1,600 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.01 kW
7.88 kW
El input
1.67 kW
3.10 kW
COP
4.81
2.54
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
127 %
Prated
7.20 kW
6.95 kW
SCOP
4.49
3.25
Tbiv
-7 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
6.37 kW
6.15 kW
COP Tj = -7°C
3.14
2.32
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.11 kW
4.05 kW
COP Tj = +2°C
4.56
3.31
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.26 kW
4.77 kW
COP Tj = +7°C
5.83
4.20
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.86 kW
5.49 kW
COP Tj = 12°C
7.70
5.78
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.37 kW
6.15 kW
COP Tj = Tbiv
3.14
2.32
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.80 kW
5.48 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.62
1.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
50 °C
50 °C
Poff
10 W
10 W
PTO
17 W
17 W
PSB
10 W
10 W
PCK
42 W
42 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.40 kW
1.47 kW
Annual energy consumption Qhe
3308 kWh
4418 kWh