Login

Subtype

EVI DC Inverter Air Source Heat Pumps 025

Certificate Holder
Guangzhou Sprsun New Energy Technology Dev. Co., Ltd,
No.15 Tangxi Road, Yinsha Industrial Park
511338 Guangzhou
China
Registration number
041-K036-01 / 01
Certification Body
BRE Global Limited
Subtype title
EVI DC Inverter Air Source Heat Pumps 025
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,500 kg

Certification Date
08.11.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 09
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

CGK025V3L-B
Configure model
Model name
CGK025V3L-B
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.93 kW

8.08 kW

El input

1.69 kW

2.72 kW

COP

4.71

2.97

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

137 %

Prated

7.07 kW

7.46 kW

SCOP

4.70

3.51

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.26 kW

6.60 kW

COP Tj = -7°C

3.11

2.29

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.18 kW

4.02 kW

COP Tj = +2°C

4.49

3.32

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.47 kW

4.35 kW

COP Tj = +7°C

6.10

4.50

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

5.08 kW

4.98 kW

COP Tj = 12°C

8.78

6.68

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

6.26 kW

6.60 kW

COP Tj = Tbiv

3.11

2.29

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.73 kW

6.88 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.20

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

57 °C

57 °C

Poff

9 W

9 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.35 kW

0.58 kW

Annual energy consumption Qhe

3108 kWh

4394 kWh

CGK-025V3L
Configure model
Model name
CGK-025V3L
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.87 kW

7.96 kW

El input

1.68 kW

2.77 kW

COP

4.68

2.87

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

127 %

Prated

6.81 kW

7.29 kW

SCOP

4.46

3.25

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.03 kW

6.45 kW

COP Tj = -7°C

2.95

2.18

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.08 kW

3.93 kW

COP Tj = +2°C

4.63

3.32

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.33 kW

4.13 kW

COP Tj = +7°C

5.88

4.11

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.87 kW

4.80 kW

COP Tj = 12°C

7.77

5.63

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.03 kW

6.24 kW

COP Tj = Tbiv

2.95

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.44 kW

6.45 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.62

2.18

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

56 °C

56 °C

Poff

17 W

17 W

PTO

20 W

20 W

PSB

17 W

17 W

PCK

29 W

29 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.38 kW

0.90 kW

Annual energy consumption Qhe

3159 kWh

4633 kWh