Login

Subtype

Inverter Heat Pump-Mono System 150

Certificate Holder
Lailey and Coates International Limited
No.128 ShaGangWest Road
528477 GuangDong
China
Registration number
041-K039-03
Certification Body
BRE Global Limited
Subtype title
Inverter Heat Pump-Mono System 150
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,100 kg

Certification Date
18.11.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 11
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

Outdoor Unit: LCM-150R; Indoor Unit: LCM-R
Configure model
Model name
Outdoor Unit: LCM-150R; Indoor Unit: LCM-R
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.35 kW

13.46 kW

El input

3.17 kW

4.55 kW

COP

4.53

2.96

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

66 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

134 %

Prated

9.25 kW

8.79 kW

SCOP

4.60

3.41

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.18 kW

7.78 kW

COP Tj = -7°C

2.75

1.99

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.30 kW

4.75 kW

COP Tj = +2°C

4.33

3.21

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.71 kW

5.46 kW

COP Tj = +7°C

6.56

4.92

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.41 kW

6.46 kW

COP Tj = 12°C

8.63

7.08

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

8.18 kW

7.78 kW

COP Tj = Tbiv

2.75

1.99

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.29 kW

6.81 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.55

1.61

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

12 W

12 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.96 kW

1.98 kW

Annual energy consumption Qhe

4154 kWh

5320 kWh