Versati Split G2 8/10kW

Certificate Holder
Gree Electric Appliances, Inc. of Zhuhai
West Jinji Rd
519070 Qianshan, Zhuhai, Guangdong
China
Registration number
041-K004-16
Certification Body
BRE Global Limited
Subtype title
Versati Split G2 8/10kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,840 kg

Certification Date
24.10.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 09
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

GRS-CQ8.0Pd/NhH2-E+SXTVD300LC/B-E
Configure model
Model name
GRS-CQ8.0Pd/NhH2-E+SXTVD300LC/B-E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

7.20 kW

El input

1.61 kW

3.05 kW

COP

4.97

2.36

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

64 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

129 %

Prated

7.00 kW

7.00 kW

SCOP

4.60

3.30

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.20 kW

6.30 kW

COP Tj = -7°C

2.94

2.24

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.90 kW

4.10 kW

COP Tj = +2°C

4.39

3.18

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

3.00 kW

4.30 kW

COP Tj = +7°C

6.29

4.26

Cdh Tj = +7 °C

0.950

0.970

Pdh Tj = 12°C

3.60 kW

5.00 kW

COP Tj = 12°C

8.43

5.93

Cdh Tj = +12 °C

0.940

0.970

Pdh Tj = Tbiv

6.20 kW

6.30 kW

COP Tj = Tbiv

2.94

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.90 kW

6.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.69

1.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.10 kW

0.70 kW

Annual energy consumption Qhe

3149 kWh

4371 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

217 %

159 %

Prated

8.00 kW

8.00 kW

SCOP

5.50

4.05

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.20 kW

8.10 kW

COP Tj = +2°C

3.58

2.52

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.40 kW

5.30 kW

COP Tj = +7°C

4.84

3.38

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

5.10 kW

5.20 kW

COP Tj = 12°C

7.08

5.42

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

8.20 kW

8.10 kW

COP Tj = Tbiv

3.58

2.52

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.20 kW

8.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.58

2.52

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1947 kWh

2645 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

146 %

112 %

Prated

7.00 kW

7.00 kW

SCOP

3.73

2.88

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.50 kW

4.60 kW

COP Tj = -7°C

3.26

2.64

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

3.30 kW

3.30 kW

COP Tj = +2°C

4.26

3.24

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

4.30 kW

4.20 kW

COP Tj = +7°C

6.04

4.76

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

4.90 kW

4.70 kW

COP Tj = 12°C

7.26

5.86

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

5.80 kW

5.90 kW

COP Tj = Tbiv

2.63

1.77

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.50 kW

2.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.52

1.26

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.50 kW

4.10 kW

Annual energy consumption Qhe

4628 kWh

5982 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.80

5.90

COP Tj = -15°C (if TOL<-20°C)

2.63

1.77

Cdh Tj = -15 °C

 

 

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

111 %

COP

2.51

Heating up time

1:32 h:min

Standby power input

132.0 W

Reference hot water temperature

51.0 °C

Mixed water at 40°C

371 l

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

118 %

COP

2.24

Heating up time

1:27 h:min

Standby power input

86.1 W

Reference hot water temperature

51.0 °C

Mixed water at 40°C

375 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

82 %

COP

1.55

Heating up time

1:51 h:min

Standby power input

183.7 W

Reference hot water temperature

51.0 °C

Mixed water at 40°C

376 l

GRS-CQ10Pd/NhH2-E+SXTVD300LC/B-E
Configure model
Model name
GRS-CQ10Pd/NhH2-E+SXTVD300LC/B-E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.00 kW

8.55 kW

El input

2.10 kW

3.72 kW

COP

4.76

2.30

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

64 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

127 %

Prated

9.00 kW

8.00 kW

SCOP

4.60

3.25

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.70 kW

6.90 kW

COP Tj = -7°C

2.87

2.12

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.80 kW

4.20 kW

COP Tj = +2°C

4.34

3.09

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

3.10 kW

4.30 kW

COP Tj = +7°C

6.58

4.34

Cdh Tj = +7 °C

0.950

0.970

Pdh Tj = 12°C

3.70 kW

4.90 kW

COP Tj = 12°C

8.37

5.91

Cdh Tj = +12 °C

0.940

0.970

Pdh Tj = Tbiv

7.70 kW

6.90 kW

COP Tj = Tbiv

2.87

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.10 kW

6.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.90 kW

1.20 kW

Annual energy consumption Qhe

4038 kWh

5091 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

217 %

161 %

Prated

9.00 kW

9.00 kW

SCOP

5.50

4.10

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.80 kW

9.00 kW

COP Tj = +2°C

3.15

2.48

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.80 kW

5.90 kW

COP Tj = +7°C

4.86

3.56

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

5.10 kW

5.20 kW

COP Tj = 12°C

7.18

5.30

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

8.80 kW

9.00 kW

COP Tj = Tbiv

3.15

2.48

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.80 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

2.48

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2183 kWh

2927 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

149 %

110 %

Prated

8.00 kW

8.00 kW

SCOP

3.80

2.83

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.20 kW

5.30 kW

COP Tj = -7°C

3.25

2.42

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

3.20 kW

3.10 kW

COP Tj = +2°C

4.31

3.23

Cdh Tj = +2 °C

0.970

0.970

Pdh Tj = +7°C

4.30 kW

4.20 kW

COP Tj = +7°C

6.11

4.78

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

4.90 kW

4.80 kW

COP Tj = 12°C

7.30

5.91

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

6.40 kW

6.70 kW

COP Tj = Tbiv

2.69

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.60 kW

3.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.67

1.22

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.40 kW

4.70 kW

Annual energy consumption Qhe

5201 kWh

6985 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.40

6.70

COP Tj = -15°C (if TOL<-20°C)

2.69

1.83

Cdh Tj = -15 °C

 

 

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

111 %

COP

2.51

Heating up time

1:32 h:min

Standby power input

132.0 W

Reference hot water temperature

51.0 °C

Mixed water at 40°C

371 l

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

118 %

COP

2.24

Heating up time

1:27 h:min

Standby power input

86.1 W

Reference hot water temperature

51.0 °C

Mixed water at 40°C

375 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

82 %

COP

1.55

Heating up time

1:51 h:min

Standby power input

183.7 W

Reference hot water temperature

51.0 °C

Mixed water at 40°C

376 l