1,600 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.20 kW
7.81 kW
El input
1.54 kW
2.44 kW
COP
5.32
3.20
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
145 %
Prated
8.00 kW
9.00 kW
SCOP
4.50
3.70
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.40 kW
8.30 kW
COP Tj = -7°C
3.12
2.33
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.40 kW
5.20 kW
COP Tj = +2°C
4.44
3.57
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
3.00 kW
3.30 kW
COP Tj = +7°C
5.31
4.96
Cdh Tj = +7 °C
0.950
0.970
Pdh Tj = 12°C
3.20 kW
3.00 kW
COP Tj = 12°C
7.69
6.56
Cdh Tj = +12 °C
0.940
0.960
Pdh Tj = Tbiv
7.40 kW
8.30 kW
COP Tj = Tbiv
3.12
2.33
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.80 kW
8.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.77
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.20 kW
0.30 kW
Annual energy consumption Qhe
3827 kWh
5206 kWh
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
257 %
190 %
Prated
9.00 kW
9.00 kW
SCOP
6.50
4.83
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
9.40 kW
8.60 kW
COP Tj = +2°C
3.85
2.59
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
6.10 kW
6.30 kW
COP Tj = +7°C
6.07
4.21
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
3.20 kW
3.00 kW
COP Tj = 12°C
7.83
6.32
Cdh Tj = +12 °C
0.950
0.960
Pdh Tj = Tbiv
9.40 kW
8.60 kW
COP Tj = Tbiv
3.85
2.59
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.40 kW
8.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.85
2.58
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1942 kWh
2372 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
165 %
125 %
Prated
9.00 kW
8.00 kW
SCOP
4.20
3.20
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.70 kW
5.20 kW
COP Tj = -7°C
3.45
2.83
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.50 kW
2.90 kW
COP Tj = +2°C
5.16
3.73
Cdh Tj = +2 °C
0.970
0.980
Pdh Tj = +7°C
2.60 kW
2.40 kW
COP Tj = +7°C
6.69
4.44
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
3.00 kW
3.00 kW
COP Tj = 12°C
7.53
7.10
Cdh Tj = +12 °C
0.950
0.960
Pdh Tj = Tbiv
7.40 kW
6.70 kW
COP Tj = Tbiv
2.70
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.10 kW
4.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.87
1.06
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.90 kW
3.90 kW
Annual energy consumption Qhe
5303 kWh
6322 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.40
6.70
COP Tj = -15°C (if TOL<-20°C)
2.70
2.10
Cdh Tj = -15 °C
0.990
0.990
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
123 %
COP
2.93
Heating up time
2:04 h:min
Standby power input
58.5 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
325 l
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
123 %
COP
2.93
Heating up time
2:07 h:min
Standby power input
58.6 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
325 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
101 %
COP
2.41
Heating up time
2:30 h:min
Standby power input
72.9 W
Reference hot water temperature
48.0 °C
Mixed water at 40°C
325 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.20 kW
7.81 kW
El input
1.54 kW
2.44 kW
COP
5.32
3.20
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
145 %
Prated
8.00 kW
9.00 kW
SCOP
4.50
3.70
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.40 kW
8.30 kW
COP Tj = -7°C
3.12
2.33
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.40 kW
5.20 kW
COP Tj = +2°C
4.44
3.57
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
3.00 kW
3.30 kW
COP Tj = +7°C
5.31
4.96
Cdh Tj = +7 °C
0.950
0.970
Pdh Tj = 12°C
3.20 kW
3.00 kW
COP Tj = 12°C
7.69
6.56
Cdh Tj = +12 °C
0.940
0.960
Pdh Tj = Tbiv
7.40 kW
8.30 kW
COP Tj = Tbiv
3.12
2.33
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.80 kW
8.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.77
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.20 kW
0.30 kW
Annual energy consumption Qhe
3827 kWh
5206 kWh
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
257 %
190 %
Prated
9.00 kW
9.00 kW
SCOP
6.50
4.83
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
9.40 kW
8.60 kW
COP Tj = +2°C
3.85
2.59
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
6.10 kW
6.30 kW
COP Tj = +7°C
6.07
4.21
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
3.20 kW
3.00 kW
COP Tj = 12°C
7.83
6.32
Cdh Tj = +12 °C
0.950
0.960
Pdh Tj = Tbiv
9.40 kW
8.60 kW
COP Tj = Tbiv
3.85
2.59
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.40 kW
8.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.85
2.58
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1942 kWh
2372 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
165 %
125 %
Prated
9.00 kW
8.00 kW
SCOP
4.20
3.20
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.70 kW
5.20 kW
COP Tj = -7°C
3.45
2.83
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.50 kW
2.90 kW
COP Tj = +2°C
5.16
3.73
Cdh Tj = +2 °C
0.970
0.980
Pdh Tj = +7°C
2.60 kW
2.40 kW
COP Tj = +7°C
6.69
4.44
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
3.00 kW
3.00 kW
COP Tj = 12°C
7.53
7.10
Cdh Tj = +12 °C
0.950
0.960
Pdh Tj = Tbiv
7.40 kW
6.70 kW
COP Tj = Tbiv
2.70
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.10 kW
4.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.87
1.06
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.90 kW
3.90 kW
Annual energy consumption Qhe
5303 kWh
6322 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.40
6.70
COP Tj = -15°C (if TOL<-20°C)
2.70
2.10
Cdh Tj = -15 °C
0.990
0.990
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
123 %
COP
2.93
Heating up time
2:04 h:min
Standby power input
58.5 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
325 l
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
123 %
COP
2.93
Heating up time
2:07 h:min
Standby power input
58.6 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
325 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
101 %
COP
2.41
Heating up time
2:30 h:min
Standby power input
72.9 W
Reference hot water temperature
48.0 °C
Mixed water at 40°C
325 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.20 kW
7.81 kW
El input
1.62 kW
2.55 kW
COP
5.06
3.06
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
135 %
Prated
8.00 kW
9.00 kW
SCOP
4.48
3.45
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.40 kW
7.80 kW
COP Tj = -7°C
3.12
2.14
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.20 kW
5.00 kW
COP Tj = +2°C
4.17
3.36
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.84 kW
3.30 kW
COP Tj = +7°C
5.92
4.53
Cdh Tj = +7 °C
0.950
0.970
Pdh Tj = 12°C
3.20 kW
3.00 kW
COP Tj = 12°C
7.18
5.44
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
7.40 kW
7.80 kW
COP Tj = Tbiv
3.12
2.14
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.00 kW
8.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.84
2.07
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.40 kW
Annual energy consumption Qhe
3882 kWh
5261 kWh
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
226 %
168 %
Prated
9.00 kW
9.00 kW
SCOP
5.73
4.28
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
8.60 kW
8.90 kW
COP Tj = +2°C
2.93
2.12
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.40 kW
6.30 kW
COP Tj = +7°C
5.40
3.99
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
3.00 kW
3.00 kW
COP Tj = 12°C
7.04
5.29
Cdh Tj = +12 °C
0.950
0.960
Pdh Tj = Tbiv
8.60 kW
8.90 kW
COP Tj = Tbiv
2.93
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.60 kW
8.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.93
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2001 kWh
2751 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
142 %
120 %
Prated
9.00 kW
8.00 kW
SCOP
3.63
3.08
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.40 kW
5.10 kW
COP Tj = -7°C
2.75
2.75
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.20 kW
3.00 kW
COP Tj = +2°C
4.52
3.40
Cdh Tj = +2 °C
0.980
0.970
Pdh Tj = +7°C
2.60 kW
3.20 kW
COP Tj = +7°C
5.63
4.61
Cdh Tj = +7 °C
0.940
0.960
Pdh Tj = 12°C
3.20 kW
3.00 kW
COP Tj = 12°C
7.01
5.79
Cdh Tj = +12 °C
0.950
0.950
Pdh Tj = Tbiv
7.20 kW
6.80 kW
COP Tj = Tbiv
2.63
2.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.10 kW
4.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.87
1.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.90 kW
3.60 kW
Annual energy consumption Qhe
5935 kWh
6706 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.20
6.80
COP Tj = -15°C (if TOL<-20°C)
2.63
2.20
Cdh Tj = -15 °C
0.990
0.990
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
123 %
COP
2.93
Heating up time
2:04 h:min
Standby power input
58.5 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
325 l
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
123 %
COP
2.93
Heating up time
2:07 h:min
Standby power input
58.6 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
325 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
101 %
COP
2.41
Heating up time
2:30 h:min
Standby power input
72.9 W
Reference hot water temperature
48.0 °C
Mixed water at 40°C
325 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.20 kW
7.81 kW
El input
1.62 kW
2.55 kW
COP
5.06
3.06
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
135 %
Prated
8.00 kW
9.00 kW
SCOP
4.48
3.45
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.40 kW
7.80 kW
COP Tj = -7°C
3.12
2.14
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.20 kW
5.00 kW
COP Tj = +2°C
4.17
3.36
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.84 kW
3.30 kW
COP Tj = +7°C
5.92
4.53
Cdh Tj = +7 °C
0.950
0.970
Pdh Tj = 12°C
3.20 kW
3.00 kW
COP Tj = 12°C
7.18
5.44
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
7.40 kW
7.80 kW
COP Tj = Tbiv
3.12
2.14
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.00 kW
8.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.84
2.07
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.40 kW
Annual energy consumption Qhe
3882 kWh
5261 kWh
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
226 %
168 %
Prated
9.00 kW
9.00 kW
SCOP
5.73
4.28
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
8.60 kW
8.90 kW
COP Tj = +2°C
2.93
2.12
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.40 kW
6.30 kW
COP Tj = +7°C
5.40
3.99
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
3.00 kW
3.00 kW
COP Tj = 12°C
7.04
5.29
Cdh Tj = +12 °C
0.950
0.960
Pdh Tj = Tbiv
8.60 kW
8.90 kW
COP Tj = Tbiv
2.93
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.60 kW
8.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.93
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2001 kWh
2751 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
142 %
120 %
Prated
9.00 kW
8.00 kW
SCOP
3.63
3.08
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.40 kW
5.10 kW
COP Tj = -7°C
2.75
2.75
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.20 kW
3.00 kW
COP Tj = +2°C
4.52
3.40
Cdh Tj = +2 °C
0.980
0.970
Pdh Tj = +7°C
2.60 kW
3.20 kW
COP Tj = +7°C
5.63
4.61
Cdh Tj = +7 °C
0.940
0.960
Pdh Tj = 12°C
3.20 kW
3.00 kW
COP Tj = 12°C
7.01
5.79
Cdh Tj = +12 °C
0.950
0.950
Pdh Tj = Tbiv
7.20 kW
6.80 kW
COP Tj = Tbiv
2.63
2.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.10 kW
4.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.87
1.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.90 kW
3.60 kW
Annual energy consumption Qhe
5935 kWh
6706 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.20
6.80
COP Tj = -15°C (if TOL<-20°C)
2.63
2.20
Cdh Tj = -15 °C
0.990
0.990
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
123 %
COP
2.93
Heating up time
2:04 h:min
Standby power input
58.5 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
325 l
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
123 %
COP
2.93
Heating up time
2:07 h:min
Standby power input
58.6 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
325 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
101 %
COP
2.41
Heating up time
2:30 h:min
Standby power input
72.9 W
Reference hot water temperature
48.0 °C
Mixed water at 40°C
325 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.20 kW
10.30 kW
El input
2.02 kW
3.30 kW
COP
5.05
3.12
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
152 %
Prated
9.00 kW
10.00 kW
SCOP
4.48
3.88
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.00 kW
9.10 kW
COP Tj = -7°C
2.90
2.42
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.60 kW
5.30 kW
COP Tj = +2°C
4.41
3.62
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
4.80 kW
3.40 kW
COP Tj = +7°C
5.89
5.47
Cdh Tj = +7 °C
0.950
0.970
Pdh Tj = 12°C
3.20 kW
3.40 kW
COP Tj = 12°C
6.97
7.20
Cdh Tj = +12 °C
0.940
0.960
Pdh Tj = Tbiv
8.00 kW
9.10 kW
COP Tj = Tbiv
2.90
2.42
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.50 kW
9.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
2.05
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.50 kW
0.50 kW
Annual energy consumption Qhe
4163 kWh
5486 kWh
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
223 %
169 %
Prated
10.00 kW
10.00 kW
SCOP
5.65
4.30
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
9.60 kW
10.10 kW
COP Tj = +2°C
3.47
2.55
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.90 kW
6.50 kW
COP Tj = +7°C
5.45
3.90
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
3.00 kW
2.90 kW
COP Tj = 12°C
6.55
5.19
Cdh Tj = +12 °C
0.950
0.960
Pdh Tj = Tbiv
9.60 kW
10.10 kW
COP Tj = Tbiv
3.47
2.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.60 kW
10.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.47
2.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2266 kWh
3157 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
152 %
119 %
Prated
10.00 kW
9.00 kW
SCOP
3.88
3.05
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.10 kW
5.50 kW
COP Tj = -7°C
3.23
2.77
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.40 kW
3.10 kW
COP Tj = +2°C
4.72
3.48
Cdh Tj = +2 °C
0.970
0.980
Pdh Tj = +7°C
2.70 kW
3.00 kW
COP Tj = +7°C
5.59
4.17
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
3.20 kW
3.10 kW
COP Tj = 12°C
6.85
5.42
Cdh Tj = +12 °C
0.950
0.960
Pdh Tj = Tbiv
8.00 kW
7.50 kW
COP Tj = Tbiv
2.50
2.10
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.00 kW
5.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.86
1.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.00 kW
3.80 kW
Annual energy consumption Qhe
6262 kWh
7415 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.00
7.50
COP Tj = -15°C (if TOL<-20°C)
2.50
2.10
Cdh Tj = -15 °C
0.990
0.990
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
123 %
COP
2.93
Heating up time
2:04 h:min
Standby power input
58.5 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
325 l
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
123 %
COP
2.93
Heating up time
2:07 h:min
Standby power input
58.6 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
325 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
101 %
COP
2.41
Heating up time
2:30 h:min
Standby power input
72.9 W
Reference hot water temperature
48.0 °C
Mixed water at 40°C
325 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.20 kW
10.30 kW
El input
2.02 kW
3.30 kW
COP
5.05
3.12
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
152 %
Prated
9.00 kW
10.00 kW
SCOP
4.48
3.88
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.00 kW
9.10 kW
COP Tj = -7°C
2.90
2.42
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.60 kW
5.30 kW
COP Tj = +2°C
4.41
3.62
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
4.80 kW
3.40 kW
COP Tj = +7°C
5.89
5.47
Cdh Tj = +7 °C
0.950
0.970
Pdh Tj = 12°C
3.20 kW
3.40 kW
COP Tj = 12°C
6.97
7.20
Cdh Tj = +12 °C
0.940
0.960
Pdh Tj = Tbiv
8.00 kW
9.10 kW
COP Tj = Tbiv
2.90
2.42
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.50 kW
9.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
2.05
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.50 kW
0.50 kW
Annual energy consumption Qhe
4163 kWh
5486 kWh
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
223 %
169 %
Prated
10.00 kW
10.00 kW
SCOP
5.65
4.30
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
9.60 kW
10.10 kW
COP Tj = +2°C
3.47
2.55
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.90 kW
6.50 kW
COP Tj = +7°C
5.45
3.90
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
3.00 kW
2.90 kW
COP Tj = 12°C
6.55
5.19
Cdh Tj = +12 °C
0.950
0.960
Pdh Tj = Tbiv
9.60 kW
10.10 kW
COP Tj = Tbiv
3.47
2.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.60 kW
10.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.47
2.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2266 kWh
3157 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
152 %
119 %
Prated
10.00 kW
9.00 kW
SCOP
3.88
3.05
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.10 kW
5.50 kW
COP Tj = -7°C
3.23
2.77
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.40 kW
3.10 kW
COP Tj = +2°C
4.72
3.48
Cdh Tj = +2 °C
0.970
0.980
Pdh Tj = +7°C
2.70 kW
3.00 kW
COP Tj = +7°C
5.59
4.17
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
3.20 kW
3.10 kW
COP Tj = 12°C
6.85
5.42
Cdh Tj = +12 °C
0.950
0.960
Pdh Tj = Tbiv
8.00 kW
7.50 kW
COP Tj = Tbiv
2.50
2.10
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.00 kW
5.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.86
1.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.00 kW
3.80 kW
Annual energy consumption Qhe
6262 kWh
7415 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.00
7.50
COP Tj = -15°C (if TOL<-20°C)
2.50
2.10
Cdh Tj = -15 °C
0.990
0.990
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
123 %
COP
2.93
Heating up time
2:04 h:min
Standby power input
58.5 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
325 l
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
123 %
COP
2.93
Heating up time
2:07 h:min
Standby power input
58.6 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
325 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
101 %
COP
2.41
Heating up time
2:30 h:min
Standby power input
72.9 W
Reference hot water temperature
48.0 °C
Mixed water at 40°C
325 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.20 kW
10.30 kW
El input
2.06 kW
3.38 kW
COP
4.95
3.05
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
189 %
140 %
Prated
9.00 kW
10.00 kW
SCOP
4.80
3.58
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.30 kW
9.00 kW
COP Tj = -7°C
3.15
2.45
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.60 kW
5.20 kW
COP Tj = +2°C
4.32
3.44
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
3.30 kW
3.50 kW
COP Tj = +7°C
7.46
4.63
Cdh Tj = +7 °C
0.950
0.970
Pdh Tj = 12°C
3.20 kW
2.90 kW
COP Tj = 12°C
7.44
5.21
Cdh Tj = +12 °C
0.940
0.960
Pdh Tj = Tbiv
8.30 kW
9.00 kW
COP Tj = Tbiv
3.15
2.45
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.30 kW
9.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
2.15
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.70 kW
0.40 kW
Annual energy consumption Qhe
4069 kWh
5907 kWh
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
223 %
165 %
Prated
10.00 kW
10.00 kW
SCOP
5.65
4.20
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.10 kW
10.10 kW
COP Tj = +2°C
3.70
2.55
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
6.00 kW
6.00 kW
COP Tj = +7°C
5.63
3.63
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
3.00 kW
3.30 kW
COP Tj = 12°C
6.22
5.30
Cdh Tj = +12 °C
0.950
0.960
Pdh Tj = Tbiv
10.10 kW
10.10 kW
COP Tj = Tbiv
3.70
2.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.10 kW
10.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.70
2.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2399 kWh
3236 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
150 %
124 %
Prated
10.00 kW
9.00 kW
SCOP
3.83
3.18
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.70 kW
5.80 kW
COP Tj = -7°C
2.95
2.95
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.40 kW
3.50 kW
COP Tj = +2°C
4.71
3.50
Cdh Tj = +2 °C
0.970
0.980
Pdh Tj = +7°C
2.80 kW
2.70 kW
COP Tj = +7°C
6.23
4.83
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
3.20 kW
3.40 kW
COP Tj = 12°C
6.85
6.08
Cdh Tj = +12 °C
0.950
0.960
Pdh Tj = Tbiv
7.80 kW
7.60 kW
COP Tj = Tbiv
2.73
2.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.00 kW
4.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.86
1.06
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.00 kW
4.90 kW
Annual energy consumption Qhe
6194 kWh
7206 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.80
7.60
COP Tj = -15°C (if TOL<-20°C)
2.73
2.20
Cdh Tj = -15 °C
0.990
0.990
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
123 %
COP
2.93
Heating up time
2:04 h:min
Standby power input
58.5 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
325 l
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
123 %
COP
2.93
Heating up time
2:07 h:min
Standby power input
58.6 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
325 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
101 %
COP
2.41
Heating up time
2:30 h:min
Standby power input
72.9 W
Reference hot water temperature
48.0 °C
Mixed water at 40°C
325 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.20 kW
10.30 kW
El input
2.06 kW
3.38 kW
COP
4.95
3.05
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
189 %
140 %
Prated
9.00 kW
10.00 kW
SCOP
4.80
3.58
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.30 kW
9.00 kW
COP Tj = -7°C
3.15
2.45
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.60 kW
5.20 kW
COP Tj = +2°C
4.32
3.44
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
3.30 kW
3.50 kW
COP Tj = +7°C
7.46
4.63
Cdh Tj = +7 °C
0.950
0.970
Pdh Tj = 12°C
3.20 kW
2.90 kW
COP Tj = 12°C
7.44
5.21
Cdh Tj = +12 °C
0.940
0.960
Pdh Tj = Tbiv
8.30 kW
9.00 kW
COP Tj = Tbiv
3.15
2.45
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.30 kW
9.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
2.15
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.70 kW
0.40 kW
Annual energy consumption Qhe
4069 kWh
5907 kWh
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
223 %
165 %
Prated
10.00 kW
10.00 kW
SCOP
5.65
4.20
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.10 kW
10.10 kW
COP Tj = +2°C
3.70
2.55
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
6.00 kW
6.00 kW
COP Tj = +7°C
5.63
3.63
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
3.00 kW
3.30 kW
COP Tj = 12°C
6.22
5.30
Cdh Tj = +12 °C
0.950
0.960
Pdh Tj = Tbiv
10.10 kW
10.10 kW
COP Tj = Tbiv
3.70
2.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.10 kW
10.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.70
2.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2399 kWh
3236 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
150 %
124 %
Prated
10.00 kW
9.00 kW
SCOP
3.83
3.18
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.70 kW
5.80 kW
COP Tj = -7°C
2.95
2.95
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.40 kW
3.50 kW
COP Tj = +2°C
4.71
3.50
Cdh Tj = +2 °C
0.970
0.980
Pdh Tj = +7°C
2.80 kW
2.70 kW
COP Tj = +7°C
6.23
4.83
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
3.20 kW
3.40 kW
COP Tj = 12°C
6.85
6.08
Cdh Tj = +12 °C
0.950
0.960
Pdh Tj = Tbiv
7.80 kW
7.60 kW
COP Tj = Tbiv
2.73
2.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.00 kW
4.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.86
1.06
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.00 kW
4.90 kW
Annual energy consumption Qhe
6194 kWh
7206 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.80
7.60
COP Tj = -15°C (if TOL<-20°C)
2.73
2.20
Cdh Tj = -15 °C
0.990
0.990
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
123 %
COP
2.93
Heating up time
2:04 h:min
Standby power input
58.5 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
325 l
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
123 %
COP
2.93
Heating up time
2:07 h:min
Standby power input
58.6 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
325 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
101 %
COP
2.41
Heating up time
2:30 h:min
Standby power input
72.9 W
Reference hot water temperature
48.0 °C
Mixed water at 40°C
325 l