Inverter Heat Pump-Mono System 180

Certificate Holder
Lailey and Coates International Limited
No.128 ShaGangWest Road
528477 GuangDong
China
Registration number
041-K039-04
Certification Body
BRE Global Limited
Subtype title
Inverter Heat Pump-Mono System 180
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,800 kg

Certification Date
18.11.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 11
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

Outdoor Unit: LCM-180R; Indoor Unit: LCM-R
Configure model
Model name
Outdoor Unit: LCM-180R; Indoor Unit: LCM-R
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

18.06 kW

16.93 kW

El input

4.01 kW

5.73 kW

COP

4.50

2.95

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

67 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

135 %

Prated

11.75 kW

10.32 kW

SCOP

4.58

3.44

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.39 kW

9.13 kW

COP Tj = -7°C

2.84

1.83

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.01 kW

6.52 kW

COP Tj = +2°C

4.32

3.34

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.49 kW

7.47 kW

COP Tj = +7°C

6.35

4.96

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

8.53 kW

8.29 kW

COP Tj = 12°C

8.25

6.92

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

10.39 kW

9.13 kW

COP Tj = Tbiv

2.84

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.75 kW

9.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.54

1.72

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

59 °C

59 °C

Poff

12 W

12 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.00 kW

1.01 kW

Annual energy consumption Qhe

5302 kWh

6204 kWh