Login

Subtype

Versati monobloc G3/G4 4/6k

Certificate Holder
Gree Electric Appliances, Inc. of Zhuhai
West Jinji Rd
519070 Qianshan, Zhuhai, Guangdong
China
Registration number
041-K004-12
Certification Body
BRE Global Limited
Subtype title
Versati monobloc G3/G4 4/6k
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

0,950 kg

Certification Date
24.10.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 09
Generate PDF Export model CSV Download certificate
  • Number of models 4

Models

GRS-CQ4.0Pd/NhG3-E+SXTVD300LC/B-E
Configure model
Model name
GRS-CQ4.0Pd/NhG3-E+SXTVD300LC/B-E
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

4.80 kW

El input

0.93 kW

1.48 kW

COP

5.40

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

192 %

137 %

Prated

5.00 kW

5.00 kW

SCOP

4.88

3.50

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.80 kW

4.30 kW

COP Tj = -7°C

3.43

2.47

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.10 kW

2.70 kW

COP Tj = +2°C

4.83

3.19

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

1.90 kW

1.70 kW

COP Tj = +7°C

5.95

4.89

Cdh Tj = +7 °C

0.950

0.950

Pdh Tj = 12°C

1.70 kW

1.60 kW

COP Tj = 12°C

8.49

6.61

Cdh Tj = +12 °C

0.940

0.940

Pdh Tj = Tbiv

4.80 kW

4.30 kW

COP Tj = Tbiv

3.43

2.47

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.40 kW

3.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.46

1.56

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.60 kW

1.40 kW

Annual energy consumption Qhe

2306 kWh

2882 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

239 %

170 %

Prated

5.00 kW

5.00 kW

SCOP

6.05

4.33

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.10 kW

5.20 kW

COP Tj = +2°C

3.85

2.44

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

3.40 kW

3.20 kW

COP Tj = +7°C

5.80

3.67

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

1.50 kW

1.50 kW

COP Tj = 12°C

7.20

5.79

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

5.10 kW

5.20 kW

COP Tj = Tbiv

3.85

2.44

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.10 kW

5.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.85

2.44

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.980

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1124 kWh

1604 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

168 %

112 %

Prated

5.00 kW

4.00 kW

SCOP

4.28

2.88

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

2.90 kW

2.60 kW

COP Tj = -7°C

3.43

2.05

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

1.80 kW

1.60 kW

COP Tj = +2°C

5.41

3.77

Cdh Tj = +2 °C

0.970

0.970

Pdh Tj = +7°C

1.30 kW

1.30 kW

COP Tj = +7°C

6.24

5.15

Cdh Tj = +7 °C

0.950

0.950

Pdh Tj = 12°C

1.50 kW

1.50 kW

COP Tj = 12°C

8.38

7.21

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

3.70 kW

3.50 kW

COP Tj = Tbiv

2.85

1.76

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.20 kW

2.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.65

1.20

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.80 kW

1.50 kW

Annual energy consumption Qhe

2630 kWh

3721 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.70

3.50

COP Tj = -15°C (if TOL<-20°C)

2.85

1.76

Cdh Tj = -15 °C

0.980

0.990

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

XL

Efficiency ηDHW

128 %

128 %

COP

3.06

3.06

Heating up time

4h33min h:min

4:33 h:min

Standby power input

48.3 W

48.3 W

Reference hot water temperature

49.0 °C

49.0 °C

Mixed water at 40°C

333 l

333 l

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

120 %

COP

3.34

Heating up time

4:9 h:min

Standby power input

30.0 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

326 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

90 %

COP

2.16

Heating up time

6:36 h:min

Standby power input

62.8 W

Reference hot water temperature

48.0 °C

Mixed water at 40°C

321 l

GRS-CQ6.0Pd/NhG3-E+SXTVD300LC/B-E
Configure model
Model name
GRS-CQ6.0Pd/NhG3-E+SXTVD300LC/B-E
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.00 kW

5.80 kW

El input

1.11 kW

1.84 kW

COP

5.41

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

137 %

Prated

6.00 kW

5.00 kW

SCOP

5.05

3.50

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.10 kW

4.30 kW

COP Tj = -7°C

3.22

2.47

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.40 kW

2.70 kW

COP Tj = +2°C

4.86

3.19

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.00 kW

1.70 kW

COP Tj = +7°C

7.09

4.89

Cdh Tj = +7 °C

0.950

0.950

Pdh Tj = 12°C

1.70 kW

1.60 kW

COP Tj = 12°C

8.49

6.61

Cdh Tj = +12 °C

0.940

0.940

Pdh Tj = Tbiv

5.10 kW

4.30 kW

COP Tj = Tbiv

3.22

2.47

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.40 kW

3.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.46

1.56

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.60 kW

1.40 kW

Annual energy consumption Qhe

2386 kWh

2882 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

239 %

183 %

Prated

5.00 kW

6.00 kW

SCOP

6.05

4.65

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.10 kW

6.00 kW

COP Tj = +2°C

3.85

2.50

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

3.40 kW

3.90 kW

COP Tj = +7°C

5.80

4.00

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

1.50 kW

1.70 kW

COP Tj = 12°C

7.20

6.13

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

5.10 kW

6.00 kW

COP Tj = Tbiv

3.85

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.10 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.85

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.980

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1124 kWh

1722 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

164 %

120 %

Prated

5.00 kW

5.00 kW

SCOP

4.18

3.08

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.20 kW

3.30 kW

COP Tj = -7°C

3.47

2.55

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

1.90 kW

1.80 kW

COP Tj = +2°C

5.18

3.67

Cdh Tj = +2 °C

0.970

0.970

Pdh Tj = +7°C

1.30 kW

1.30 kW

COP Tj = +7°C

6.24

5.15

Cdh Tj = +7 °C

0.950

0.950

Pdh Tj = 12°C

1.50 kW

1.50 kW

COP Tj = 12°C

8.38

7.21

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

3.90 kW

4.00 kW

COP Tj = Tbiv

2.77

1.91

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.20 kW

2.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.65

1.20

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.80 kW

2.50 kW

Annual energy consumption Qhe

2825 kWh

3976 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.90

4.00

COP Tj = -15°C (if TOL<-20°C)

2.77

1.91

Cdh Tj = -15 °C

0.980

0.990

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

XL

Efficiency ηDHW

128 %

128 %

COP

3.06

3.06

Heating up time

4h33min h:min

4:33 h:min

Standby power input

48.3 W

48.3 W

Reference hot water temperature

49.0 °C

49.0 °C

Mixed water at 40°C

333 l

333 l

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

120 %

COP

3.34

Heating up time

4:9 h:min

Standby power input

30.0 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

326 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

90 %

COP

2.16

Heating up time

6:36 h:min

Standby power input

62.8 W

Reference hot water temperature

48.0 °C

Mixed water at 40°C

321 l

GRS-CQ4.0Pd/NhG4-E+SXTVD300LC/B-E
Configure model
Model name
GRS-CQ4.0Pd/NhG4-E+SXTVD300LC/B-E
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

4.80 kW

El input

0.93 kW

1.48 kW

COP

5.40

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

192 %

137 %

Prated

5.00 kW

5.00 kW

SCOP

4.88

3.50

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.80 kW

4.30 kW

COP Tj = -7°C

3.43

2.47

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.10 kW

2.70 kW

COP Tj = +2°C

4.83

3.19

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

1.90 kW

1.70 kW

COP Tj = +7°C

5.95

4.89

Cdh Tj = +7 °C

0.950

0.950

Pdh Tj = 12°C

1.70 kW

1.60 kW

COP Tj = 12°C

8.49

6.61

Cdh Tj = +12 °C

0.940

0.940

Pdh Tj = Tbiv

4.80 kW

4.30 kW

COP Tj = Tbiv

3.43

2.47

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.40 kW

3.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.46

1.56

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.60 kW

1.40 kW

Annual energy consumption Qhe

2306 kWh

2882 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

239 %

170 %

Prated

5.00 kW

5.00 kW

SCOP

6.05

4.33

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.10 kW

5.20 kW

COP Tj = +2°C

3.85

2.44

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

3.40 kW

3.20 kW

COP Tj = +7°C

5.80

3.67

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

1.50 kW

1.50 kW

COP Tj = 12°C

7.20

5.79

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

5.10 kW

5.20 kW

COP Tj = Tbiv

3.85

2.44

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.10 kW

5.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.85

2.44

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.980

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1124 kWh

1604 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

168 %

112 %

Prated

5.00 kW

4.00 kW

SCOP

4.28

2.88

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

2.90 kW

2.60 kW

COP Tj = -7°C

3.43

2.05

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

1.80 kW

1.60 kW

COP Tj = +2°C

5.41

3.77

Cdh Tj = +2 °C

0.970

0.970

Pdh Tj = +7°C

1.30 kW

1.30 kW

COP Tj = +7°C

6.24

5.15

Cdh Tj = +7 °C

0.950

0.950

Pdh Tj = 12°C

1.50 kW

1.50 kW

COP Tj = 12°C

8.38

7.21

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

3.70 kW

3.50 kW

COP Tj = Tbiv

2.85

1.76

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.20 kW

2.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.65

1.20

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.80 kW

1.50 kW

Annual energy consumption Qhe

2630 kWh

3721 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.70

3.50

COP Tj = -15°C (if TOL<-20°C)

2.85

1.76

Cdh Tj = -15 °C

0.980

0.990

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

XL

Efficiency ηDHW

128 %

128 %

COP

3.06

3.06

Heating up time

4h33min h:min

4:33 h:min

Standby power input

48.3 W

48.3 W

Reference hot water temperature

49.0 °C

49.0 °C

Mixed water at 40°C

333 l

333 l

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

120 %

COP

3.34

Heating up time

4:9 h:min

Standby power input

30.0 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

326 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

90 %

COP

2.16

Heating up time

6:36 h:min

Standby power input

62.8 W

Reference hot water temperature

48.0 °C

Mixed water at 40°C

321 l

GRS-CQ6.0Pd/NhG4-E+SXTVD300LC/B-E
Configure model
Model name
GRS-CQ6.0Pd/NhG4-E+SXTVD300LC/B-E
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.00 kW

5.80 kW

El input

1.11 kW

1.84 kW

COP

5.41

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

137 %

Prated

6.00 kW

5.00 kW

SCOP

5.05

3.50

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.10 kW

4.30 kW

COP Tj = -7°C

3.22

2.47

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.40 kW

2.70 kW

COP Tj = +2°C

4.86

3.19

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.00 kW

1.70 kW

COP Tj = +7°C

7.09

4.89

Cdh Tj = +7 °C

0.950

0.950

Pdh Tj = 12°C

1.70 kW

1.60 kW

COP Tj = 12°C

8.49

6.61

Cdh Tj = +12 °C

0.940

0.940

Pdh Tj = Tbiv

5.10 kW

4.30 kW

COP Tj = Tbiv

3.22

2.47

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.40 kW

3.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.46

1.56

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.60 kW

1.40 kW

Annual energy consumption Qhe

2386 kWh

2882 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

239 %

183 %

Prated

5.00 kW

6.00 kW

SCOP

6.05

4.65

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.10 kW

6.00 kW

COP Tj = +2°C

3.85

2.50

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

3.40 kW

3.90 kW

COP Tj = +7°C

5.80

4.00

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

1.50 kW

1.70 kW

COP Tj = 12°C

7.20

6.13

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

5.10 kW

6.00 kW

COP Tj = Tbiv

3.85

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.10 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.85

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.980

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1124 kWh

1722 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

164 %

120 %

Prated

5.00 kW

5.00 kW

SCOP

4.18

3.08

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.20 kW

3.30 kW

COP Tj = -7°C

3.47

2.55

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

1.90 kW

1.80 kW

COP Tj = +2°C

5.18

3.67

Cdh Tj = +2 °C

0.970

0.970

Pdh Tj = +7°C

1.30 kW

1.30 kW

COP Tj = +7°C

6.24

5.15

Cdh Tj = +7 °C

0.950

0.950

Pdh Tj = 12°C

1.50 kW

1.50 kW

COP Tj = 12°C

8.38

7.21

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

3.90 kW

4.00 kW

COP Tj = Tbiv

2.77

1.91

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.20 kW

2.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.65

1.20

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.80 kW

2.50 kW

Annual energy consumption Qhe

2825 kWh

3976 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.90

4.00

COP Tj = -15°C (if TOL<-20°C)

2.77

1.91

Cdh Tj = -15 °C

0.980

0.990

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

XL

Efficiency ηDHW

128 %

128 %

COP

3.06

3.06

Heating up time

4h33min h:min

4:33 h:min

Standby power input

48.3 W

48.3 W

Reference hot water temperature

49.0 °C

49.0 °C

Mixed water at 40°C

333 l

333 l

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

120 %

COP

3.34

Heating up time

4:9 h:min

Standby power input

30.0 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

326 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

90 %

COP

2.16

Heating up time

6:36 h:min

Standby power input

62.8 W

Reference hot water temperature

48.0 °C

Mixed water at 40°C

321 l