Login

Subtype

EVI DC Inverter Heat Pump 30

Certificate Holder
Power World Machinery Equipment Co. Ltd
No.24, The Fourth Industrial Zone, HouTing Street
Shenzhen
China
Registration number
041-K032-04 / 01
Certification Body
BRE Global Limited
Subtype title
EVI DC Inverter Heat Pump 30
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,300 kg

Certification Date
19.01.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 11
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

PW030-DKZLRS-B/S
Configure model
Model name
PW030-DKZLRS-B/S
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.93 kW

4.91 kW

El input

1.01 kW

1.60 kW

COP

4.86

3.08

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

129 %

Prated

4.38 kW

5.09 kW

SCOP

4.46

3.30

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

3.88 kW

4.50 kW

COP Tj = -7°C

2.91

2.21

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.55 kW

2.94 kW

COP Tj = +2°C

4.51

3.35

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.54 kW

2.45 kW

COP Tj = +7°C

5.99

4.19

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.00 kW

3.01 kW

COP Tj = 12°C

7.83

5.61

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.88 kW

4.50 kW

COP Tj = Tbiv

2.91

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.19 kW

4.31 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.42

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

50 °C

50 °C

Poff

10 W

10 W

PTO

13 W

16 W

PSB

10 W

10 W

PCK

42 W

42 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.20 kW

0.78 kW

Annual energy consumption Qhe

2030 kWh

3183 kWh