2,800 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
15.58 kW
15.57 kW
El input
3.23 kW
4.93 kW
COP
4.82
3.16
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
63 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
133 %
Prated
13.29 kW
12.77 kW
SCOP
4.61
3.40
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.75 kW
11.29 kW
COP Tj = -7°C
3.15
2.35
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.33 kW
6.90 kW
COP Tj = +2°C
4.68
3.32
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.48 kW
8.11 kW
COP Tj = +7°C
6.07
4.63
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
9.55 kW
9.33 kW
COP Tj = 12°C
7.89
6.26
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.75 kW
11.29 kW
COP Tj = Tbiv
3.15
2.35
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.50 kW
11.66 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.88
2.08
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
57 °C
57 °C
Poff
14 W
14 W
PTO
16 W
16 W
PSB
14 W
14 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.79 kW
1.11 kW
Annual energy consumption Qhe
5953 kWh
7755 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.33 kW
16.05 kW
El input
3.40 kW
5.16 kW
COP
4.81
3.11
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
68 dB(A)
71 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
139 %
Prated
13.34 kW
14.09 kW
SCOP
4.82
3.55
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.80 kW
12.46 kW
COP Tj = -7°C
2.98
2.38
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.93 kW
7.58 kW
COP Tj = +2°C
4.63
3.34
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.58 kW
8.14 kW
COP Tj = +7°C
6.44
4.61
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
9.81 kW
9.58 kW
COP Tj = 12°C
9.02
6.81
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
11.80 kW
12.46 kW
COP Tj = Tbiv
2.98
2.38
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.93 kW
11.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.71
2.07
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
56 °C
56 °C
Poff
9 W
9 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.41 kW
2.19 kW
Annual energy consumption Qhe
5718 kWh
8187 kWh