Login

Subtype

DC Inverter Heat Pump 80

Certificate Holder
GZ Dotels Electric Appliances Co., Ltd.
No.B23, Huachuang Animation Industrial Park
Guangzhou
China
Registration number
041-K030-02
Certification Body
BRE Global Limited
Subtype title
DC Inverter Heat Pump 80
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,300 kg

Certification Date
14.11.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 11
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

KS-80W/EN8BP
Configure model
Model name
KS-80W/EN8BP
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.99 kW

7.59 kW

El input

1.89 kW

3.16 kW

COP

4.24

2.40

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

125 %

Prated

7.80 kW

6.69 kW

SCOP

4.46

3.21

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.88 kW

5.92 kW

COP Tj = -7°C

2.49

1.85

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.21 kW

3.92 kW

COP Tj = +2°C

4.44

3.11

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

3.91 kW

2.99 kW

COP Tj = +7°C

6.00

4.42

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

3.27 kW

3.60 kW

COP Tj = 12°C

8.32

6.14

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

6.88 kW

5.92 kW

COP Tj = Tbiv

2.49

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.27 kW

5.37 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.08

1.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

19 W

19 W

PSB

7 W

7 W

PCK

17 W

17 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.51 kW

1.33 kW

Annual energy consumption Qhe

3607 kWh

4312 kWh