1,840 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
15.5 kW
16 kW
El input
3.44 kW
5.52 kW
COP
4.51
2.9
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
64 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
131 %
Prated
13 kW
13 kW
SCOP
4.45
3.35
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.1 kW
11.6 kW
COP Tj = -7°C
2.68
1.96
Cdh Tj = -7 °C
0.99
1
Pdh Tj = +2°C
6.5 kW
7.3 kW
COP Tj = +2°C
4.35
3.33
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
4.2 kW
4.2 kW
COP Tj = +7°C
6.05
4.48
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
3.3 kW
3.1 kW
COP Tj = 12°C
7.34
5.65
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
11.1 kW
11.6 kW
COP Tj = Tbiv
2.68
1.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.7 kW
11 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.61
1.81
WTOL
60 °C
60 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.3 kW
2 kW
Annual energy consumption Qhe
6027 kWh
7958 kWh
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
236 %
171 %
Prated
13 kW
14 kW
SCOP
5.98
4.35
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
13 kW
13.7 kW
COP Tj = +2°C
3
2.29
Cdh Tj = +2 °C
0.99
1
Pdh Tj = +7°C
8.1 kW
9.3 kW
COP Tj = +7°C
5.14
3.59
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
3.7 kW
4.2 kW
COP Tj = 12°C
7.84
5.84
Cdh Tj = +12 °C
0.95
0.97
Pdh Tj = Tbiv
13 kW
13.7 kW
COP Tj = Tbiv
3
2.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13 kW
13.7 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3
2.29
WTOL
60 °C
60 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2903 kWh
4292 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
156 %
119 %
Prated
12 kW
13 kW
SCOP
3.98
3.05
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.6 kW
8.6 kW
COP Tj = -7°C
3.29
2.63
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
4.5 kW
4.7 kW
COP Tj = +2°C
4.85
3.69
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
2.8 kW
3 kW
COP Tj = +7°C
5.83
4.58
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
3.4 kW
3.2 kW
COP Tj = 12°C
7.17
5.97
Cdh Tj = +12 °C
0.95
0.95
Pdh Tj = Tbiv
10.1 kW
10.5 kW
COP Tj = Tbiv
2.57
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.8 kW
4 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.75
1.08
WTOL
60 °C
60 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.2 kW
9 kW
Annual energy consumption Qhe
7442 kWh
10476 kWh
Pdh Tj = -15°C (if TOL<-20°C)
10.1
10.5
COP Tj = -15°C (if TOL<-20°C)
2.57
1.83
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
108 %
COP
2.58
Heating up time
1:28 h:min
Standby power input
67.1 W
Reference hot water temperature
52 °C
Mixed water at 40°C
336 l
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
115 %
COP
2.73
Heating up time
1:28 h:min
Standby power input
68.2 W
Reference hot water temperature
52 °C
Mixed water at 40°C
332 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
85 %
COP
2.05
Heating up time
1:54 h:min
Standby power input
70 W
Reference hot water temperature
52 °C
Mixed water at 40°C
333 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
15.5 kW
16 kW
El input
3.44 kW
5.42 kW
COP
4.51
2.95
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
64 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
137 %
Prated
13 kW
13 kW
SCOP
4.6
3.5
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.6 kW
12 kW
COP Tj = -7°C
2.76
2.23
Cdh Tj = -7 °C
0.99
1
Pdh Tj = +2°C
6.5 kW
7.2 kW
COP Tj = +2°C
4.4
3.33
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
4.5 kW
4.5 kW
COP Tj = +7°C
6.63
4.72
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
3.3 kW
3.1 kW
COP Tj = 12°C
7.34
5.65
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
11.6 kW
12 kW
COP Tj = Tbiv
2.76
2.23
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.7 kW
11.8 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
2
WTOL
60 °C
60 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.3 kW
1.2 kW
Annual energy consumption Qhe
5886 kWh
8045 kWh
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
266 %
178 %
Prated
13 kW
14 kW
SCOP
6.73
4.53
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
13.1 kW
13.7 kW
COP Tj = +2°C
3.19
2.32
Cdh Tj = +2 °C
0.99
1
Pdh Tj = +7°C
8.4 kW
8.9 kW
COP Tj = +7°C
5.6
3.65
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
3.7 kW
4 kW
COP Tj = 12°C
9.24
6.3
Cdh Tj = +12 °C
0.94
0.96
Pdh Tj = Tbiv
13.1 kW
13.7 kW
COP Tj = Tbiv
3.19
2.32
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.1 kW
13.7 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.19
2.32
WTOL
60 °C
60 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2610 kWh
4055 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
165 %
122 %
Prated
12 kW
13 kW
SCOP
4.2
3.13
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.6 kW
8.3 kW
COP Tj = -7°C
3.33
2.62
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
4.7 kW
5.1 kW
COP Tj = +2°C
5.49
3.84
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
2.8 kW
3 kW
COP Tj = +7°C
5.83
4.58
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
3.2 kW
3.2 kW
COP Tj = 12°C
7.02
5.97
Cdh Tj = +12 °C
0.95
0.95
Pdh Tj = Tbiv
9.5 kW
11 kW
COP Tj = Tbiv
2.64
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.8 kW
4 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.83
1.08
WTOL
60 °C
60 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.2 kW
9 kW
Annual energy consumption Qhe
6908 kWh
10672 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.5
11
COP Tj = -15°C (if TOL<-20°C)
2.64
2.05
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
105 %
COP
2.52
Heating up time
1:28 h:min
Standby power input
67.1 W
Reference hot water temperature
52 °C
Mixed water at 40°C
336 l
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
108 %
COP
2.59
Heating up time
1:28 h:min
Standby power input
68.2 W
Reference hot water temperature
52 °C
Mixed water at 40°C
332 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
84 %
COP
2.04
Heating up time
1:54 h:min
Standby power input
70 W
Reference hot water temperature
52 °C
Mixed water at 40°C
333 l