1,300 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.99 kW
7.59 kW
El input
1.89 kW
3.16 kW
COP
4.24
2.40
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
59 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
125 %
Prated
7.80 kW
6.69 kW
SCOP
4.46
3.21
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.88 kW
5.92 kW
COP Tj = -7°C
2.49
1.85
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.21 kW
3.92 kW
COP Tj = +2°C
4.44
3.11
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.91 kW
2.99 kW
COP Tj = +7°C
6.00
4.42
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
3.27 kW
3.60 kW
COP Tj = 12°C
8.32
6.14
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
6.88 kW
5.92 kW
COP Tj = Tbiv
2.49
1.85
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.27 kW
5.37 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.08
1.50
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
19 W
19 W
PSB
7 W
7 W
PCK
17 W
17 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.51 kW
1.33 kW
Annual energy consumption Qhe
3607 kWh
4312 kWh