Login

Subtype

DC Inverter Air to Water Heat Pump Unit-R32-19

Certificate Holder
Zhongshan Amitime Electric Co., Ltd
5th Yandong Rd
Zhongshan City - Guangdong
China
Registration number
041-K027-08 / 01
Certification Body
BRE Global Limited
Subtype title
DC Inverter Air to Water Heat Pump Unit-R32-19
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,600 kg

Certification Date
26.08.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 13
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

Outdoor unit: PAVH-19V4FEB, Indoor unit: PAVH-19V4FB/IA
Configure model
Model name
Outdoor unit: PAVH-19V4FEB, Indoor unit: PAVH-19V4FB/IA
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

13.37 kW

13.81 kW

El input

2.72 kW

5.17 kW

COP

4.92

2.67

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

39 dB(A)

Sound power level outdoor

57 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

128 %

Prated

16.19 kW

12.29 kW

SCOP

4.70

3.28

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.32 kW

10.87 kW

COP Tj = -7°C

3.29

2.03

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.77 kW

6.70 kW

COP Tj = +2°C

4.57

3.31

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.09 kW

7.41 kW

COP Tj = +7°C

6.18

4.55

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

9.14 kW

8.74 kW

COP Tj = 12°C

7.86

5.98

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

14.32 kW

10.87 kW

COP Tj = Tbiv

3.29

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.87 kW

9.75 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.01

1.74

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

56 °C

56 °C

Poff

13 W

13 W

PTO

39 W

39 W

PSB

13 W

13 W

PCK

42 W

42 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.32 kW

2.53 kW

Annual energy consumption Qhe

7117 kWh

7746 kWh