0,750 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.30 kW
2.80 kW
El input
0.64 kW
0.85 kW
COP
5.20
3.30
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
202 %
159 %
Prated
4.00 kW
3.60 kW
SCOP
5.11
4.04
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
4.02 kW
3.63 kW
COP Tj = +2°C
3.00
2.11
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.54 kW
2.41 kW
COP Tj = +7°C
6.15
3.79
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
1.23 kW
1.51 kW
COP Tj = 12°C
5.26
5.26
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
4.02 kW
3.63 kW
COP Tj = Tbiv
3.00
2.11
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.02 kW
3.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.00
2.11
WTOL
75 °C
75 °C
Poff
0 W
0 W
PTO
10 W
10 W
PSB
8 W
8 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1045 kWh
1191 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
146 %
120 %
Prated
4.50 kW
4.30 kW
SCOP
3.72
3.07
Tbiv
-12 °C
-12 °C
TOL
-15 °C
-15 °C
Pdh Tj = -7°C
2.73 kW
2.64 kW
COP Tj = -7°C
3.69
2.79
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
1.64 kW
1.57 kW
COP Tj = +2°C
4.95
3.87
Cdh Tj = +2 °C
0.970
0.980
Pdh Tj = +7°C
1.10 kW
1.27 kW
COP Tj = +7°C
4.73
4.64
Cdh Tj = +7 °C
0.960
0.960
Pdh Tj = 12°C
1.25 kW
1.20 kW
COP Tj = 12°C
5.47
5.02
Cdh Tj = +12 °C
0.960
0.960
Pdh Tj = Tbiv
3.29 kW
3.07 kW
COP Tj = Tbiv
3.17
2.47
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.32 kW
3.09 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.09
2.40
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
75 °C
75 °C
Poff
0 W
0 W
PTO
10 W
10 W
PSB
8 W
8 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.50 kW
4.30 kW
Annual energy consumption Qhe
2983 kWh
3458 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.32
3.09
COP Tj = -15°C (if TOL<-20°C)
3.09
2.40
Cdh Tj = -15 °C
1.000
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
135 %
Prated
4.10 kW
4.00 kW
SCOP
4.45
3.45
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.69 kW
3.47 kW
COP Tj = -7°C
2.96
2.21
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.26 kW
2.18 kW
COP Tj = +2°C
4.63
3.46
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
1.50 kW
1.37 kW
COP Tj = +7°C
5.61
4.46
Cdh Tj = +7 °C
0.97
0.97
Pdh Tj = 12°C
1.34 kW
1.45 kW
COP Tj = 12°C
5.79
5.57
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
3.69 kW
3.47 kW
COP Tj = Tbiv
2.96
2.21
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.63 kW
3.34 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.83
2.07
WTOL
75 °C
75 °C
Poff
0 W
0 W
PTO
10 W
10 W
PSB
8 W
8 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.47 kW
0.66 kW
Annual energy consumption Qhe
1902 kWh
2396 kWh