Login

Subtype

Versati monobloc G3/G4 12/14/16k

Certificate Holder
Gree Electric Appliances, Inc. of Zhuhai
West Jinji Rd
519070 Qianshan, Zhuhai, Guangdong
China
Registration number
041-K004-14
Certification Body
BRE Global Limited
Subtype title
Versati monobloc G3/G4 12/14/16k
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,200 kg

Certification Date
24.10.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 09
Generate PDF Export model CSV Download certificate
  • Number of models 12

Models

GRS-CQ12Pd/NhG3-E+SXTVD300LC/B-E
Configure model
Model name
GRS-CQ12Pd/NhG3-E+SXTVD300LC/B-E
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.43 kW

3.93 kW

COP

4.94

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

149 %

Prated

12.00 kW

12.00 kW

SCOP

4.78

3.80

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.70 kW

10.30 kW

COP Tj = -7°C

2.98

2.11

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

6.10 kW

6.80 kW

COP Tj = +2°C

4.38

3.81

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

4.10 kW

4.30 kW

COP Tj = +7°C

7.03

5.01

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

3.40 kW

3.60 kW

COP Tj = 12°C

9.49

7.32

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

10.70 kW

10.30 kW

COP Tj = Tbiv

2.98

2.11

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.20 kW

9.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.62

1.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.80 kW

2.20 kW

Annual energy consumption Qhe

5194 kWh

6388 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

273 %

180 %

Prated

12.00 kW

12.00 kW

SCOP

6.90

4.58

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.60 kW

12.20 kW

COP Tj = +2°C

3.65

2.27

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

7.30 kW

8.10 kW

COP Tj = +7°C

5.74

3.74

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

3.30 kW

3.50 kW

COP Tj = 12°C

9.38

6.29

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

11.60 kW

12.20 kW

COP Tj = Tbiv

3.65

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.60 kW

12.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.65

2.27

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2236 kWh

3558 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

181 %

129 %

Prated

11.00 kW

12.00 kW

SCOP

4.60

3.30

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.90 kW

7.80 kW

COP Tj = -7°C

3.88

2.77

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.10 kW

4.40 kW

COP Tj = +2°C

5.71

3.95

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

2.70 kW

2.80 kW

COP Tj = +7°C

7.20

5.55

Cdh Tj = +7 °C

0.930

0.950

Pdh Tj = 12°C

3.20 kW

3.30 kW

COP Tj = 12°C

8.77

7.45

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

9.20 kW

9.90 kW

COP Tj = Tbiv

2.74

1.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.90 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.89

1.18

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.10 kW

5.00 kW

Annual energy consumption Qhe

6044 kWh

9034 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.20

9.90

COP Tj = -15°C (if TOL<-20°C)

2.74

1.96

Cdh Tj = -15 °C

0.990

0.990

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

110 %

COP

2.63

Heating up time

1:38 h:min

Standby power input

60.2 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

325 l

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

113 %

COP

2.71

Heating up time

1:40 h:min

Standby power input

57.8 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

323 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

87 %

COP

2.08

Heating up time

2:15 h:min

Standby power input

72.9 W

Reference hot water temperature

48.0 °C

Mixed water at 40°C

330 l

GRS-CQ12Pd/NhG3-M+SXTVD300LC/B-M
Configure model
Model name
GRS-CQ12Pd/NhG3-M+SXTVD300LC/B-M
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.49 kW

4.12 kW

COP

4.82

2.91

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

150 %

Prated

12.00 kW

12.00 kW

SCOP

4.58

3.83

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.80 kW

10.50 kW

COP Tj = -7°C

3.01

2.02

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

6.70 kW

6.60 kW

COP Tj = +2°C

4.50

3.76

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

4.50 kW

4.50 kW

COP Tj = +7°C

5.82

5.51

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

3.30 kW

3.50 kW

COP Tj = 12°C

7.45

7.06

Cdh Tj = +12 °C

0.940

0.960

Pdh Tj = Tbiv

10.80 kW

10.50 kW

COP Tj = Tbiv

3.01

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.90 kW

11.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

2.02

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.10 kW

0.50 kW

Annual energy consumption Qhe

5517 kWh

6391 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

244 %

169 %

Prated

12.00 kW

12.00 kW

SCOP

6.18

4.30

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.70 kW

12.30 kW

COP Tj = +2°C

3.43

2.51

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

7.50 kW

7.90 kW

COP Tj = +7°C

5.41

3.50

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

3.50 kW

3.60 kW

COP Tj = 12°C

7.85

5.80

Cdh Tj = +12 °C

0.940

0.960

Pdh Tj = Tbiv

11.70 kW

12.30 kW

COP Tj = Tbiv

3.43

2.51

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.70 kW

12.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.43

2.51

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2531 kWh

3822 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

159 %

117 %

Prated

11.00 kW

12.00 kW

SCOP

4.05

3.00

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.00 kW

7.80 kW

COP Tj = -7°C

3.40

2.55

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.20 kW

4.40 kW

COP Tj = +2°C

5.04

3.71

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

3.00 kW

2.90 kW

COP Tj = +7°C

6.04

4.61

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.30 kW

3.30 kW

COP Tj = 12°C

7.23

5.24

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

9.00 kW

9.60 kW

COP Tj = Tbiv

2.42

1.79

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

6.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.79

1.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.40 kW

5.30 kW

Annual energy consumption Qhe

6685 kWh

9548 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.00

9.60

COP Tj = -15°C (if TOL<-20°C)

2.42

1.79

Cdh Tj = -15 °C

0.990

0.990

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

110 %

COP

2.63

Heating up time

1:38 h:min

Standby power input

60.2 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

325 l

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

113 %

COP

2.71

Heating up time

1:40 h:min

Standby power input

57.8 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

323 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

87 %

COP

2.08

Heating up time

2:15 h:min

Standby power input

72.9 W

Reference hot water temperature

48.0 °C

Mixed water at 40°C

330 l

GRS-CQ14Pd/NhG3-E+SXTVD300LC/B-E
Configure model
Model name
GRS-CQ14Pd/NhG3-E+SXTVD300LC/B-E
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.20 kW

13.80 kW

El input

2.99 kW

4.67 kW

COP

4.75

2.95

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

147 %

Prated

13.00 kW

13.00 kW

SCOP

4.70

3.75

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

11.80 kW

COP Tj = -7°C

2.71

2.10

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

7.10 kW

6.80 kW

COP Tj = +2°C

4.39

3.81

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

4.40 kW

4.80 kW

COP Tj = +7°C

6.89

4.77

Cdh Tj = +7 °C

0.960

0.980

Pdh Tj = 12°C

3.50 kW

3.60 kW

COP Tj = 12°C

10.30

7.36

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

11.50 kW

11.80 kW

COP Tj = Tbiv

2.71

2.10

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.50 kW

9.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.38

1.74

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.50 kW

3.40 kW

Annual energy consumption Qhe

5682 kWh

7352 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

268 %

186 %

Prated

14.00 kW

14.00 kW

SCOP

6.78

4.73

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14.00 kW

14.20 kW

COP Tj = +2°C

3.38

2.30

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

8.40 kW

8.40 kW

COP Tj = +7°C

5.57

3.73

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

3.80 kW

4.20 kW

COP Tj = 12°C

9.32

6.75

Cdh Tj = +12 °C

0.940

0.960

Pdh Tj = Tbiv

14.00 kW

14.20 kW

COP Tj = Tbiv

3.38

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.00 kW

14.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.38

2.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2755 kWh

4008 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

184 %

132 %

Prated

12.00 kW

13.00 kW

SCOP

4.68

3.38

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.90 kW

7.80 kW

COP Tj = -7°C

3.88

2.77

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.50 kW

5.20 kW

COP Tj = +2°C

5.93

4.23

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

2.70 kW

2.90 kW

COP Tj = +7°C

7.20

5.24

Cdh Tj = +7 °C

0.930

0.950

Pdh Tj = 12°C

3.20 kW

3.30 kW

COP Tj = 12°C

8.98

7.55

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

9.70 kW

10.70 kW

COP Tj = Tbiv

2.72

1.99

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.90 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.89

1.18

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.10 kW

6.00 kW

Annual energy consumption Qhe

6257 kWh

9572 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.70

10.70

COP Tj = -15°C (if TOL<-20°C)

2.72

1.99

Cdh Tj = -15 °C

0.990

0.990

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

110 %

COP

2.63

Heating up time

1:38 h:min

Standby power input

60.2 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

325 l

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

113 %

COP

2.71

Heating up time

1:40 h:min

Standby power input

57.8 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

323 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

87 %

COP

2.08

Heating up time

2:15 h:min

Standby power input

72.9 W

Reference hot water temperature

48.0 °C

Mixed water at 40°C

330 l

GRS-CQ14Pd/NhG3-M+SXTVD300LC/B-M
Configure model
Model name
GRS-CQ14Pd/NhG3-M+SXTVD300LC/B-M
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.20 kW

13.80 kW

El input

3.09 kW

4.84 kW

COP

4.60

2.85

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

150 %

Prated

13.00 kW

13.00 kW

SCOP

4.55

3.83

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.60 kW

11.80 kW

COP Tj = -7°C

2.89

2.21

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

6.70 kW

6.90 kW

COP Tj = +2°C

4.50

3.65

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

4.50 kW

4.50 kW

COP Tj = +7°C

5.82

5.51

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

3.40 kW

3.50 kW

COP Tj = 12°C

7.53

7.06

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

11.60 kW

11.80 kW

COP Tj = Tbiv

2.89

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.10 kW

11.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.28

2.02

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.90 kW

1.40 kW

Annual energy consumption Qhe

5927 kWh

7176 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

240 %

159 %

Prated

14.00 kW

15.00 kW

SCOP

6.08

4.05

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13.70 kW

14.60 kW

COP Tj = +2°C

2.90

2.31

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

8.50 kW

8.80 kW

COP Tj = +7°C

5.36

3.29

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

3.70 kW

3.90 kW

COP Tj = 12°C

7.86

5.47

Cdh Tj = +12 °C

0.950

0.970

Pdh Tj = Tbiv

13.70 kW

14.60 kW

COP Tj = Tbiv

2.90

2.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.70 kW

14.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.31

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2995 kWh

4801 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

158 %

118 %

Prated

12.00 kW

13.00 kW

SCOP

4.03

3.03

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.00 kW

7.80 kW

COP Tj = -7°C

3.40

2.55

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.20 kW

4.40 kW

COP Tj = +2°C

5.04

3.71

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

3.00 kW

2.90 kW

COP Tj = +7°C

6.06

4.61

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.20 kW

3.30 kW

COP Tj = 12°C

6.17

5.03

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

9.70 kW

10.40 kW

COP Tj = Tbiv

2.38

1.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

6.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.79

1.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.40 kW

6.30 kW

Annual energy consumption Qhe

7293 kWh

10373 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.70

10.40

COP Tj = -15°C (if TOL<-20°C)

2.38

1.82

Cdh Tj = -15 °C

0.990

0.990

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

110 %

COP

2.63

Heating up time

1:38 h:min

Standby power input

60.2 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

325 l

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

113 %

COP

2.71

Heating up time

1:40 h:min

Standby power input

57.8 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

323 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

87 %

COP

2.08

Heating up time

2:15 h:min

Standby power input

72.9 W

Reference hot water temperature

48.0 °C

Mixed water at 40°C

330 l

GRS-CQ16Pd/NhG3-E+SXTVD300LC/B-E
Configure model
Model name
GRS-CQ16Pd/NhG3-E+SXTVD300LC/B-E
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.70 kW

15.40 kW

El input

3.45 kW

5.31 kW

COP

4.55

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

146 %

Prated

14.00 kW

14.00 kW

SCOP

4.68

3.73

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.20 kW

12.30 kW

COP Tj = -7°C

2.68

2.18

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

7.10 kW

6.80 kW

COP Tj = +2°C

4.39

3.81

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

4.70 kW

4.80 kW

COP Tj = +7°C

6.86

4.77

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

3.50 kW

3.60 kW

COP Tj = 12°C

10.30

7.36

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

12.20 kW

12.30 kW

COP Tj = Tbiv

2.68

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.20 kW

8.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.38

1.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.80 kW

5.50 kW

Annual energy consumption Qhe

6072 kWh

7675 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

267 %

186 %

Prated

14.00 kW

14.00 kW

SCOP

6.75

4.73

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14.20 kW

14.20 kW

COP Tj = +2°C

3.35

2.30

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

8.40 kW

8.40 kW

COP Tj = +7°C

5.57

3.73

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

3.80 kW

4.20 kW

COP Tj = 12°C

9.32

6.75

Cdh Tj = +12 °C

0.940

0.960

Pdh Tj = Tbiv

14.20 kW

14.20 kW

COP Tj = Tbiv

3.35

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.20 kW

14.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.35

2.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2800 kWh

4008 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

184 %

132 %

Prated

12.00 kW

13.00 kW

SCOP

4.68

3.38

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.90 kW

7.80 kW

COP Tj = -7°C

3.88

2.77

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.50 kW

5.20 kW

COP Tj = +2°C

5.93

4.23

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

2.70 kW

2.90 kW

COP Tj = +7°C

7.20

5.24

Cdh Tj = +7 °C

0.930

0.950

Pdh Tj = 12°C

3.20 kW

3.30 kW

COP Tj = 12°C

8.98

7.55

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

9.70 kW

10.70 kW

COP Tj = Tbiv

2.71

1.99

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.90 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.89

1.18

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.10 kW

6.00 kW

Annual energy consumption Qhe

6257 kWh

9572 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.70

10.70

COP Tj = -15°C (if TOL<-20°C)

2.71

1.99

Cdh Tj = -15 °C

0.990

0.990

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

110 %

COP

2.63

Heating up time

1:38 h:min

Standby power input

60.2 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

325 l

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

113 %

COP

2.71

Heating up time

1:40 h:min

Standby power input

57.8 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

323 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

87 %

COP

2.08

Heating up time

2:15 h:min

Standby power input

72.9 W

Reference hot water temperature

48.0 °C

Mixed water at 40°C

330 l

GRS-CQ16Pd/NhG3-M+SXTVD300LC/B-M
Configure model
Model name
GRS-CQ16Pd/NhG3-M+SXTVD300LC/B-M
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.70 kW

15.40 kW

El input

3.57 kW

5.60 kW

COP

4.40

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

150 %

Prated

13.00 kW

14.00 kW

SCOP

4.55

3.83

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.60 kW

12.10 kW

COP Tj = -7°C

2.89

2.16

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

6.70 kW

6.90 kW

COP Tj = +2°C

4.50

3.65

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

4.50 kW

4.50 kW

COP Tj = +7°C

5.82

5.51

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

3.40 kW

3.50 kW

COP Tj = 12°C

7.53

7.06

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

11.60 kW

12.10 kW

COP Tj = Tbiv

2.89

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.10 kW

11.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.29

2.02

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.90 kW

2.50 kW

Annual energy consumption Qhe

5927 kWh

7404 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

241 %

159 %

Prated

14.00 kW

15.00 kW

SCOP

6.10

4.05

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13.70 kW

14.60 kW

COP Tj = +2°C

2.90

2.31

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

8.50 kW

8.80 kW

COP Tj = +7°C

5.36

3.29

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

3.70 kW

3.90 kW

COP Tj = 12°C

7.86

5.47

Cdh Tj = +12 °C

0.950

0.970

Pdh Tj = Tbiv

13.70 kW

14.60 kW

COP Tj = Tbiv

2.90

2.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.70 kW

14.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.31

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2995 kWh

4801 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

158 %

118 %

Prated

12.00 kW

13.00 kW

SCOP

4.03

3.03

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.00 kW

7.80 kW

COP Tj = -7°C

3.40

2.55

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.20 kW

4.40 kW

COP Tj = +2°C

5.04

3.71

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

3.00 kW

2.90 kW

COP Tj = +7°C

6.06

4.61

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.20 kW

3.30 kW

COP Tj = 12°C

6.17

5.02

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

9.70 kW

10.40 kW

COP Tj = Tbiv

2.38

1.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

6.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.79

1.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.40 kW

6.30 kW

Annual energy consumption Qhe

7293 kWh

10373 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.70

10.40

COP Tj = -15°C (if TOL<-20°C)

2.38

1.82

Cdh Tj = -15 °C

0.990

0.990

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

110 %

COP

2.63

Heating up time

1:38 h:min

Standby power input

60.2 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

325 l

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

113 %

COP

2.71

Heating up time

1:40 h:min

Standby power input

57.8 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

323 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

87 %

COP

2.08

Heating up time

2:15 h:min

Standby power input

72.9 W

Reference hot water temperature

48.0 °C

Mixed water at 40°C

330 l

GRS-CQ12Pd/NhG4-E+SXTVD300LC/B-E
Configure model
Model name
GRS-CQ12Pd/NhG4-E+SXTVD300LC/B-E
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.43 kW

3.93 kW

COP

4.94

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

149 %

Prated

12.00 kW

12.00 kW

SCOP

4.78

3.80

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.70 kW

10.30 kW

COP Tj = -7°C

2.98

2.11

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

6.10 kW

6.80 kW

COP Tj = +2°C

4.38

3.81

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

4.10 kW

4.30 kW

COP Tj = +7°C

7.03

5.01

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

3.40 kW

3.60 kW

COP Tj = 12°C

9.49

7.32

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

10.70 kW

10.30 kW

COP Tj = Tbiv

2.98

2.11

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.20 kW

9.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.62

1.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.80 kW

2.20 kW

Annual energy consumption Qhe

5194 kWh

6388 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

273 %

180 %

Prated

12.00 kW

12.00 kW

SCOP

6.90

4.58

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.60 kW

12.20 kW

COP Tj = +2°C

3.65

2.27

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

7.30 kW

8.10 kW

COP Tj = +7°C

5.74

3.74

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

3.30 kW

3.50 kW

COP Tj = 12°C

9.38

6.29

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

11.60 kW

12.20 kW

COP Tj = Tbiv

3.65

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.60 kW

12.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.65

2.27

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2236 kWh

3558 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

181 %

129 %

Prated

11.00 kW

12.00 kW

SCOP

4.60

3.30

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.90 kW

7.80 kW

COP Tj = -7°C

3.88

2.77

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.10 kW

4.40 kW

COP Tj = +2°C

5.71

3.95

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

2.70 kW

2.80 kW

COP Tj = +7°C

7.20

5.55

Cdh Tj = +7 °C

0.930

0.950

Pdh Tj = 12°C

3.20 kW

3.30 kW

COP Tj = 12°C

8.77

7.45

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

9.20 kW

9.90 kW

COP Tj = Tbiv

2.74

1.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.90 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.89

1.18

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.10 kW

5.00 kW

Annual energy consumption Qhe

6044 kWh

9034 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.20

9.90

COP Tj = -15°C (if TOL<-20°C)

2.74

1.96

Cdh Tj = -15 °C

0.990

0.990

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

110 %

COP

2.63

Heating up time

1:38 h:min

Standby power input

60.2 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

325 l

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

113 %

COP

2.71

Heating up time

1:40 h:min

Standby power input

57.8 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

323 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

87 %

COP

2.08

Heating up time

2:15 h:min

Standby power input

72.9 W

Reference hot water temperature

48.0 °C

Mixed water at 40°C

330 l

GRS-CQ12Pd/NhG4-M+SXTVD300LC/B-M
Configure model
Model name
GRS-CQ12Pd/NhG4-M+SXTVD300LC/B-M
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.49 kW

4.12 kW

COP

4.82

2.91

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

150 %

Prated

12.00 kW

12.00 kW

SCOP

4.58

3.83

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.80 kW

10.50 kW

COP Tj = -7°C

3.01

2.02

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

6.70 kW

6.60 kW

COP Tj = +2°C

4.50

3.76

Cdh Tj = +2 °C

0.970

0.990

Pdh Tj = +7°C

4.50 kW

4.50 kW

COP Tj = +7°C

5.82

5.51

Cdh Tj = +7 °C

0.960

0.980

Pdh Tj = 12°C

3.30 kW

3.50 kW

COP Tj = 12°C

7.45

7.06

Cdh Tj = +12 °C

0.940

0.960

Pdh Tj = Tbiv

10.80 kW

10.50 kW

COP Tj = Tbiv

3.01

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.90 kW

11.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

2.02

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.10 kW

0.50 kW

Annual energy consumption Qhe

5517 kWh

6391 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

244 %

169 %

Prated

12.00 kW

12.00 kW

SCOP

6.18

4.30

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.70 kW

12.30 kW

COP Tj = +2°C

3.43

2.51

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

7.50 kW

7.90 kW

COP Tj = +7°C

5.41

3.50

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

3.50 kW

3.60 kW

COP Tj = 12°C

7.85

5.80

Cdh Tj = +12 °C

0.940

0.960

Pdh Tj = Tbiv

11.70 kW

12.30 kW

COP Tj = Tbiv

3.43

2.51

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.70 kW

12.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.43

2.51

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2531 kWh

3822 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

159 %

117 %

Prated

11.00 kW

12.00 kW

SCOP

4.05

3.00

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.00 kW

7.80 kW

COP Tj = -7°C

3.40

2.55

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.20 kW

4.40 kW

COP Tj = +2°C

5.04

3.71

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

3.00 kW

2.90 kW

COP Tj = +7°C

6.04

4.61

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.30 kW

3.30 kW

COP Tj = 12°C

7.23

5.24

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

9.00 kW

9.60 kW

COP Tj = Tbiv

2.42

1.79

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

6.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.79

1.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.40 kW

5.30 kW

Annual energy consumption Qhe

6685 kWh

9548 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.00

9.60

COP Tj = -15°C (if TOL<-20°C)

2.42

1.79

Cdh Tj = -15 °C

0.990

0.990

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

110 %

COP

2.63

Heating up time

1:38 h:min

Standby power input

60.2 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

325 l

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

113 %

COP

2.71

Heating up time

1:40 h:min

Standby power input

57.8 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

323 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

87 %

COP

2.08

Heating up time

2:15 h:min

Standby power input

72.9 W

Reference hot water temperature

48.0 °C

Mixed water at 40°C

330 l

GRS-CQ14Pd/NhG4-E+SXTVD300LC/B-E
Configure model
Model name
GRS-CQ14Pd/NhG4-E+SXTVD300LC/B-E
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.20 kW

13.80 kW

El input

2.99 kW

4.67 kW

COP

4.75

2.95

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

147 %

Prated

13.00 kW

13.00 kW

SCOP

4.70

3.75

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

11.80 kW

COP Tj = -7°C

2.71

2.10

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

7.10 kW

6.80 kW

COP Tj = +2°C

4.39

3.81

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

4.40 kW

4.80 kW

COP Tj = +7°C

6.89

4.77

Cdh Tj = +7 °C

0.960

0.980

Pdh Tj = 12°C

3.50 kW

3.60 kW

COP Tj = 12°C

10.30

7.36

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

11.50 kW

11.80 kW

COP Tj = Tbiv

2.71

2.10

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.50 kW

9.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.38

1.74

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.50 kW

3.40 kW

Annual energy consumption Qhe

5682 kWh

7352 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

268 %

186 %

Prated

14.00 kW

14.00 kW

SCOP

6.78

4.73

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14.00 kW

14.20 kW

COP Tj = +2°C

3.38

2.30

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

8.40 kW

8.40 kW

COP Tj = +7°C

5.57

3.73

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

3.80 kW

4.20 kW

COP Tj = 12°C

9.32

6.75

Cdh Tj = +12 °C

0.940

0.960

Pdh Tj = Tbiv

14.00 kW

14.20 kW

COP Tj = Tbiv

3.38

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.00 kW

14.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.38

2.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2755 kWh

4008 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

184 %

132 %

Prated

12.00 kW

13.00 kW

SCOP

4.68

3.38

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.90 kW

7.80 kW

COP Tj = -7°C

3.88

2.77

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.50 kW

5.20 kW

COP Tj = +2°C

5.93

4.23

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

2.70 kW

2.90 kW

COP Tj = +7°C

7.20

5.24

Cdh Tj = +7 °C

0.930

0.950

Pdh Tj = 12°C

3.20 kW

3.30 kW

COP Tj = 12°C

8.98

7.55

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

9.70 kW

10.70 kW

COP Tj = Tbiv

2.72

1.99

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.90 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.89

1.18

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.10 kW

6.00 kW

Annual energy consumption Qhe

6257 kWh

9572 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.70

10.70

COP Tj = -15°C (if TOL<-20°C)

2.72

1.99

Cdh Tj = -15 °C

0.990

0.990

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

110 %

COP

2.63

Heating up time

1:38 h:min

Standby power input

60.2 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

325 l

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

113 %

COP

2.71

Heating up time

1:40 h:min

Standby power input

57.8 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

323 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

87 %

COP

2.08

Heating up time

2:15 h:min

Standby power input

72.9 W

Reference hot water temperature

48.0 °C

Mixed water at 40°C

330 l

GRS-CQ14Pd/NhG4-M+SXTVD300LC/B-M
Configure model
Model name
GRS-CQ14Pd/NhG4-M+SXTVD300LC/B-M
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.20 kW

13.80 kW

El input

3.09 kW

4.84 kW

COP

4.60

2.85

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

150 %

Prated

13.00 kW

13.00 kW

SCOP

4.55

3.83

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.60 kW

11.80 kW

COP Tj = -7°C

2.89

2.21

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

6.70 kW

6.90 kW

COP Tj = +2°C

4.50

3.65

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

4.50 kW

4.50 kW

COP Tj = +7°C

5.82

5.51

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

3.40 kW

3.50 kW

COP Tj = 12°C

7.53

7.06

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

11.60 kW

11.80 kW

COP Tj = Tbiv

2.89

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.10 kW

11.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.28

2.02

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.90 kW

1.40 kW

Annual energy consumption Qhe

5927 kWh

7176 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

240 %

159 %

Prated

14.00 kW

15.00 kW

SCOP

6.08

4.05

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13.70 kW

14.60 kW

COP Tj = +2°C

2.90

2.31

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

8.50 kW

8.80 kW

COP Tj = +7°C

5.36

3.29

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

3.70 kW

3.90 kW

COP Tj = 12°C

7.86

5.47

Cdh Tj = +12 °C

0.940

0.970

Pdh Tj = Tbiv

13.70 kW

14.60 kW

COP Tj = Tbiv

2.90

2.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.70 kW

14.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.31

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2995 kWh

4801 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

158 %

118 %

Prated

12.00 kW

13.00 kW

SCOP

4.03

3.03

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.00 kW

7.80 kW

COP Tj = -7°C

3.40

2.55

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.20 kW

4.40 kW

COP Tj = +2°C

5.04

3.71

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

3.00 kW

2.90 kW

COP Tj = +7°C

6.06

4.61

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.20 kW

3.30 kW

COP Tj = 12°C

6.17

5.03

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

9.70 kW

10.40 kW

COP Tj = Tbiv

2.38

1.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

6.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.79

1.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.40 kW

6.30 kW

Annual energy consumption Qhe

7293 kWh

10373 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.70

10.40

COP Tj = -15°C (if TOL<-20°C)

2.38

1.82

Cdh Tj = -15 °C

0.990

0.990

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

110 %

COP

2.63

Heating up time

1:38 h:min

Standby power input

60.2 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

325 l

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

113 %

COP

2.71

Heating up time

1:40 h:min

Standby power input

57.8 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

323 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

87 %

COP

2.08

Heating up time

2:15 h:min

Standby power input

72.9 W

Reference hot water temperature

48.0 °C

Mixed water at 40°C

330 l

GRS-CQ16Pd/NhG4-E+SXTVD300LC/B-E
Configure model
Model name
GRS-CQ16Pd/NhG4-E+SXTVD300LC/B-E
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.70 kW

15.40 kW

El input

3.45 kW

5.31 kW

COP

4.55

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

146 %

Prated

14.00 kW

14.00 kW

SCOP

4.68

3.73

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.20 kW

12.30 kW

COP Tj = -7°C

2.68

2.18

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

7.10 kW

6.80 kW

COP Tj = +2°C

4.39

3.81

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

4.70 kW

4.80 kW

COP Tj = +7°C

6.86

4.77

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

3.50 kW

3.60 kW

COP Tj = 12°C

10.30

7.36

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

12.20 kW

12.30 kW

COP Tj = Tbiv

2.68

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.20 kW

8.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.38

1.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.80 kW

5.50 kW

Annual energy consumption Qhe

6072 kWh

7675 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

267 %

186 %

Prated

14.00 kW

14.00 kW

SCOP

6.75

4.73

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14.20 kW

14.20 kW

COP Tj = +2°C

3.35

2.30

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

8.40 kW

8.40 kW

COP Tj = +7°C

5.57

3.73

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

3.80 kW

4.20 kW

COP Tj = 12°C

9.32

6.75

Cdh Tj = +12 °C

0.940

0.960

Pdh Tj = Tbiv

14.20 kW

14.20 kW

COP Tj = Tbiv

3.35

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.20 kW

14.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.35

2.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2800 kWh

4008 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

184 %

132 %

Prated

12.00 kW

13.00 kW

SCOP

4.68

3.38

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.90 kW

7.80 kW

COP Tj = -7°C

3.88

2.77

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.50 kW

5.20 kW

COP Tj = +2°C

5.93

4.23

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

2.70 kW

2.90 kW

COP Tj = +7°C

7.20

5.24

Cdh Tj = +7 °C

0.930

0.950

Pdh Tj = 12°C

3.20 kW

3.30 kW

COP Tj = 12°C

8.98

7.55

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

9.70 kW

10.70 kW

COP Tj = Tbiv

2.71

1.99

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.90 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.89

1.18

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.10 kW

6.00 kW

Annual energy consumption Qhe

6257 kWh

9572 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.70

10.70

COP Tj = -15°C (if TOL<-20°C)

2.71

1.99

Cdh Tj = -15 °C

0.990

0.990

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

110 %

COP

2.63

Heating up time

1:38 h:min

Standby power input

60.2 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

325 l

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

113 %

COP

2.71

Heating up time

1:40 h:min

Standby power input

57.8 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

323 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

87 %

COP

2.08

Heating up time

2:15 h:min

Standby power input

72.9 W

Reference hot water temperature

48.0 °C

Mixed water at 40°C

330 l

GRS-CQ16Pd/NhG4-M+SXTVD300LC/B-M
Configure model
Model name
GRS-CQ16Pd/NhG4-M+SXTVD300LC/B-M
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.70 kW

15.40 kW

El input

3.57 kW

5.60 kW

COP

4.40

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

150 %

Prated

13.00 kW

14.00 kW

SCOP

4.55

3.83

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.60 kW

12.10 kW

COP Tj = -7°C

2.89

2.16

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

6.70 kW

6.90 kW

COP Tj = +2°C

4.50

3.65

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

4.50 kW

4.50 kW

COP Tj = +7°C

5.82

5.51

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

3.40 kW

3.50 kW

COP Tj = 12°C

7.53

7.06

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

11.60 kW

12.10 kW

COP Tj = Tbiv

2.89

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.10 kW

11.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.29

2.02

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.90 kW

2.50 kW

Annual energy consumption Qhe

5927 kWh

7404 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

241 %

159 %

Prated

14.00 kW

15.00 kW

SCOP

6.10

4.05

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13.70 kW

14.60 kW

COP Tj = +2°C

2.90

2.31

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

8.50 kW

8.80 kW

COP Tj = +7°C

5.36

3.29

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

3.70 kW

3.90 kW

COP Tj = 12°C

7.86

5.47

Cdh Tj = +12 °C

0.950

0.970

Pdh Tj = Tbiv

13.70 kW

14.60 kW

COP Tj = Tbiv

2.90

2.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.70 kW

14.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.31

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2995 kWh

4801 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

158 %

118 %

Prated

12.00 kW

13.00 kW

SCOP

4.03

3.03

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.00 kW

7.80 kW

COP Tj = -7°C

3.40

2.55

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.20 kW

4.40 kW

COP Tj = +2°C

5.04

3.71

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

3.00 kW

2.90 kW

COP Tj = +7°C

6.06

4.61

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.20 kW

3.30 kW

COP Tj = 12°C

6.17

5.02

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

9.70 kW

10.40 kW

COP Tj = Tbiv

2.38

1.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

6.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.79

1.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.40 kW

6.30 kW

Annual energy consumption Qhe

7293 kWh

10373 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.70

10.40

COP Tj = -15°C (if TOL<-20°C)

2.38

1.82

Cdh Tj = -15 °C

0.990

0.990

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

110 %

COP

2.63

Heating up time

1:38 h:min

Standby power input

60.2 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

325 l

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

113 %

COP

2.71

Heating up time

1:40 h:min

Standby power input

57.8 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

323 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

87 %

COP

2.08

Heating up time

2:15 h:min

Standby power input

72.9 W

Reference hot water temperature

48.0 °C

Mixed water at 40°C

330 l