0,900 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.07 kW
5.12 kW
El input
1.38 kW
1.95 kW
COP
4.39
2.63
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
137 %
Prated
4.89 kW
4.64 kW
SCOP
4.67
3.51
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.33 kW
4.10 kW
COP Tj = -7°C
2.79
2.03
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.71 kW
2.40 kW
COP Tj = +2°C
4.55
3.49
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.18 kW
2.91 kW
COP Tj = +7°C
6.23
4.99
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
3.62 kW
3.53 kW
COP Tj = 12°C
8.52
7.59
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
4.33 kW
4.10 kW
COP Tj = Tbiv
2.79
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.32 kW
4.14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.56
1.74
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
49 °C
49 °C
Poff
7 W
7 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.58 kW
0.49 kW
Annual energy consumption Qhe
2164 kWh
2730 kWh