Login

Subtype

R32 THERMAV IWT(2ND) 5,7,9kW

Certificate Holder
LG Electronics Inc.
84, Wanam-ro, seongsan-gu
51554 Changwon-si
South Korea
Registration number
011-1W0526
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
R32 THERMAV IWT(2ND) 5,7,9kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,500 kg

Certification Date
29.04.2022
Testing basis
European KEYMARK Scheme for Heat Pumps Rev. 9 (as of 2021-03)
Generate PDF Export model CSV
  • Number of models 3

Models

HU051MR U44 / HN0913T NK0
Configure model
Model name
HU051MR U44 / HN0913T NK0
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.50 kW

5.50 kW

El input

1.12 kW

2.04 kW

COP

4.90

2.70

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

126 %

Prated

5.50 kW

6.00 kW

SCOP

4.65

3.23

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.90 kW

5.30 kW

COP Tj = -7°C

2.80

2.05

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.00 kW

3.20 kW

COP Tj = +2°C

4.50

3.10

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.20 kW

3.00 kW

COP Tj = +7°C

6.40

4.50

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.60 kW

3.60 kW

COP Tj = 12°C

9.20

6.80

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.50 kW

5.30 kW

COP Tj = Tbiv

2.50

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.50 kW

5.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.50

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

30 W

30 W

Supplementary Heater: Type of energy input

n/a

Electricity

Supplementary Heater: PSUP

0.00 kW

0.90 kW

Annual energy consumption Qhe

2444 kWh

3837 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

133 %

COP

3.15

Heating up time

1:44 h:min

Standby power input

30.0 W

Reference hot water temperature

52.0 °C

Mixed water at 40°C

250 l

HU071MR U44 / HN0913T NK0
Configure model
Model name
HU071MR U44 / HN0913T NK0
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.00 kW

5.50 kW

El input

1.43 kW

2.04 kW

COP

4.90

2.70

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

126 %

Prated

5.80 kW

6.00 kW

SCOP

4.65

3.23

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.10 kW

5.30 kW

COP Tj = -7°C

2.80

2.05

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.10 kW

3.20 kW

COP Tj = +2°C

4.50

3.10

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.40 kW

3.00 kW

COP Tj = +7°C

6.50

4.50

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.80 kW

3.60 kW

COP Tj = 12°C

9.00

6.80

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.80 kW

5.30 kW

COP Tj = Tbiv

2.50

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.80 kW

5.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.50

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

30 W

30 W

Supplementary Heater: Type of energy input

n/a

Electricity

Supplementary Heater: PSUP

0.00 kW

0.90 kW

Annual energy consumption Qhe

2575 kWh

3837 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

133 %

COP

3.15

Heating up time

1:44 h:min

Standby power input

30.0 W

Reference hot water temperature

52.0 °C

Mixed water at 40°C

250 l

HU091MR U44 / HN0913T NK0
Configure model
Model name
HU091MR U44 / HN0913T NK0
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

5.50 kW

El input

1.94 kW

2.04 kW

COP

4.65

2.70

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

126 %

Prated

6.00 kW

6.00 kW

SCOP

4.65

3.23

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.30 kW

5.30 kW

COP Tj = -7°C

2.75

2.05

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.20 kW

3.20 kW

COP Tj = +2°C

4.50

3.10

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.30 kW

3.00 kW

COP Tj = +7°C

6.50

4.50

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.80 kW

3.60 kW

COP Tj = 12°C

9.00

6.80

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.00 kW

5.30 kW

COP Tj = Tbiv

2.45

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.00 kW

5.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.45

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

30 W

30 W

Supplementary Heater: Type of energy input

n/a

Electricity

Supplementary Heater: PSUP

0.00 kW

0.90 kW

Annual energy consumption Qhe

2666 kWh

3837 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

140 %

COP

3.40

Heating up time

1:44 h:min

Standby power input

30.0 W

Reference hot water temperature

52.0 °C

Mixed water at 40°C

250 l