Login

Subtype

EVI DC Inverter Heat Pump 040

Certificate Holder
Power World Machinery Equipment Co. Ltd
No.24, The Fourth Industrial Zone, HouTing Street
Shenzhen
China
Registration number
041-K032-02 / 01
Certification Body
BRE Global Limited
Subtype title
EVI DC Inverter Heat Pump 040
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,600 kg

Certification Date
18.08.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 09
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

PW040-DKZLRS-A
Configure model
Model name
PW040-DKZLRS-A
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.84 kW

8.22 kW

El input

1.69 kW

3.05 kW

COP

4.65

2.69

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

127 %

Prated

7.00 kW

7.19 kW

SCOP

4.46

3.25

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

6.19 kW

6.36 kW

COP Tj = -7°C

2.98

2.39

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.98 kW

4.01 kW

COP Tj = +2°C

4.50

3.28

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.19 kW

4.17 kW

COP Tj = +7°C

5.81

4.06

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.65 kW

4.95 kW

COP Tj = 12°C

7.79

5.62

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.19 kW

6.36 kW

COP Tj = Tbiv

2.98

2.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.74 kW

5.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

50 °C

50 °C

Poff

6 W

6 W

PTO

7 W

7 W

PSB

6 W

6 W

PCK

40 W

40 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.25 kW

1.62 kW

Annual energy consumption Qhe

3244 kWh

4566 kWh