10,800 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
77.96 kW
81.06 kW
El input
18 kW
26.49 kW
COP
4.33
3.06
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
199 %
154 %
Prated
77.96 kW
81.06 kW
SCOP
5.16
4.05
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
68.96 kW
71.71 kW
COP Tj = -7°C
4.51
3.3
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
41.94 kW
42.2 kW
COP Tj = +2°C
5.26
4.23
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
41.86 kW
42.25 kW
COP Tj = +7°C
5.39
4.53
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
41.78 kW
42.29 kW
COP Tj = 12°C
5.52
4.8
Cdh Tj = +12 °C
1.00
1.00
Pdh Tj = Tbiv
77.96 kW
81.06 kW
COP Tj = Tbiv
4.33
3.06
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
77.96 kW
81.06 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.33
3.06
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
68 °C
68 °C
Poff
9 W
9 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
31189 kWh
41390 kWh