Login

Subtype

EVI DC Inverter Heat Pump 50/60 A

Certificate Holder
Power World Machinery Equipment Co. Ltd
No.24, The Fourth Industrial Zone, HouTing Street
Shenzhen
China
Registration number
041-K032-03 / 01
Certification Body
BRE Global Limited
Subtype title
EVI DC Inverter Heat Pump 50/60 A
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,700 kg

Certification Date
18.08.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 09
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

PW050-DKZLRS-A
Configure model
Model name
PW050-DKZLRS-A
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

20.70 kW

19.68 kW

El input

4.58 kW

7.41 kW

COP

4.52

2.66

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

69 dB(A)

73 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

134 %

Prated

16.17 kW

17.01 kW

SCOP

4.45

3.41

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.31 kW

15.05 kW

COP Tj = -7°C

3.53

2.34

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.72 kW

9.20 kW

COP Tj = +2°C

4.36

3.40

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.69 kW

7.50 kW

COP Tj = +7°C

5.44

4.29

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

10.06 kW

8.71 kW

COP Tj = 12°C

6.68

5.69

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

14.31 kW

15.05 kW

COP Tj = Tbiv

3.53

2.34

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.18 kW

13.79 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.97

2.16

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

50 °C

50 °C

Poff

5 W

5 W

PTO

15 W

5 W

PSB

5 W

5 W

PCK

50 W

50 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

3.22 kW

Annual energy consumption Qhe

7507 kWh

10293 kWh

PW060-DKZLRS-A
Configure model
Model name
PW060-DKZLRS-A
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

20.49 kW

21.59 kW

El input

5.85 kW

7.46 kW

COP

3.50

2.89

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

72 dB(A)

75 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

132 %

Prated

17.67 kW

18.25 kW

SCOP

4.45

3.38

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

15.63 kW

16.14 kW

COP Tj = -7°C

3.55

2.20

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

9.53 kW

9.83 kW

COP Tj = +2°C

4.35

3.42

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

9.08 kW

7.82 kW

COP Tj = +7°C

5.44

4.22

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

9.31 kW

9.26 kW

COP Tj = 12°C

6.98

5.65

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

15.63 kW

16.14 kW

COP Tj = Tbiv

3.55

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.17 kW

14.19 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.87

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

50 °C

50 °C

Poff

5 W

5 W

PTO

15 W

15 W

PSB

5 W

5 W

PCK

50 W

50 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.50 kW

4.06 kW

Annual energy consumption Qhe

8198 kWh

11167 kWh