1,300 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.93 kW
4.91 kW
El input
1.01 kW
1.60 kW
COP
4.86
3.08
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
55 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
129 %
Prated
4.38 kW
5.09 kW
SCOP
4.46
3.30
Tbiv
-7 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
3.88 kW
4.50 kW
COP Tj = -7°C
2.91
2.21
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.55 kW
2.94 kW
COP Tj = +2°C
4.51
3.35
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.54 kW
2.45 kW
COP Tj = +7°C
5.99
4.19
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.00 kW
3.01 kW
COP Tj = 12°C
7.83
5.61
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
3.88 kW
4.50 kW
COP Tj = Tbiv
2.91
2.21
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.19 kW
4.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.42
1.85
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
50 °C
50 °C
Poff
10 W
10 W
PTO
13 W
16 W
PSB
10 W
10 W
PCK
42 W
42 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.20 kW
0.78 kW
Annual energy consumption Qhe
2030 kWh
3183 kWh