1,100 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.30 kW
4.36 kW
El input
0.83 kW
1.47 kW
COP
5.18
2.97
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
236 %
156 %
Prated
5.50 kW
5.00 kW
SCOP
5.98
3.97
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.37 kW
4.87 kW
COP Tj = +2°C
3.94
2.51
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.54 kW
3.21 kW
COP Tj = +7°C
5.92
3.68
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.57 kW
1.43 kW
COP Tj = 12°C
7.91
5.15
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
3.54 kW
3.21 kW
COP Tj = Tbiv
5.92
3.68
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.37 kW
4.87 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.94
2.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
30 W
30 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.13 kW
0.13 kW
Annual energy consumption Qhe
1229 kWh
1684 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
131 %
Prated
5.50 kW
5.50 kW
SCOP
4.83
3.34
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.87 kW
4.87 kW
COP Tj = -7°C
3.23
1.96
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.96 kW
2.96 kW
COP Tj = +2°C
4.84
3.48
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
1.90 kW
1.90 kW
COP Tj = +7°C
6.46
4.28
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
0.85 kW
0.85 kW
COP Tj = 12°C
9.62
6.58
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
4.87 kW
4.87 kW
COP Tj = Tbiv
3.23
1.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.34 kW
3.42 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.86
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
30 W
30 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.16 kW
2.08 kW
Annual energy consumption Qhe
2355 kWh
3399 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.25 kW
6.40 kW
El input
1.30 kW
2.13 kW
COP
4.81
3.00
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
254 %
157 %
Prated
6.10 kW
5.10 kW
SCOP
6.41
3.99
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.85 kW
4.85 kW
COP Tj = +2°C
3.91
2.48
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.93 kW
3.31 kW
COP Tj = +7°C
5.89
3.67
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.79 kW
1.59 kW
COP Tj = 12°C
8.20
5.29
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
3.92 kW
3.28 kW
COP Tj = Tbiv
5.89
3.67
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.85 kW
4.85 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.91
2.48
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
30 W
30 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.25 kW
0.25 kW
Annual energy consumption Qhe
1270 kWh
1708 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
194 %
134 %
Prated
6.80 kW
6.30 kW
SCOP
4.92
3.41
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.00 kW
5.58 kW
COP Tj = -7°C
3.24
2.20
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.77 kW
3.40 kW
COP Tj = +2°C
4.98
3.42
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.42 kW
2.19 kW
COP Tj = +7°C
6.38
4.36
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.02 kW
1.73 kW
COP Tj = 12°C
9.67
6.89
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.00 kW
5.58 kW
COP Tj = Tbiv
3.24
2.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.42 kW
4.03 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.90
1.85
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
30 W
30 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.38 kW
2.30 kW
Annual energy consumption Qhe
2853 kWh
3812 kWh