8.03

6.21

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

7.93 kW

6.28 kW

COP Tj = Tbiv

2.61

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.29 kW

2.77 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.55

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

56 W

56 W

PTO

21 W

21 W

PSB

56 W

56 W

PCK

26 W

26 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.91 kW

4.43 kW

Annual energy consumption Qhe

4621 kWh

4564 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

107 %

COP

2.55

Heating up time

3:51 h:min

Standby power input

63.2 W

Reference hot water temperature

55.9 °C

Mixed water at 40°C

485 l

WPL 17 ICS classic + SBB 300-1 Plus "Profile M"
Configure model
Model name
WPL 17 ICS classic + SBB 300-1 Plus "Profile M"
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.27 kW

3.81 kW

El input

0.90 kW

1.48 kW

COP

4.74

2.58

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

129 %

Prated

9.00 kW

7.20 kW

SCOP

4.24

3.30

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.98 kW

6.39 kW

COP Tj = -7°C

2.65

2.17

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

5.25 kW

4.81 kW

COP Tj = +2°C

4.19

3.14

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

4.26 kW

4.25 kW

COP Tj = +7°C

5.44

4.56

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.43 kW

3.18 kW

COP Tj = 12°C

8.21

6.33

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

7.98 kW

6.39 kW

COP Tj = Tbiv

2.65

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.35 kW

2.77 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

56 W

56 W

PTO

21 W

21 W

PSB

56 W

56 W

PCK

26 W

26 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.65 kW

4.43 kW

Annual energy consumption Qhe

4387 kWh

4506 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

M

Efficiency ηDHW

86 %

COP

1.88

Heating up time

2:56 h:min

Standby power input

69.4 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

479 l

WPL 17 IKCS classic + SBB 300-1 Plus "Profile M"
Configure model
Model name
WPL 17 IKCS classic + SBB 300-1 Plus "Profile M"
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.22 kW

3.75 kW

El input

0.92 kW

1.49 kW

COP

4.60

2.51

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

44 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

126 %

Prated

9.20 kW

7.10 kW

SCOP

4.11

3.21

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.93 kW

6.28 kW

COP Tj = -7°C

2.61

2.13

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

5.16 kW

4.73 kW

COP Tj = +2°C

4.03

3.04

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

4.20 kW

4.20 kW

COP Tj = +7°C

5.25

4.44

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.39 kW

3.14 kW

COP Tj = 12°C

8.03

6.21

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

7.93 kW

6.28 kW

COP Tj = Tbiv

2.61

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.29 kW

2.77 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.55

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

56 W

56 W

PTO

21 W

21 W

PSB

56 W

56 W

PCK

26 W

26 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.91 kW

4.43 kW

Annual energy consumption Qhe

4621 kWh

4564 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

M

Efficiency ηDHW

86 %

COP

1.88

Heating up time

2:56 h:min

Standby power input

69.4 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

479 l