1,550 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.52 kW
4.94 kW
El input
1.34 kW
1.88 kW
COP
4.12
2.63
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
123 %
Prated
7 kW
6 kW
SCOP
4.38
3.27
Tbiv
-4 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.54 kW
5.02 kW
COP Tj = -7°C
4.22
2.79
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
5.60 kW
5.19 kW
COP Tj = +2°C
4.46
3.27
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
5.64 kW
5.29 kW
COP Tj = +7°C
4.67
3.62
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
5.69 kW
5.39 kW
COP Tj = 12°C
4.91
4.02
Cdh Tj = +12 °C
0.99
1.00
Pdh Tj = Tbiv
5.57 kW
5.06 kW
COP Tj = Tbiv
4.33
2.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.52 kW
4.94 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.12
2.63
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
62 °C
62 °C
Poff
6 W
6 W
PTO
6 W
6 W
PSB
6 W
6 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.48 kW
1.06 kW
Annual energy consumption Qhe
3305 kWh
3790 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
92 %
COP
2.21
Heating up time
1:45 h:min
Standby power input
37.5 W
Reference hot water temperature
47.6 °C
Mixed water at 40°C
209 l