Login

Subtype

DC Inverter Air To Water Heat Pump 18

Certificate Holder
Foshan Ecoview Energy Saving Facility Ltd
5/F of Central Building
Daliang Shunde Dist., Foshan City
China
Registration number
041-K040-05
Certification Body
BRE Global Limited
Subtype title
DC Inverter Air To Water Heat Pump 18
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,300 kg

Certification Date
29.11.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 11
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

EV-DCM18
Configure model
Model name
EV-DCM18
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

18.05 kW

16.63 kW

El input

4.16 kW

5.88 kW

COP

4.34

2.83

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

72 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

133 %

Prated

15.02 kW

13.92 kW

SCOP

4.60

3.39

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.29 kW

12.31 kW

COP Tj = -7°C

2.89

1.95

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.87 kW

7.81 kW

COP Tj = +2°C

4.36

3.17

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

9.89 kW

9.64 kW

COP Tj = +7°C

6.16

4.96

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

11.69 kW

11.50 kW

COP Tj = 12°C

8.62

7.25

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

13.29 kW

12.31 kW

COP Tj = Tbiv

2.89

1.95

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.11 kW

12.21 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.70

1.68

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

56 °C

56 °C

Poff

14 W

14 W

PTO

14 W

14 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.92 kW

1.70 kW

Annual energy consumption Qhe

6741 kWh

8473 kWh