14,000 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
49.95 kW
46.5 kW
El input
11.33 kW
17.22 kW
COP
4.41
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
215 %
152 %
Prated
39.72 kW
31.49 kW
SCOP
5.45
3.87
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
39.72 kW
31.49 kW
COP Tj = +2°C
3.45
2.08
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
25.86 kW
22.84 kW
COP Tj = +7°C
5.05
3.5
Cdh Tj = +7 °C
0.9
0.9
Pdh Tj = 12°C
29.3 kW
27.53 kW
COP Tj = 12°C
6.79
5.2
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
39.72 kW
31.49 kW
COP Tj = Tbiv
3.45
2.08
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
39.72 kW
31.49 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.45
2.08
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
9730 kWh
10873 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
143 %
107 %
Prated
26.65 kW
27.77 kW
SCOP
3.65
2.76
Tbiv
-15 °C
-12 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
16.28 kW
16.53 kW
COP Tj = -7°C
3.16
2.32
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
21.72 kW
20.6 kW
COP Tj = +2°C
4.91
3.88
Cdh Tj = +2 °C
0.96
0.96
Pdh Tj = +7°C
25.62 kW
24.5 kW
COP Tj = +7°C
5.94
4.96
Cdh Tj = +7 °C
0.96
0.96
Pdh Tj = 12°C
29.38 kW
28.5 kW
COP Tj = 12°C
6.87
6.16
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
21.74 kW
20.46 kW
COP Tj = Tbiv
1.96
1.6
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
17.95 kW
18.11 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.65
1.43
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
26.65 kW
27.77 kW
Annual energy consumption Qhe
17986 kWh
24781 kWh
Pdh Tj = -15°C (if TOL<-20°C)
17.95
18.11
COP Tj = -15°C (if TOL<-20°C)
1.65
1.43
Cdh Tj = -15 °C
0.9
0.9
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
126 %
Prated
34.1 kW
33.2 kW
SCOP
4.33
3.24
Tbiv
-7 °C
-6 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
30.13 kW
26.60 kW
COP Tj = -7°C
2.81
1.87
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
21.36 kW
18.78 kW
COP Tj = +2°C
4.47
3.26
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
25.09 kW
23.27 kW
COP Tj = +7°C
5.61
4.49
Cdh Tj = +7 °C
0.95
0.98
Pdh Tj = 12°C
29.72 kW
28.35 kW
COP Tj = 12°C
7.27
6.23
Cdh Tj = +12 °C
0.95
0.98
Pdh Tj = Tbiv
30.13 kW
28.13 kW
COP Tj = Tbiv
2.81
2.00
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
28.65 kW
14.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.60
1.10
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.40 kW
19.24 kW
Annual energy consumption Qhe
16247 kWh
21225 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
49.95 kW
46.5 kW
El input
11.33 kW
17.22 kW
COP
4.41
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
215 %
152 %
Prated
39.72 kW
31.49 kW
SCOP
5.45
3.87
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
39.72 kW
31.49 kW
COP Tj = +2°C
3.45
2.08
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
25.86 kW
22.84 kW
COP Tj = +7°C
5.05
3.5
Cdh Tj = +7 °C
0.9
0.9
Pdh Tj = 12°C
29.3 kW
27.53 kW
COP Tj = 12°C
6.79
5.2
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
39.72 kW
31.49 kW
COP Tj = Tbiv
3.45
2.08
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
39.72 kW
31.49 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.45
2.08
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
9730 kWh
10873 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
143 %
107 %
Prated
26.65 kW
27.77 kW
SCOP
3.65
2.76
Tbiv
-15 °C
-12 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
16.28 kW
16.53 kW
COP Tj = -7°C
3.16
2.32
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
21.72 kW
20.6 kW
COP Tj = +2°C
4.91
3.88
Cdh Tj = +2 °C
0.96
0.96
Pdh Tj = +7°C
25.62 kW
24.5 kW
COP Tj = +7°C
5.94
4.96
Cdh Tj = +7 °C
0.96
0.96
Pdh Tj = 12°C
29.38 kW
28.5 kW
COP Tj = 12°C
6.87
6.16
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
21.74 kW
20.46 kW
COP Tj = Tbiv
1.96
1.6
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
17.95 kW
18.11 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.65
1.43
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
26.65 kW
27.77 kW
Annual energy consumption Qhe
17986 kWh
24781 kWh
Pdh Tj = -15°C (if TOL<-20°C)
17.95
18.11
COP Tj = -15°C (if TOL<-20°C)
1.65
1.43
Cdh Tj = -15 °C
0.9
0.9
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
126 %
Prated
34.1 kW
33.2 kW
SCOP
4.33
3.24
Tbiv
-7 °C
-6 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
30.13 kW
26.60 kW
COP Tj = -7°C
2.81
1.87
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
21.36 kW
18.78 kW
COP Tj = +2°C
4.47
3.26
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
25.09 kW
23.27 kW
COP Tj = +7°C
5.61
4.49
Cdh Tj = +7 °C
0.95
0.98
Pdh Tj = 12°C
29.72 kW
28.35 kW
COP Tj = 12°C
7.27
6.23
Cdh Tj = +12 °C
0.95
0.98
Pdh Tj = Tbiv
30.13 kW
28.13 kW
COP Tj = Tbiv
2.81
2.00
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
28.65 kW
14.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.60
1.10
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.40 kW
19.24 kW
Annual energy consumption Qhe
16247 kWh
21225 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
49.95 kW
46.5 kW
El input
11.33 kW
17.22 kW
COP
4.41
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
215 %
152 %
Prated
39.72 kW
31.49 kW
SCOP
5.45
3.87
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
39.72 kW
31.49 kW
COP Tj = +2°C
3.45
2.08
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
25.86 kW
22.84 kW
COP Tj = +7°C
5.05
3.5
Cdh Tj = +7 °C
0.9
0.9
Pdh Tj = 12°C
29.3 kW
27.53 kW
COP Tj = 12°C
6.79
5.2
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
39.72 kW
31.49 kW
COP Tj = Tbiv
3.45
2.08
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
39.72 kW
31.49 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.45
2.08
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
9730 kWh
10873 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
143 %
107 %
Prated
26.65 kW
27.77 kW
SCOP
3.65
2.76
Tbiv
-15 °C
-12 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
16.28 kW
16.53 kW
COP Tj = -7°C
3.16
2.32
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
21.72 kW
20.6 kW
COP Tj = +2°C
4.91
3.88
Cdh Tj = +2 °C
0.96
0.96
Pdh Tj = +7°C
25.62 kW
24.5 kW
COP Tj = +7°C
5.94
4.96
Cdh Tj = +7 °C
0.96
0.96
Pdh Tj = 12°C
29.38 kW
28.5 kW
COP Tj = 12°C
6.87
6.16
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
21.74 kW
20.46 kW
COP Tj = Tbiv
1.96
1.6
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
17.95 kW
18.11 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.65
1.43
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
26.65 kW
27.77 kW
Annual energy consumption Qhe
17986 kWh
24781 kWh
Pdh Tj = -15°C (if TOL<-20°C)
17.95
18.11
COP Tj = -15°C (if TOL<-20°C)
1.65
1.43
Cdh Tj = -15 °C
0.9
0.9
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
126 %
Prated
34.1 kW
33.2 kW
SCOP
4.33
3.24
Tbiv
-7 °C
-6 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
30.13 kW
26.60 kW
COP Tj = -7°C
2.81
1.87
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
21.36 kW
18.78 kW
COP Tj = +2°C
4.47
3.26
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
25.09 kW
23.27 kW
COP Tj = +7°C
5.61
4.49
Cdh Tj = +7 °C
0.95
0.98
Pdh Tj = 12°C
29.72 kW
28.35 kW
COP Tj = 12°C
7.27
6.23
Cdh Tj = +12 °C
0.95
0.98
Pdh Tj = Tbiv
30.13 kW
28.13 kW
COP Tj = Tbiv
2.81
2.00
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
28.65 kW
14.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.60
1.10
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.40 kW
19.24 kW
Annual energy consumption Qhe
16247 kWh
21225 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
49.95 kW
46.5 kW
El input
11.33 kW
17.22 kW
COP
4.41
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
215 %
152 %
Prated
39.72 kW
31.49 kW
SCOP
5.45
3.87
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
39.72 kW
31.49 kW
COP Tj = +2°C
3.45
2.08
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
25.86 kW
22.84 kW
COP Tj = +7°C
5.05
3.5
Cdh Tj = +7 °C
0.9
0.9
Pdh Tj = 12°C
29.3 kW
27.53 kW
COP Tj = 12°C
6.79
5.2
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
39.72 kW
31.49 kW
COP Tj = Tbiv
3.45
2.08
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
39.72 kW
31.49 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.45
2.08
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
9730 kWh
10873 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
143 %
107 %
Prated
26.65 kW
27.77 kW
SCOP
3.65
2.76
Tbiv
-15 °C
-12 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
16.28 kW
16.53 kW
COP Tj = -7°C
3.16
2.32
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
21.72 kW
20.6 kW
COP Tj = +2°C
4.91
3.88
Cdh Tj = +2 °C
0.96
0.96
Pdh Tj = +7°C
25.62 kW
24.5 kW
COP Tj = +7°C
5.94
4.96
Cdh Tj = +7 °C
0.96
0.96
Pdh Tj = 12°C
29.38 kW
28.5 kW
COP Tj = 12°C
6.87
6.16
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
21.74 kW
20.46 kW
COP Tj = Tbiv
1.96
1.6
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
17.95 kW
18.11 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.65
1.43
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
26.65 kW
27.77 kW
Annual energy consumption Qhe
17986 kWh
24781 kWh
Pdh Tj = -15°C (if TOL<-20°C)
17.95
18.11
COP Tj = -15°C (if TOL<-20°C)
1.65
1.43
Cdh Tj = -15 °C
0.9
0.9
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
126 %
Prated
34.1 kW
33.2 kW
SCOP
4.33
3.24
Tbiv
-7 °C
-6 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
30.13 kW
26.60 kW
COP Tj = -7°C
2.81
1.87
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
21.36 kW
18.78 kW
COP Tj = +2°C
4.47
3.26
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
25.09 kW
23.27 kW
COP Tj = +7°C
5.61
4.49
Cdh Tj = +7 °C
0.95
0.98
Pdh Tj = 12°C
29.72 kW
28.35 kW
COP Tj = 12°C
7.27
6.23
Cdh Tj = +12 °C
0.95
0.98
Pdh Tj = Tbiv
30.13 kW
28.13 kW
COP Tj = Tbiv
2.81
2.00
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
28.65 kW
14.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.60
1.10
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.40 kW
19.24 kW
Annual energy consumption Qhe
16247 kWh
21225 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
54.15 kW
51.91 kW
El input
12.83 kW
19.37 kW
COP
4.22
2.68
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
214 %
153 %
Prated
46.8 kW
34.58 kW
SCOP
5.42
3.91
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
46.8 kW
34.58 kW
COP Tj = +2°C
3.36
2.05
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
30.03 kW
22.84 kW
COP Tj = +7°C
5.01
3.5
Cdh Tj = +7 °C
0.9
0.9
Pdh Tj = 12°C
29.25 kW
27.53 kW
COP Tj = 12°C
6.65
5.2
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
46.8 kW
34.58 kW
COP Tj = Tbiv
3.36
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
46.8 kW
34.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.36
2.05
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
11539 kWh
11818 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
141 %
108 %
Prated
29.19 kW
30.28 kW
SCOP
3.6
2.77
Tbiv
-15 °C
-12 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
17.66 kW
18.31 kW
COP Tj = -7°C
3.06
2.28
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
21.8 kW
20.6 kW
COP Tj = +2°C
4.93
3.88
Cdh Tj = +2 °C
0.96
0.96
Pdh Tj = +7°C
25.66 kW
24.5 kW
COP Tj = +7°C
5.92
4.96
Cdh Tj = +7 °C
0.96
0.96
Pdh Tj = 12°C
29.44 kW
28.5 kW
COP Tj = 12°C
6.87
6.16
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
23.81 kW
22.31 kW
COP Tj = Tbiv
1.78
1.63
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
19.99 kW
19.96 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.71
1.47
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
29.19 kW
30.28 kW
Annual energy consumption Qhe
19980 kWh
26981 kWh
Pdh Tj = -15°C (if TOL<-20°C)
19.99
19.96
COP Tj = -15°C (if TOL<-20°C)
1.71
1.47
Cdh Tj = -15 °C
0.9
0.9
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
125 %
Prated
38.6 kW
37.27 kW
SCOP
4.33
3.19
Tbiv
-7 °C
-6 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
34.16 kW
30.48 kW
COP Tj = -7°C
2.76
1.87
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
22.74 kW
20.42 kW
COP Tj = +2°C
4.41
3.17
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
25.15 kW
23.63 kW
COP Tj = +7°C
5.53
4.49
Cdh Tj = +7 °C
0.95
0.98
Pdh Tj = 12°C
29.80 kW
28.56 kW
COP Tj = 12°C
7.15
6.25
Cdh Tj = +12 °C
0.95
0.98
Pdh Tj = Tbiv
34.16 kW
31.53 kW
COP Tj = Tbiv
2.76
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
33.22 kW
15.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.58
1.25
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.40 kW
22.27 kW
Annual energy consumption Qhe
18442 kWh
24126 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
54.15 kW
51.91 kW
El input
12.83 kW
19.37 kW
COP
4.22
2.68
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
214 %
153 %
Prated
46.8 kW
34.58 kW
SCOP
5.42
3.91
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
46.8 kW
34.58 kW
COP Tj = +2°C
3.36
2.05
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
30.03 kW
22.84 kW
COP Tj = +7°C
5.01
3.5
Cdh Tj = +7 °C
0.9
0.9
Pdh Tj = 12°C
29.25 kW
27.53 kW
COP Tj = 12°C
6.65
5.2
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
46.8 kW
34.58 kW
COP Tj = Tbiv
3.36
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
46.8 kW
34.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.36
2.05
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
11539 kWh
11818 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
141 %
108 %
Prated
29.19 kW
30.28 kW
SCOP
3.6
2.77
Tbiv
-15 °C
-12 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
17.66 kW
18.31 kW
COP Tj = -7°C
3.06
2.28
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
21.8 kW
20.6 kW
COP Tj = +2°C
4.93
3.88
Cdh Tj = +2 °C
0.96
0.96
Pdh Tj = +7°C
25.66 kW
24.5 kW
COP Tj = +7°C
5.92
4.96
Cdh Tj = +7 °C
0.96
0.96
Pdh Tj = 12°C
29.44 kW
28.5 kW
COP Tj = 12°C
6.87
6.16
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
23.81 kW
22.31 kW
COP Tj = Tbiv
1.78
1.63
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
19.99 kW
19.96 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.71
1.47
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
29.19 kW
30.28 kW
Annual energy consumption Qhe
19980 kWh
26981 kWh
Pdh Tj = -15°C (if TOL<-20°C)
19.99
19.96
COP Tj = -15°C (if TOL<-20°C)
1.71
1.47
Cdh Tj = -15 °C
0.9
0.9
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
125 %
Prated
38.6 kW
37.27 kW
SCOP
4.33
3.19
Tbiv
-7 °C
-6 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
34.16 kW
30.48 kW
COP Tj = -7°C
2.76
1.87
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
22.74 kW
20.42 kW
COP Tj = +2°C
4.41
3.17
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
25.15 kW
23.63 kW
COP Tj = +7°C
5.53
4.49
Cdh Tj = +7 °C
0.95
0.98
Pdh Tj = 12°C
29.80 kW
28.56 kW
COP Tj = 12°C
7.15
6.25
Cdh Tj = +12 °C
0.95
0.98
Pdh Tj = Tbiv
34.16 kW
31.53 kW
COP Tj = Tbiv
2.76
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
33.22 kW
15.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.58
1.25
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.40 kW
22.27 kW
Annual energy consumption Qhe
18442 kWh
24126 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
54.15 kW
51.91 kW
El input
12.83 kW
19.37 kW
COP
4.22
2.68
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
214 %
153 %
Prated
46.8 kW
34.58 kW
SCOP
5.42
3.91
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
46.8 kW
34.58 kW
COP Tj = +2°C
3.36
2.05
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
30.03 kW
22.84 kW
COP Tj = +7°C
5.01
3.5
Cdh Tj = +7 °C
0.9
0.9
Pdh Tj = 12°C
29.25 kW
27.53 kW
COP Tj = 12°C
6.65
5.2
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
46.8 kW
34.58 kW
COP Tj = Tbiv
3.36
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
46.8 kW
34.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.36
2.05
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
11539 kWh
11818 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
141 %
108 %
Prated
29.19 kW
30.28 kW
SCOP
3.6
2.77
Tbiv
-15 °C
-12 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
17.66 kW
18.31 kW
COP Tj = -7°C
3.06
2.28
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
21.8 kW
20.6 kW
COP Tj = +2°C
4.93
3.88
Cdh Tj = +2 °C
0.96
0.96
Pdh Tj = +7°C
25.66 kW
24.5 kW
COP Tj = +7°C
5.92
4.96
Cdh Tj = +7 °C
0.96
0.96
Pdh Tj = 12°C
29.44 kW
28.5 kW
COP Tj = 12°C
6.87
6.16
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
23.81 kW
22.31 kW
COP Tj = Tbiv
1.78
1.63
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
19.99 kW
19.96 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.71
1.47
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
29.19 kW
30.28 kW
Annual energy consumption Qhe
19980 kWh
26981 kWh
Pdh Tj = -15°C (if TOL<-20°C)
19.99
19.96
COP Tj = -15°C (if TOL<-20°C)
1.71
1.47
Cdh Tj = -15 °C
0.9
0.9
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
125 %
Prated
38.6 kW
37.27 kW
SCOP
4.33
3.19
Tbiv
-7 °C
-6 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
34.16 kW
30.48 kW
COP Tj = -7°C
2.76
1.87
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
22.74 kW
20.42 kW
COP Tj = +2°C
4.41
3.17
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
25.15 kW
23.63 kW
COP Tj = +7°C
5.53
4.49
Cdh Tj = +7 °C
0.95
0.98
Pdh Tj = 12°C
29.80 kW
28.56 kW
COP Tj = 12°C
7.15
6.25
Cdh Tj = +12 °C
0.95
0.98
Pdh Tj = Tbiv
34.16 kW
31.53 kW
COP Tj = Tbiv
2.76
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
33.22 kW
15.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.58
1.25
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.40 kW
22.27 kW
Annual energy consumption Qhe
18442 kWh
24126 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
54.15 kW
51.91 kW
El input
12.83 kW
19.37 kW
COP
4.22
2.68
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
214 %
153 %
Prated
46.8 kW
34.58 kW
SCOP
5.42
3.91
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
46.8 kW
34.58 kW
COP Tj = +2°C
3.36
2.05
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
30.03 kW
22.84 kW
COP Tj = +7°C
5.01
3.5
Cdh Tj = +7 °C
0.9
0.9
Pdh Tj = 12°C
29.25 kW
27.53 kW
COP Tj = 12°C
6.65
5.2
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
46.8 kW
34.58 kW
COP Tj = Tbiv
3.36
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
46.8 kW
34.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.36
2.05
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
11539 kWh
11818 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
141 %
108 %
Prated
29.19 kW
30.28 kW
SCOP
3.6
2.77
Tbiv
-15 °C
-12 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
17.66 kW
18.31 kW
COP Tj = -7°C
3.06
2.28
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
21.8 kW
20.6 kW
COP Tj = +2°C
4.93
3.88
Cdh Tj = +2 °C
0.96
0.96
Pdh Tj = +7°C
25.66 kW
24.5 kW
COP Tj = +7°C
5.92
4.96
Cdh Tj = +7 °C
0.96
0.96
Pdh Tj = 12°C
29.44 kW
28.5 kW
COP Tj = 12°C
6.87
6.16
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
23.81 kW
22.31 kW
COP Tj = Tbiv
1.78
1.63
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
19.99 kW
19.96 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.71
1.47
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
29.19 kW
30.28 kW
Annual energy consumption Qhe
19980 kWh
26981 kWh
Pdh Tj = -15°C (if TOL<-20°C)
19.99
19.96
COP Tj = -15°C (if TOL<-20°C)
1.71
1.47
Cdh Tj = -15 °C
0.9
0.9
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
125 %
Prated
38.6 kW
37.27 kW
SCOP
4.33
3.19
Tbiv
-7 °C
-6 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
34.16 kW
30.48 kW
COP Tj = -7°C
2.76
1.87
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
22.74 kW
20.42 kW
COP Tj = +2°C
4.41
3.17
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
25.15 kW
23.63 kW
COP Tj = +7°C
5.53
4.49
Cdh Tj = +7 °C
0.95
0.98
Pdh Tj = 12°C
29.80 kW
28.56 kW
COP Tj = 12°C
7.15
6.25
Cdh Tj = +12 °C
0.95
0.98
Pdh Tj = Tbiv
34.16 kW
31.53 kW
COP Tj = Tbiv
2.76
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
33.22 kW
15.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.58
1.25
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.40 kW
22.27 kW
Annual energy consumption Qhe
18442 kWh
24126 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
62.2 kW
56.69 kW
El input
15.43 kW
21 kW
COP
4.03
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
209 %
154 %
Prated
50.5 kW
37.7 kW
SCOP
5.29
3.92
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
50.5 kW
37.7 kW
COP Tj = +2°C
3.11
2.03
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
33.39 kW
24.54 kW
COP Tj = +7°C
4.83
3.5
Cdh Tj = +7 °C
0.9
0.9
Pdh Tj = 12°C
29.35 kW
27.53 kW
COP Tj = 12°C
6.58
5.2
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
50.5 kW
37.7 kW
COP Tj = Tbiv
3.11
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
50.5 kW
37.7 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.11
2.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
12748 kWh
12832 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
141 %
106 %
Prated
31.92 kW
33.75 kW
SCOP
3.6
2.73
Tbiv
-15 °C
-12 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
19.55 kW
20.78 kW
COP Tj = -7°C
2.94
2.18
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
21.87 kW
20.6 kW
COP Tj = +2°C
4.86
3.88
Cdh Tj = +2 °C
0.96
0.96
Pdh Tj = +7°C
25.75 kW
24.5 kW
COP Tj = +7°C
5.84
4.96
Cdh Tj = +7 °C
0.96
0.96
Pdh Tj = 12°C
29.54 kW
28.5 kW
COP Tj = 12°C
6.79
6.16
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
26.04 kW
24.87 kW
COP Tj = Tbiv
2
1.69
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
22.21 kW
22.25 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.76
1.39
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
31.92 kW
33.75 kW
Annual energy consumption Qhe
21843 kWh
30489 kWh
Pdh Tj = -15°C (if TOL<-20°C)
22.21
22.25
COP Tj = -15°C (if TOL<-20°C)
1.76
1.39
Cdh Tj = -15 °C
0.9
0.9
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
168 %
124 %
Prated
43 kW
40.32 kW
SCOP
4.28
3.16
Tbiv
-7 °C
-6 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
38.01 kW
33.01 kW
COP Tj = -7°C
2.75
1.86
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
22.78 kW
21.39 kW
COP Tj = +2°C
4.35
3.12
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
25.19 kW
23.63 kW
COP Tj = +7°C
5.44
4.49
Cdh Tj = +7 °C
0.95
0.98
Pdh Tj = 12°C
29.84 kW
28.56 kW
COP Tj = 12°C
7.04
6.25
Cdh Tj = +12 °C
0.95
0.98
Pdh Tj = Tbiv
38.01 kW
34.12 kW
COP Tj = Tbiv
2.75
1.93
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
35.92 kW
16.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.20
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
7.04 kW
24.32 kW
Annual energy consumption Qhe
20714 kWh
26340 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
62.2 kW
56.69 kW
El input
15.43 kW
21 kW
COP
4.03
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
209 %
154 %
Prated
50.5 kW
37.7 kW
SCOP
5.29
3.92
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
50.5 kW
37.7 kW
COP Tj = +2°C
3.11
2.03
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
33.39 kW
24.54 kW
COP Tj = +7°C
4.83
3.5
Cdh Tj = +7 °C
0.9
0.9
Pdh Tj = 12°C
29.35 kW
27.53 kW
COP Tj = 12°C
6.58
5.2
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
50.5 kW
37.7 kW
COP Tj = Tbiv
3.11
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
50.5 kW
37.7 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.11
2.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
12748 kWh
12832 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
141 %
106 %
Prated
31.92 kW
33.75 kW
SCOP
3.6
2.73
Tbiv
-15 °C
-12 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
19.55 kW
20.78 kW
COP Tj = -7°C
2.94
2.18
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
21.87 kW
20.6 kW
COP Tj = +2°C
4.86
3.88
Cdh Tj = +2 °C
0.96
0.96
Pdh Tj = +7°C
25.75 kW
24.5 kW
COP Tj = +7°C
5.84
4.96
Cdh Tj = +7 °C
0.96
0.96
Pdh Tj = 12°C
29.54 kW
28.5 kW
COP Tj = 12°C
6.79
6.16
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
26.04 kW
24.87 kW
COP Tj = Tbiv
2
1.69
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
22.21 kW
22.25 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.76
1.39
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
31.92 kW
33.75 kW
Annual energy consumption Qhe
21843 kWh
30489 kWh
Pdh Tj = -15°C (if TOL<-20°C)
22.21
22.25
COP Tj = -15°C (if TOL<-20°C)
1.76
1.39
Cdh Tj = -15 °C
0.9
0.9
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
168 %
124 %
Prated
43 kW
40.32 kW
SCOP
4.28
3.16
Tbiv
-7 °C
-6 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
38.01 kW
33.01 kW
COP Tj = -7°C
2.75
1.86
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
22.78 kW
21.39 kW
COP Tj = +2°C
4.35
3.12
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
25.19 kW
23.63 kW
COP Tj = +7°C
5.44
4.49
Cdh Tj = +7 °C
0.95
0.98
Pdh Tj = 12°C
29.84 kW
28.56 kW
COP Tj = 12°C
7.04
6.25
Cdh Tj = +12 °C
0.95
0.98
Pdh Tj = Tbiv
38.01 kW
34.12 kW
COP Tj = Tbiv
2.75
1.93
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
35.92 kW
16.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.20
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
7.04 kW
24.32 kW
Annual energy consumption Qhe
20714 kWh
26340 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
62.2 kW
56.69 kW
El input
15.43 kW
21 kW
COP
4.03
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
209 %
154 %
Prated
50.5 kW
37.7 kW
SCOP
5.29
3.92
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
50.5 kW
37.7 kW
COP Tj = +2°C
3.11
2.03
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
33.39 kW
24.54 kW
COP Tj = +7°C
4.83
3.5
Cdh Tj = +7 °C
0.9
0.9
Pdh Tj = 12°C
29.35 kW
27.53 kW
COP Tj = 12°C
6.58
5.2
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
50.5 kW
37.7 kW
COP Tj = Tbiv
3.11
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
50.5 kW
37.7 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.11
2.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
12748 kWh
12832 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
141 %
106 %
Prated
31.92 kW
33.75 kW
SCOP
3.6
2.73
Tbiv
-15 °C
-12 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
19.55 kW
20.78 kW
COP Tj = -7°C
2.94
2.18
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
21.87 kW
20.6 kW
COP Tj = +2°C
4.86
3.88
Cdh Tj = +2 °C
0.96
0.96
Pdh Tj = +7°C
25.75 kW
24.5 kW
COP Tj = +7°C
5.84
4.96
Cdh Tj = +7 °C
0.96
0.96
Pdh Tj = 12°C
29.54 kW
28.5 kW
COP Tj = 12°C
6.79
6.16
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
26.04 kW
24.87 kW
COP Tj = Tbiv
2
1.69
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
22.21 kW
22.25 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.76
1.39
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
31.92 kW
33.75 kW
Annual energy consumption Qhe
21843 kWh
30489 kWh
Pdh Tj = -15°C (if TOL<-20°C)
22.21
22.25
COP Tj = -15°C (if TOL<-20°C)
1.76
1.39
Cdh Tj = -15 °C
0.9
0.9
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
168 %
124 %
Prated
43 kW
40.32 kW
SCOP
4.28
3.16
Tbiv
-7 °C
-6 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
38.01 kW
33.01 kW
COP Tj = -7°C
2.75
1.86
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
22.78 kW
21.39 kW
COP Tj = +2°C
4.35
3.12
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
25.19 kW
23.63 kW
COP Tj = +7°C
5.44
4.49
Cdh Tj = +7 °C
0.95
0.98
Pdh Tj = 12°C
29.84 kW
28.56 kW
COP Tj = 12°C
7.04
6.25
Cdh Tj = +12 °C
0.95
0.98
Pdh Tj = Tbiv
38.01 kW
34.12 kW
COP Tj = Tbiv
2.75
1.93
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
35.92 kW
16.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.20
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
7.04 kW
24.32 kW
Annual energy consumption Qhe
20714 kWh
26340 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
62.2 kW
56.69 kW
El input
15.43 kW
21 kW
COP
4.03
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
209 %
154 %
Prated
50.5 kW
37.7 kW
SCOP
5.29
3.92
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
50.5 kW
37.7 kW
COP Tj = +2°C
3.11
2.03
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
33.39 kW
24.54 kW
COP Tj = +7°C
4.83
3.5
Cdh Tj = +7 °C
0.9
0.9
Pdh Tj = 12°C
29.35 kW
27.53 kW
COP Tj = 12°C
6.58
5.2
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
50.5 kW
37.7 kW
COP Tj = Tbiv
3.11
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
50.5 kW
37.7 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.11
2.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
12748 kWh
12832 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
141 %
106 %
Prated
31.92 kW
33.75 kW
SCOP
3.6
2.73
Tbiv
-15 °C
-12 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
19.55 kW
20.78 kW
COP Tj = -7°C
2.94
2.18
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
21.87 kW
20.6 kW
COP Tj = +2°C
4.86
3.88
Cdh Tj = +2 °C
0.96
0.96
Pdh Tj = +7°C
25.75 kW
24.5 kW
COP Tj = +7°C
5.84
4.96
Cdh Tj = +7 °C
0.96
0.96
Pdh Tj = 12°C
29.54 kW
28.5 kW
COP Tj = 12°C
6.79
6.16
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
26.04 kW
24.87 kW
COP Tj = Tbiv
2
1.69
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
22.21 kW
22.25 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.76
1.39
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
31.92 kW
33.75 kW
Annual energy consumption Qhe
21843 kWh
30489 kWh
Pdh Tj = -15°C (if TOL<-20°C)
22.21
22.25
COP Tj = -15°C (if TOL<-20°C)
1.76
1.39
Cdh Tj = -15 °C
0.9
0.9
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
-99 dB(A)
-99 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
168 %
124 %
Prated
43 kW
40.32 kW
SCOP
4.28
3.16
Tbiv
-7 °C
-6 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
38.01 kW
33.01 kW
COP Tj = -7°C
2.75
1.86
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
22.78 kW
21.39 kW
COP Tj = +2°C
4.35
3.12
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
25.19 kW
23.63 kW
COP Tj = +7°C
5.44
4.49
Cdh Tj = +7 °C
0.95
0.98
Pdh Tj = 12°C
29.84 kW
28.56 kW
COP Tj = 12°C
7.04
6.25
Cdh Tj = +12 °C
0.95
0.98
Pdh Tj = Tbiv
38.01 kW
34.12 kW
COP Tj = Tbiv
2.75
1.93
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
35.92 kW
16.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.20
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
7.04 kW
24.32 kW
Annual energy consumption Qhe
20714 kWh
26340 kWh