Login

Subtype

ECL-BT-300

Certificate Holder
ECL Nexus
13, Boulevard Pereire
75017 Paris
France
Registration number
ICIM-PDC-000148
Certification Body
ICIM S.p.A.
Subtype title
ECL-BT-300
Driving energy
Electricity
Heat Pump Type
Heat Pump for Domestic Hot Water (DHW)
Refrigerant
R134a
Mass of Refrigerant

0,920 kg

Certification Date
20.05.2022
Testing basis
V8
Generate PDF Export model CSV
  • Number of models 3

Models

ECLBT300X.01
Configure model
Model name
ECLBT300X.01
Units
Indoor
Climate zone (for heating)
n/a
Heat Source
Outdoor Air
Any additional heat sources
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
No

Domestic Hot Water (DHW)

Average Climate

EN 12102-2

Sound power level indoor

58 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

118 %

COP

2.85

Heating up time

9:53 h:min

Standby power input

40.0 W

Reference hot water temperature

55.0 °C

Mixed water at 40°C

390 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed

ECLBT300S.01
Configure model
Model name
ECLBT300S.01
Units
Indoor
Climate zone (for heating)
n/a
Heat Source
Outdoor Air
Any additional heat sources
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
No

Domestic Hot Water (DHW)

Average Climate

EN 12102-2

Sound power level indoor

58 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

118 %

COP

2.85

Heating up time

9:53 h:min

Standby power input

40.0 W

Reference hot water temperature

55.0 °C

Mixed water at 40°C

390 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed

ECLBT300D.01
Configure model
Model name
ECLBT300D.01
Units
Indoor
Climate zone (for heating)
n/a
Heat Source
Outdoor Air
Any additional heat sources
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
No

Domestic Hot Water (DHW)

Average Climate

EN 12102-2

Sound power level indoor

58 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

118 %

COP

2.85

Heating up time

9:53 h:min

Standby power input

40.0 W

Reference hot water temperature

55.0 °C

Mixed water at 40°C

390 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed