Login

Subtype

DC Inverter Air to Water Heat Pump Unit-R32-XC 09

Certificate Holder
Zhongshan Amitime Electric Co., Ltd
5th Yandong Rd
Zhongshan City - Guangdong
China
Registration number
041-K027-02 / 01
Certification Body
BRE Global Limited
Subtype title
DC Inverter Air to Water Heat Pump Unit-R32-XC 09
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,150 kg

Certification Date
27.06.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 13
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

PAVH-09V1FXC
Configure model
Model name
PAVH-09V1FXC
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.82 kW

7.91 kW

El input

2.05 kW

2.87 kW

COP

4.30

2.76

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

129 %

Prated

8.49 kW

7.45 kW

SCOP

4.53

3.29

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.51 kW

6.59 kW

COP Tj = -7°C

2.99

1.93

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.60 kW

4.13 kW

COP Tj = +2°C

4.44

3.35

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.59 kW

4.32 kW

COP Tj = +7°C

6.27

4.64

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

5.20 kW

5.14 kW

COP Tj = 12°C

8.10

6.24

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.51 kW

6.59 kW

COP Tj = Tbiv

2.99

1.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.90 kW

6.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

1.68

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

58 °C

58 °C

Poff

8 W

8 W

PTO

32 W

32 W

PSB

8 W

8 W

PCK

41 W

41 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.59 kW

1.22 kW

Annual energy consumption Qhe

3874 kWh

4675 kWh