EVI DC Inverter Heat Pump 030

Certificate Holder
Power World Machinery Equipment Co. Ltd
No.24, The Fourth Industrial Zone, HouTing Street
Shenzhen
China
Registration number
041-K032-01 / 01
Certification Body
BRE Global Limited
Subtype title
EVI DC Inverter Heat Pump 030
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,300 kg

Certification Date
18.08.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 09
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

PW030-DKZLRS-A
Configure model
Model name
PW030-DKZLRS-A
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.04 kW

4.99 kW

El input

1.14 kW

1.66 kW

COP

4.42

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

62 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

128 %

Prated

4.13 kW

4.34 kW

SCOP

4.45

3.27

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

3.65 kW

3.84 kW

COP Tj = -7°C

2.75

2.36

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.38 kW

2.45 kW

COP Tj = +2°C

4.65

3.21

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.37 kW

2.72 kW

COP Tj = +7°C

5.80

4.30

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.98 kW

3.00 kW

COP Tj = 12°C

7.80

5.74

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.65 kW

3.84 kW

COP Tj = Tbiv

2.75

2.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.90 kW

4.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.39

1.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

50 °C

50 °C

Poff

5 W

5 W

PTO

6 W

6 W

PSB

5 W

5 W

PCK

30 W

30 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.23 kW

0.14 kW

Annual energy consumption Qhe

1917 kWh

2742 kWh