1,700 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.32 kW
16.31 kW
El input
3.56 kW
5.64 kW
COP
4.58
2.89
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
67 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
131 %
Prated
15.45 kW
13.03 kW
SCOP
4.55
3.36
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.67 kW
11.53 kW
COP Tj = -7°C
2.68
2.02
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
8.23 kW
7.34 kW
COP Tj = +2°C
4.35
3.12
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.51 kW
4.99 kW
COP Tj = +7°C
6.48
4.66
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
6.53 kW
6.22 kW
COP Tj = 12°C
9.43
7.41
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
13.67 kW
11.53 kW
COP Tj = Tbiv
2.68
2.02
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14.13 kW
10.79 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.47
1.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
98 W
98 W
PTO
98 W
98 W
PSB
98 W
98 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.32 kW
2.24 kW
Annual energy consumption Qhe
7024 kWh
8023 kWh