Login

Subtype

DC Inverter Air To Water Heat Pump 6

Certificate Holder
Foshan Ecoview Energy Saving Facility Ltd
5/F of Central Building
Daliang Shunde Dist., Foshan City
China
Registration number
041-K040-01
Certification Body
BRE Global Limited
Subtype title
DC Inverter Air To Water Heat Pump 6
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

0,900 kg

Certification Date
29.11.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 11
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

EV-DCM6
Configure model
Model name
EV-DCM6
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.07 kW

5.12 kW

El input

1.38 kW

1.95 kW

COP

4.39

2.63

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

137 %

Prated

4.89 kW

4.64 kW

SCOP

4.67

3.51

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.33 kW

4.10 kW

COP Tj = -7°C

2.79

2.03

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.71 kW

2.40 kW

COP Tj = +2°C

4.55

3.49

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.18 kW

2.91 kW

COP Tj = +7°C

6.23

4.99

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

3.62 kW

3.53 kW

COP Tj = 12°C

8.52

7.59

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

4.33 kW

4.10 kW

COP Tj = Tbiv

2.79

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.32 kW

4.14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.74

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

49 °C

49 °C

Poff

7 W

7 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.58 kW

0.49 kW

Annual energy consumption Qhe

2164 kWh

2730 kWh