1,100 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.00 kW
3.60 kW
El input
0.77 kW
1.40 kW
COP
5.20
2.57
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
60 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
128 %
Prated
5.00 kW
5.00 kW
SCOP
4.65
3.28
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.60 kW
4.00 kW
COP Tj = -7°C
3.23
2.03
Cdh Tj = -7 °C
0.980
0.990
Pdh Tj = +2°C
2.90 kW
2.60 kW
COP Tj = +2°C
4.59
3.27
Cdh Tj = +2 °C
0.960
0.970
Pdh Tj = +7°C
2.60 kW
2.30 kW
COP Tj = +7°C
6.39
4.30
Cdh Tj = +7 °C
0.940
0.950
Pdh Tj = 12°C
2.80 kW
2.80 kW
COP Tj = 12°C
6.37
6.00
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
4.60 kW
4.00 kW
COP Tj = Tbiv
3.23
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.20 kW
3.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.56
1.38
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.80 kW
1.20 kW
Annual energy consumption Qhe
2216 kWh
3152 kWh
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
232 %
153 %
Prated
5.00 kW
4.00 kW
SCOP
5.88
3.90
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
4.80 kW
4.20 kW
COP Tj = +2°C
3.46
2.10
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
3.30 kW
2.60 kW
COP Tj = +7°C
5.57
3.40
Cdh Tj = +7 °C
0.960
0.970
Pdh Tj = 12°C
2.90 kW
2.70 kW
COP Tj = 12°C
7.60
5.55
Cdh Tj = +12 °C
0.930
0.950
Pdh Tj = Tbiv
4.80 kW
4.20 kW
COP Tj = Tbiv
3.46
2.10
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.80 kW
4.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.46
2.10
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1137 kWh
1365 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
145 %
95 %
Prated
4.00 kW
3.00 kW
SCOP
3.70
2.45
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
2.40 kW
1.90 kW
COP Tj = -7°C
2.68
1.72
Cdh Tj = -7 °C
0.970
0.980
Pdh Tj = +2°C
2.30 kW
1.90 kW
COP Tj = +2°C
5.34
3.41
Cdh Tj = +2 °C
0.940
0.960
Pdh Tj = +7°C
2.70 kW
2.60 kW
COP Tj = +7°C
7.04
5.29
Cdh Tj = +7 °C
0.940
0.950
Pdh Tj = 12°C
2.60 kW
2.90 kW
COP Tj = 12°C
6.90
6.71
Cdh Tj = +12 °C
0.930
0.940
Pdh Tj = Tbiv
3.10 kW
2.70 kW
COP Tj = Tbiv
2.06
1.35
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.70 kW
2.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.58
1.10
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.20 kW
0.70 kW
Annual energy consumption Qhe
2662 kWh
3015 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.10
2.70
COP Tj = -15°C (if TOL<-20°C)
2.06
1.35
Cdh Tj = -15 °C
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
107 %
COP
2.53
Heating up time
2:52 h:min
Standby power input
78.6 W
Reference hot water temperature
51.0 °C
Mixed water at 40°C
374 l
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
111 %
COP
2.62
Heating up time
1:40 h:min
Standby power input
74.8 W
Reference hot water temperature
51.0 °C
Mixed water at 40°C
375 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
79 %
COP
1.90
Heating up time
2:55 h:min
Standby power input
81.6 W
Reference hot water temperature
51.0 °C
Mixed water at 40°C
371 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.00 kW
5.40 kW
El input
1.20 kW
2.16 kW
COP
5.00
2.50
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
60 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
128 %
Prated
6.00 kW
5.00 kW
SCOP
4.60
3.28
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.30 kW
4.00 kW
COP Tj = -7°C
2.81
2.03
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.30 kW
2.60 kW
COP Tj = +2°C
4.68
3.27
Cdh Tj = +2 °C
0.960
0.970
Pdh Tj = +7°C
2.60 kW
2.30 kW
COP Tj = +7°C
6.47
4.30
Cdh Tj = +7 °C
0.940
0.950
Pdh Tj = 12°C
2.60 kW
2.80 kW
COP Tj = 12°C
5.72
6.00
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
5.30 kW
4.00 kW
COP Tj = Tbiv
2.81
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.20 kW
3.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.56
1.38
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.80 kW
1.20 kW
Annual energy consumption Qhe
2685 kWh
3152 kWh
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
232 %
159 %
Prated
5.00 kW
5.00 kW
SCOP
5.88
4.05
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.20 kW
5.10 kW
COP Tj = +2°C
3.53
2.14
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
3.30 kW
3.30 kW
COP Tj = +7°C
5.57
3.49
Cdh Tj = +7 °C
0.960
0.970
Pdh Tj = 12°C
2.90 kW
2.70 kW
COP Tj = 12°C
7.60
5.67
Cdh Tj = +12 °C
0.930
0.950
Pdh Tj = Tbiv
5.20 kW
5.10 kW
COP Tj = Tbiv
3.53
2.14
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.20 kW
5.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.53
2.14
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1136 kWh
1643 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
144 %
103 %
Prated
4.00 kW
4.00 kW
SCOP
3.68
2.65
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
2.60 kW
2.40 kW
COP Tj = -7°C
2.69
1.83
Cdh Tj = -7 °C
0.970
0.980
Pdh Tj = +2°C
2.30 kW
2.10 kW
COP Tj = +2°C
5.34
3.87
Cdh Tj = +2 °C
0.940
0.950
Pdh Tj = +7°C
2.70 kW
2.50 kW
COP Tj = +7°C
7.04
5.31
Cdh Tj = +7 °C
0.940
0.950
Pdh Tj = 12°C
2.60 kW
2.90 kW
COP Tj = 12°C
6.90
6.73
Cdh Tj = +12 °C
0.930
0.940
Pdh Tj = Tbiv
3.40 kW
3.10 kW
COP Tj = Tbiv
1.98
1.38
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.70 kW
2.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.58
1.10
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.30 kW
1.70 kW
Annual energy consumption Qhe
2674 kWh
3701 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.40
3.10
COP Tj = -15°C (if TOL<-20°C)
1.98
1.38
Cdh Tj = -15 °C
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
107 %
COP
2.53
Heating up time
2:52 h:min
Standby power input
78.6 W
Reference hot water temperature
51.0 °C
Mixed water at 40°C
374 l
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
111 %
COP
2.62
Heating up time
1:40 h:min
Standby power input
74.8 W
Reference hot water temperature
51.0 °C
Mixed water at 40°C
375 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
79 %
COP
1.90
Heating up time
2:55 h:min
Standby power input
81.6 W
Reference hot water temperature
51.0 °C
Mixed water at 40°C
371 l