Login

Subtype

Inverter Heat Pump-Mono System 100

Certificate Holder
Lailey and Coates International Limited
No.128 ShaGangWest Road
528477 GuangDong
China
Registration number
041-K039-02
Certification Body
BRE Global Limited
Subtype title
Inverter Heat Pump-Mono System 100
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,000 kg

Certification Date
18.11.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 11
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

Outdoor Unit: LCM-100R; Indoor Unit: LCM-R
Configure model
Model name
Outdoor Unit: LCM-100R; Indoor Unit: LCM-R
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.76 kW

8.28 kW

El input

2.17 kW

2.98 kW

COP

4.51

2.78

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

134 %

Prated

6.54 kW

6.08 kW

SCOP

4.50

3.43

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.79 kW

5.38 kW

COP Tj = -7°C

2.67

1.89

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.14 kW

3.69 kW

COP Tj = +2°C

4.35

3.38

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.21 kW

4.13 kW

COP Tj = +7°C

6.09

4.68

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

3.78 kW

4.91 kW

COP Tj = 12°C

8.20

6.71

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

5.79 kW

5.38 kW

COP Tj = Tbiv

2.67

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.02 kW

5.28 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.44

1.70

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

59 °C

59 °C

Poff

8 W

8 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.53 kW

0.80 kW

Annual energy consumption Qhe

3002 kWh

3662 kWh