1,500 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.93 kW
8.08 kW
El input
1.69 kW
2.72 kW
COP
4.71
2.97
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
61 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
137 %
Prated
7.07 kW
7.46 kW
SCOP
4.70
3.51
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.26 kW
6.60 kW
COP Tj = -7°C
3.11
2.29
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.18 kW
4.02 kW
COP Tj = +2°C
4.49
3.32
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.47 kW
4.35 kW
COP Tj = +7°C
6.10
4.50
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
5.08 kW
4.98 kW
COP Tj = 12°C
8.78
6.68
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
6.26 kW
6.60 kW
COP Tj = Tbiv
3.11
2.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.73 kW
6.88 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.80
2.20
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
57 °C
57 °C
Poff
9 W
9 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.35 kW
0.58 kW
Annual energy consumption Qhe
3108 kWh
4394 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.87 kW
7.96 kW
El input
1.68 kW
2.77 kW
COP
4.68
2.87
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
127 %
Prated
6.81 kW
7.29 kW
SCOP
4.46
3.25
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.03 kW
6.45 kW
COP Tj = -7°C
2.95
2.18
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.08 kW
3.93 kW
COP Tj = +2°C
4.63
3.32
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.33 kW
4.13 kW
COP Tj = +7°C
5.88
4.11
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.87 kW
4.80 kW
COP Tj = 12°C
7.77
5.63
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.03 kW
6.24 kW
COP Tj = Tbiv
2.95
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.44 kW
6.45 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.62
2.18
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
56 °C
56 °C
Poff
17 W
17 W
PTO
20 W
20 W
PSB
17 W
17 W
PCK
29 W
29 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.38 kW
0.90 kW
Annual energy consumption Qhe
3159 kWh
4633 kWh