4,000 kg
Cooling
EN 14511-2
+7°C/+12°C
El input
4.88 kW
Cooling capacity
15.04
EER
3.08
EN 14825
+7°C/+12°C
Pdesignc
15.04 kW
SEER
5.05
Pdc Tj = 35°C
15.04 kW
EER Tj = 35°C
3.08
Pdc Tj = 30°C
10.96 kW
EER Tj = 30°C
4.38
Cdc Tj = 30 °C
1.000
Pdc Tj = 25°C
7.06 kW
EER Tj = 25°C
5.52
Cdc Tj = 25 °C
0.985
Pdc Tj = 20°C
5.54 kW
EER Tj = 20°C
6.80
Cdc Tj = 20 °C
0.977
Poff
22 W
PTO
0 W
PSB
28 W
PCK
0 W
Annual energy consumption Qce
1788 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
17.90 kW
17.25 kW
El input
4.07 kW
5.99 kW
COP
4.40
2.88
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
131 %
Prated
15.00 kW
14.00 kW
SCOP
4.46
3.36
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
12.80 kW
12.50 kW
COP Tj = -7°C
2.83
2.03
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
7.80 kW
7.60 kW
COP Tj = +2°C
4.34
3.34
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
5.80 kW
5.70 kW
COP Tj = +7°C
5.67
4.14
Cdh Tj = +7 °C
0.981
0.990
Pdh Tj = 12°C
6.70 kW
6.60 kW
COP Tj = 12°C
7.94
6.15
Cdh Tj = +12 °C
0.977
0.980
Pdh Tj = Tbiv
12.80 kW
12.50 kW
COP Tj = Tbiv
2.83
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.80 kW
12.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.93
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
19 W
19 W
PTO
22 W
22 W
PSB
19 W
19 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
2.20 kW
1.40 kW
Annual energy consumption Qhe
6720 kWh
8659 kWh